Information:
Procedure For Protective Relaying Programming
Note: Service Mode cannot be accessed when the engine control switch (ECS) is in the AUTO position.Note: An active shutdown fault is indicated by a FLASHING shutdown indicator. An active shutdown fault must be made inactive in order to access service mode. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the shutdown fault must no longer be occurring. The fault must be corrected. The ECS must be returned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, the GSC+ does not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP 4" is showing on the lower display. For more information, see System Operation, "Password Entry OP3".
Press "CROLL UP" key two times. "OP5-1" is showing on the lower display.
Press "SELECT" key once. "P101" is showing. "P101" is followed by the value of the setpoint.
Press the "SCROLL UP" key or the "SCROLL DOWN" key. The next setpoint is showing with the setpoint value. Repeat this step until the desired setpoint is showing.
Press "SELECT" key. The value of the setpoint is flashing.
Press the "SCROLL UP" or the "SCROLL DOWN" key in order to adjust the value of the setpoint.Note: In order to rapidly scroll through a large range of values, press and hold the appropriate "SCROLL" key.
Press "ENTER" key. The value of the setpoint stops flashing. Repeat steps 4, 5, 6 and 7 until all the desired setpoints are adjusted.
Press "EXIT" key. "OP 1" is showing on the lower display.
Press "EXIT" key. The display returns to normal mode.
Table 1
OP5-1 Setpoints (1) - Protective Relaying Programming    
Setpoint    Name    Description    Range Of Value    Factory Default    
P101     Overvoltage Alarm Enable     The GSC+ enables the generator alarm function or the GSC+disables the generator alarm function.     0 - disabled
1 - enabled     1    
P102     Overvoltage Alarm Threshold     Voltage the GSC+ uses to issue an overvoltage alarm.     100 to 125% of nameplate voltage in increments of 1%     105%    
P103     Overvoltage Alarm Time Delay     Amount of time the GSC+ waits before issuing an overvoltage alarm.     0 to 120 seconds (2) in increments of 1     10 seconds    
P104     Overvoltage Shutdown Enabled     The GSC+ enables or disables the generator overvoltage shutdown function.     0 - disabled
1 - enabled     1    
P105     Overvoltage Shutdown Threshold     Voltage the GSC+ uses to issue an overvoltage shutdown.     100 to 125% of nameplate voltage in increments of 1%     110%    
P106     Overvoltage Shutdown Time Delay     Amount of time the GSC+ waits before inssuing an overvoltage shutdown.     0 to 120 seconds (2) in increments of 1     10 seconds    
P107     Undervoltage Alarm Enable     The GSC+ enables or disables the generator undervoltage alarm function.     0 - disabled
1 - enabled     1    
P108     Undervoltage Alarm Threshold     Voltage the GSC+ uses to issue an undervoltage alarm.     60 to 100% of nameplate voltage in increments of 1%     90%    
P109     Undervoltage Alarm Time Delay     Amount of time the GSC+ waits before inssuing an undervoltage alarm.     0 to 120 seconds (2) in increments of 1     10 seconds    
P110     Undervoltage Shutdown Enable     The GSC+ enables or disables the generator undervoltageshutdown function.     0 - disabled
1 - enabled     1    
P111     Undervoltage Shutdown Threshold     Voltage the GSC+ uses to issue an undervoltage shutdown.     60 to 100% of nameplate voltage in increments of 1%     85%    
P112     Undervoltage Shutdown Time Delay     Amount of time the GSC+ waits before issuing an undervoltage shutdown.     0 to 120 seconds (2) in increments of 1     15 seconds    
P113     Overfrequency Alarm Enable     The GSC+ enables or disables the generator overfrequency alarm function.     0 - disabled
1 - enabled     1    
P114     Overfrequency Alarm Threshold     Frequency that the GSC+ uses to issue an overfrequency alarm.     50 to 60, for 50 Hz GEN
60 to 70, for 60 Hz Gen
400 to 480, for 400 Hz Gen     53 Hz
63 Hz
422 Hz    
P115     Overfrequency Alarm Time Delay     Amount of time the GSC+ waits before issuing an overfrequency alarm.     0 to 120 seconds (2) in increments of 1     10 seconds    
P116     Overfrequency Shutdown Enable     The GSC+ enables or disables the generator overfrequency shutdown function.     0 - disabled
1 - enabled     1    
P117     Overfrequency Shutdown Threshold     Frequency the GSC+ uses to issue an overfrequency shutdown.     50 to 60, for 50 Hz Gen
60 to 70, for 60 Hz Gen
400 to 480, for 400 Hz Gen     55Hz
63 Hz
422 Hz    
Note: Service Mode cannot be accessed when the engine control switch (ECS) is in the AUTO position.Note: An active shutdown fault is indicated by a FLASHING shutdown indicator. An active shutdown fault must be made inactive in order to access service mode. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the shutdown fault must no longer be occurring. The fault must be corrected. The ECS must be returned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, the GSC+ does not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP 4" is showing on the lower display. For more information, see System Operation, "Password Entry OP3".
Press "CROLL UP" key two times. "OP5-1" is showing on the lower display.
Press "SELECT" key once. "P101" is showing. "P101" is followed by the value of the setpoint.
Press the "SCROLL UP" key or the "SCROLL DOWN" key. The next setpoint is showing with the setpoint value. Repeat this step until the desired setpoint is showing.
Press "SELECT" key. The value of the setpoint is flashing.
Press the "SCROLL UP" or the "SCROLL DOWN" key in order to adjust the value of the setpoint.Note: In order to rapidly scroll through a large range of values, press and hold the appropriate "SCROLL" key.
Press "ENTER" key. The value of the setpoint stops flashing. Repeat steps 4, 5, 6 and 7 until all the desired setpoints are adjusted.
Press "EXIT" key. "OP 1" is showing on the lower display.
Press "EXIT" key. The display returns to normal mode.
Table 1
OP5-1 Setpoints (1) - Protective Relaying Programming    
Setpoint    Name    Description    Range Of Value    Factory Default    
P101     Overvoltage Alarm Enable     The GSC+ enables the generator alarm function or the GSC+disables the generator alarm function.     0 - disabled
1 - enabled     1    
P102     Overvoltage Alarm Threshold     Voltage the GSC+ uses to issue an overvoltage alarm.     100 to 125% of nameplate voltage in increments of 1%     105%    
P103     Overvoltage Alarm Time Delay     Amount of time the GSC+ waits before issuing an overvoltage alarm.     0 to 120 seconds (2) in increments of 1     10 seconds    
P104     Overvoltage Shutdown Enabled     The GSC+ enables or disables the generator overvoltage shutdown function.     0 - disabled
1 - enabled     1    
P105     Overvoltage Shutdown Threshold     Voltage the GSC+ uses to issue an overvoltage shutdown.     100 to 125% of nameplate voltage in increments of 1%     110%    
P106     Overvoltage Shutdown Time Delay     Amount of time the GSC+ waits before inssuing an overvoltage shutdown.     0 to 120 seconds (2) in increments of 1     10 seconds    
P107     Undervoltage Alarm Enable     The GSC+ enables or disables the generator undervoltage alarm function.     0 - disabled
1 - enabled     1    
P108     Undervoltage Alarm Threshold     Voltage the GSC+ uses to issue an undervoltage alarm.     60 to 100% of nameplate voltage in increments of 1%     90%    
P109     Undervoltage Alarm Time Delay     Amount of time the GSC+ waits before inssuing an undervoltage alarm.     0 to 120 seconds (2) in increments of 1     10 seconds    
P110     Undervoltage Shutdown Enable     The GSC+ enables or disables the generator undervoltageshutdown function.     0 - disabled
1 - enabled     1    
P111     Undervoltage Shutdown Threshold     Voltage the GSC+ uses to issue an undervoltage shutdown.     60 to 100% of nameplate voltage in increments of 1%     85%    
P112     Undervoltage Shutdown Time Delay     Amount of time the GSC+ waits before issuing an undervoltage shutdown.     0 to 120 seconds (2) in increments of 1     15 seconds    
P113     Overfrequency Alarm Enable     The GSC+ enables or disables the generator overfrequency alarm function.     0 - disabled
1 - enabled     1    
P114     Overfrequency Alarm Threshold     Frequency that the GSC+ uses to issue an overfrequency alarm.     50 to 60, for 50 Hz GEN
60 to 70, for 60 Hz Gen
400 to 480, for 400 Hz Gen     53 Hz
63 Hz
422 Hz    
P115     Overfrequency Alarm Time Delay     Amount of time the GSC+ waits before issuing an overfrequency alarm.     0 to 120 seconds (2) in increments of 1     10 seconds    
P116     Overfrequency Shutdown Enable     The GSC+ enables or disables the generator overfrequency shutdown function.     0 - disabled
1 - enabled     1    
P117     Overfrequency Shutdown Threshold     Frequency the GSC+ uses to issue an overfrequency shutdown.     50 to 60, for 50 Hz Gen
60 to 70, for 60 Hz Gen
400 to 480, for 400 Hz Gen     55Hz
63 Hz
422 Hz    