930403-0800 Tohatsu NYLON NUT, 8P - 1.25


930403-0800 NYLON NUT, 8P - 1.25 Tohatsu M115A2, M120A2, M140A2, M15D2, M18E2, M40D2, M40D2, M40D2, M50D2, M60C, M70C, M9.9D2, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD90C2, MFS2.5B, NYLON
930403-0800 NYLON NUT, 8P - 1.25 Tohatsu
Rating:
48

Buy NYLON NUT, 8P - 1.25 930403-0800 Tohatsu genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$6.99
 

31-05-2020
0.13[0.00] Pounds
-: -
Nylon Nut
Genuine OEM Tohatsu Part || OEM Nylon Nut || Part Number: 930403-0800 || May not include original package.
Number on catalog scheme: 30
 

Tohatsu entire parts catalog list:

M115A2 2003,2004,2005
M120A2 2003
M140A2 2003,2004,2005
M15D2 2003
M18E2 2003
M40D2 2003
M40D2 2004
M40D2 2005
M50D2 2003
M60C 2003
M70C 2003
M9.9D2 2003
MD115A 2006,2007,2008,2009,2010,2011
MD115A2 2010,2012,2013,2014
MD40A 2003
MD40B 2003,2004,2005,2007,2008,2009,2010,2011
MD40B 2006
MD40B2 2010
MD40B2 2011,2012,2013,2014
MD50A 2003
MD50B 2003
MD50B 2004,2005,2007,2008,2009,2010,2011
MD50B 2006
MD50B2 2010
MD50B2 2011,2012,2013,2014
MD70B 2003,2004,2005,2007,2008,2009
MD70B 2006
MD70B 2010
MD75C2 2010,2011,2012,2013,2014
MD90B 2003,2004,2005,2007,2008,2009
MD90B 2006
MD90B 2010
MD90C2 2010,2011,2012,2013,2014
MFS2.5B 2009
MFS2.5B 2010
MFS2.5B 2011,2012,2013,2014
MFS25B 2010
MFS25B 2011,2012,2013,2014
MFS2B 2009
MFS3.5B 2009
MFS3.5B 2010,2011,2012,2014
MFS3.5B 2013
MFS30B 2010
MFS4B 2010
MFS4C 2011,2012,2013,2014
MFS5B 2010
MFS5C 2011,2012,2013,2014
MFS6B 2010
MFS6C 2011,2012,2013,2014
MFS8A2 2004,2005
MFS8A3 2006
MFS8A3 2007,2008,2009
MFS8A3 2010
MFS8A3 2011,2012,2013,2014
MFS9.8A2 2004,2005
MFS9.8A3 2006
MFS9.8A3 2007,2008,2009
MFS9.8A3 2010
MFS9.8A3 2011,2012,2013,2014

Information:


Illustration 1 g00487968
System Schematic For Generator Fault Relay (GFR)The GSC+ uses the generator fault relay (GFR) to activate the shunt trip coil of the optional circuit breaker during a shutdown fault. This circuit breaker takes the generator off the line during a shutdown fault. The GFR is located within the relay module. The optional circuit breaker is located in the generator housing and the shunt trip coil is located within the circuit breaker.Note: Whenever the GSC+ activates the GFR, "K2" is shown on the lower display. "K2" is also shown on the lower display when the GSC+ attempts to activate the GFR. When the GFR is not activated, "K2" is not shown.ProcedureThe possible cause of this diagnostic code is an open coil or a shorted coil of the GFR.The following response is the system response to this fault while the GFR is activated:
If a CID 442 occurs, then there is no effect on the system because the optional circuit breaker is already open. Also, the shutdown mode is functioning. The generator is already off the line.The following response is the system response to this fault while the GFR is not activated and a shutdown fault occurs:
If a CID 442 occurs, then the GFR cannot activate the shunt trip coil of the optional circuit breaker. The generator remains on-line.The GSC+ treats a CID 442 as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed. When the ECS is in any position except the OFF/RESETposition, the active alarm faults are shown. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the status of the diagnostic code (Active/Inactive).
Turn the ECS to OFF/RESET and then turn the ECS to STOP.
Press the alarm codes key.
Observe the upper display. Check that the diagnostic code is showing.
If the diagnostic code is not showing, enter the service mode. View the fault log (OP1). Check that the diagnostic code is showing. Expected Result: A CID 442 FMI 12 is showing as a active fault or an inactive fault. Results:
OK: A CID 442 FMI 12 has not occurred. The fault is NOT active and the fault is NOT inactive. STOP.
NOT OK: A CID 442 FMI 12 is active or inactive. Proceed to 2.
Check internal cable of relay module. Note: Only open the relay module in a dry environment. If the inspection takes more than twenty minutes replace the desiccant bag in the GSC+ housing. See Testing And Adjusting, "Relay Module - Replace".
Turn the ECS to OFF/RESET.
Temporarily, remove the relay module from the GSC+. See Testing And Adjusting, "Relay Module Replace".
Check the cable that attaches the relay module to the GSC+. Expected Result: The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged. Results:
OK: Reassemble the relay module to the GSC+. Proceed to 3.
NOT OK: If the connector clamp is missing, replace the connector clamp. If the cable is damaged, replace the GSC+. STOP.
Perform a functional check for the GFR.
Turn the ECS to OFF/RESET.
Disconnect all wires from RM-22 of the relay module.
At the relay module, measure the resistance from RM-22 to RM-7. Resistance should be greater than 5000 ohms.
Turn the ECS to STOP and push in the emergency stop button.
At the relay module, measure the resistance from RM-22 to RM-7. Resistance should be less than 5 ohms.Expected Result: For 3.c, the resistance should be greater than 5000 ohms. For 3.e, the resistance should be less than 5 ohms.Results:
OK: There was probably a poor connection.and this procedure corrected it. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". STOP.
NOT OK: Either one of the resistance measurements are NOT correct. The relay module is faulty. Replace the relay module. See Testing And Adjusting, "Relay Module - Replace". STOP.


Parts nylon Tohatsu:

930403-0300
 
930403-0300 NYLON NUT, 3P 0.5
MFS4B, MFS5A2, MFS5B, MFS5B, MFS6A2, MFS6B, MFS6B
930406-0400
 
930406-0400 NYLON NUT, 4P-0.7
M120A2, M140A2, M15D2, M18E2, M25C3, M30A4, M40C, M40D2, M40D2, M40D2, M50D2, M9.9D2, MD40A, MD40B, MD50A, MD50B, MD50B, MFS15B2, MFS18B2, MFS25A, MFS25B, MFS30A, MFS30B, MFS8A, MFS8A2, MFS9.8A, MFS9.8A2, MFS9.9B2
346-62124-0
 
346-62124-0 NYLON NUT, 7/8
M120A2, M140A2, M15D2, M18E2, M25C3, M30A4, M40C, M40D2, M40D2, M40D2, M50D2, M60C, M70C, M9.9D2, MD40A, MD40B, MD50A, MD50B, MD50B, MD70B, MD70B, MD90B, MD90B, MFS15B2, MFS15B2, MFS18B2, MFS18B2, MFS25A, MFS30A, MFS8A2, MFS8A3, MFS9.8A2, MFS9.8A3, M
332-01121-1
 
332-01121-1 NYLON BALL, 3/16
M15D2, M18E2, M9.9D2
353-84918-0
 
353-84918-0 NYLON NUT, 3/8
M115A2, M120A2, M140A2, M15D2, M18E2, M40C, M40D2, M40D2, M40D2, M50D2, M60C, M70C, M9.9D2, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD90C2, MF
930403-0600
 
930403-0600 NYLON NUT, 6P - 1.0
M115A2, M15D2, M18E2, M25C3, M30A4, M40C, M9.9D2, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD75C2, MD90B, MD90C2, MFS15C, MFS20C, MFS25B, MFS25B, MFS30B
3V5-62442-0
 
3V5-62442-0 NYLON NUT (2T), M8-P1.25
MFS15B2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS18B2, MFS20C, MFS20C, MFS25A, MFS25B, MFS30A, MFS30B, MFS8A3, MFS8A3, MFS8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3, MFS9.9B2, MFS9.9B2, MFS9.9C
930403-1000
 
930403-1000 NYLON NUT
M115A2, M120A2, M140A2, M25C3, M30A4, M40C, M60C, M70C, MD115A, MD115A2, MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD90C2, MFS15B2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS18B2, MFS20C, MFS20C, MFS9.9B2, MFS9.9B2, MFS9.9C
Back to top