3T5-10025-0 Tohatsu PISTON RING


3T5-10025-0 PISTON RING Tohatsu MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD70B, MD90B, MD90B, MD90B PISTON
3T5-10025-0 PISTON RING Tohatsu
Rating:
28

Buy PISTON RING 3T5-10025-0 Tohatsu genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$13.64
 

29-07-2019
13 Hundredths Pounds
Tohatsu: Tohatsu
Piston Ring
Genuine Tohatsu Part || OEM Piston Ring || Part Number: 3T5-10025-0
Number on catalog scheme: 1-11
 

Compatible models:

Tohatsu entire parts catalog list:

MD40A 2003
MD40B 2003,2004,2005,2007,2008,2009,2010,2011
MD40B 2006
MD40B2 2010
MD40B2 2011,2012,2013,2014
MD50A 2003
MD50B 2003
MD50B 2004,2005,2007,2008,2009,2010,2011
MD50B 2006
MD50B2 2010
MD50B2 2011,2012,2013,2014
MD70B 2003,2004,2005,2007,2008,2009
MD70B 2006
MD70B 2010
MD90B 2003,2004,2005,2007,2008,2009
MD90B 2006
MD90B 2010

Information:


Table 1
Alternative     Default    
"J1/P1:10"
"J1/P1:12"
"J1/P1:13"     "None"    "Engine Shutdown Output"
Output 2, output 3 or output 4 is available for the connection of an engine shutdown output relay that is used to shut down the vehicle electrical system after the idle timer has expired. The "Engine Shutdown Output" can be programmed to J1/P1:10, to J1/P1:12 or to J1/P1:13. The "Engine Shutdown Output" comes on after the engine runs for more than three seconds. The "Engine Shutdown Output" turns off when the engine rpm is at least 100 rpm below the low idle rpm for more than three seconds.
Table 2
Alternative     Default    
"J1/P1:10"
"J1/P1:12"
"J1/P1:13"     "None"    "Auxiliary Brake"
The auxiliary brake output is for use with a BrakeSaver or other aftermarket braking devices. Output 3 is available for the connection of an auxiliary brake relay. This parameter ("Auxiliary Brake") must be programmed to J1/P1:12. Operation of the auxiliary brake and the relay is inhibited during undesirable engine operating conditions. The time period of fueling the engine is an undesirable engine operating condition.
Table 3
Alternative     Default    
"J1/P1:12"     "None"    "Starting Aid Output"
Output 2, output 3 or output 4 is available for the connection of the starting aid relay or the starting aid solenoid. If a starting aid switch is not used, the starting aid output will turn on automatically when operating conditions require the use of a starting aid. If the "Starting Aid On/Off Switch" parameter is programmed and a switch connected to the corresponding switch input, the starting aid output will not function when the switch is in the OFF position.
Table 4
Alternatives    Default    
"J1/P1:10"
"J1/P1:12"
"J1/P1:13"     "None"    "Air Inlet Shutoff Relay Control"
The air inlet shutoff is available for certain engine ratings that operate in areas with large amounts of combustible gases. The air inlet shutoff will protect the engine from an engine overspeed when these gases are present. If this option is installed, the "Air Inlet Shutoff Relay Control" cannot be turned off. J1/P1:62 must be connected to the +Battery in order for the air inlet shutoff to operate. If a neutral switch is installed in the vehicle, the neutral switch must be connected to J1/P1:62. The air inlet shutoff will only operate when the transmission is in neutral.
Table 5
Alternatives    Default    
"J2/P2:13"     "None"    "Fan Control Type"
If the ECM is used to operate the cooling fan, this parameter must be programmed to "On/Off", to "Three-Speed Fan", or to "Variable Speed Fan Option S". This parameter must be programmed to "None" if the ECM is not operating the cooling fan relay or the cooling fan solenoid.
Table 6
Alternative     Default    
"On/Off"
"Three-Speed Fan"
"Variable Speed Fan Option S"     "None"    "PTO Active Output"
The "PTO Active Output" parameter allows the use of an output when the engine is in PTO mode. The PTO switch must be on in order for the "PTO Active Output" to function. The "PTO Active Output" will stay active until there is a kickout of PTO mode or the PTO switch is turned to the OFF position.
Table 7
Alternative     Default    
"J1/P1:19"     "None"    


Parts piston Tohatsu:

3T5-87330-1
 
3T5-87330-1 PISTON & CONNECTING ROD
MD40A, MD40B, MD40B, MD50A, MD50B, MD50B, MD50B, MD70B, MD70B, MD70B, MD90B, MD90B, MD90B
3T5-00015-0
 
3T5-00015-0 PISTON RING 2ND (0.5MM O/S)
MD40A, MD40B, MD40B, MD50A, MD50B, MD50B, MD50B
3B7-87124-1
 
3B7-87124-1 PISTON RING SET (0.5MM O/S)
MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD90C2
3B7-00014-0
 
3B7-00014-0 PISTON RING 1ST (0.5MM O/S)
MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD90C2
3B7-00015-0
 
3B7-00015-0 PISTON RING 2ND (0.5MM O/S)
MD70B, MD70B, MD70B, MD90B, MD90B, MD90B
3T1-00024-0
 
3T1-00024-0 PISTON PIN CLIP
M115A2, MD115A, MD115A2, MD70B, MD75C2, MD90B, MD90C2
3GF-00004-1
3GF-00001-1
Back to top