Table 1
Diagnostic Codes Table    
Description     Conditions which Generate this Code     System Response    
338-5 Engine Pre-Lube Pump Relay current below normal     The engine's Electronic Control Module (ECM) detects an open in the circuit for the engine prelubrication relay.
The ECM detects a short to battery voltage in the circuit for the prelubrication relay.     The code is logged.    
338-6 Engine Pre-Lube Pump Relay current above normal     The ECM detects a short in the circuit for the prelubrication relay.    When the ECM receives a request for starting the engine the ECM has the ability to automatically lubricate the engine before the engine is cranked. The ECM controls a motor that drives a prelubrication oil pump. This motor will drive the pump until one of the following conditions are met:
The engine oil pressure reaches the desired level for the prelubrication.
The time that is programmed for the configuration parameter "Prelube Duration" has elapsed.
The operator activates the prelube override switch.Note: If the configuration parameter "Prelube Duration" is set to zero seconds, the ECM will skip the process of prelubrication. The ECM will begin cranking the engine immediately. Refer to Troubleshooting, "Configuration Parameters" for the available range and default setting of this parameter.An override for the prelubrication system is available in Caterpillar Electronic Technician (ET). The override allows the technician to activate the prelubrication system for service and testing. The test is functional only when the engine speed is zero rpm. The test is accessed by selecting the following menus on Cat ET:
"Diagnostics"
"Diagnostic Tests"
"Override Parameters"
Illustration 1 g01408611
Schematic for the prelubrication systemTest Step 1. Inspect the Electrical Connectors and the Wiring
Illustration 2 g01409094
Location of the connectors for the engine prelube system (rear engine view) (1) J1/P1 ECM connectors (2) Customer connector
Illustration 3 g01409254
Location of the connectors and component for the engine prelube system inside the engine mounted control panel (3) Connector for the engine mounted control panel (4) Mating connector for the prelube relay (5) Prelube override switch
Remove the electrical power from the ECM.
Thoroughly inspect the connectors (1), (2), (3) and (4) .
Illustration 4 g01409300
Terminal locations at the P1 ECM connector for the prelubrication system (P1-11) Prelubrication relay (P1-54) Prelube override switch (P1-61) Battery −
Illustration 5 g01409354
Terminal locations at the connector for the engine mounted control panel (Terminal 2) Battery − (Terminal 21) Prelubrication relay (Terminal 37) Prelube override switch
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connectors and the other connections that are associated with the circuit.
Check the allen head screw for each of the ECM connectors for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect " for details.
Check the harness and the wiring for abrasion and for pinch points.Expected Result:All connectors, pins, and sockets are completely coupled and/or inserted. The harness and wiring are free of corrosion, of abrasion, and of pinch points.Results:
OK - The connectors and wiring appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem in the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled.Verify that the repair eliminates the problem.STOPTest Step 2. Check for Active Diagnostic Codes
Connect Cat ET to the service tool connector.
Restore the electrical power to the ECM.
Select diagnostic tests from Cat ET.
Select the "Override Parameters" screen on Cat ET.
Activate the override for the prelubrication system.
Monitor the active diagnostic code screen on Cat ET. Check the prelubrication system for an active diagnostic code.Note: Wait at least 30 seconds in order for the diagnostic code to become active.
Disable the override for the prelubrication system.Expected Result:No diagnostic codes are active.Results:
OK - No diagnostic codes are active, but a problem is suspected in the prelubrication system. Proceed to Test Step 6.
Active -6 Code - A -6 diagnostic code is active at this time. A short is detected in the circuit for the prelubrication relay. Proceed to Test Step 3.
Active -5 Code - A -5 diagnostic code is active at this time. An open is detected in the circuit for the prelubrication relay. Proceed to Test Step 4.Test Step 3. Create an Open Circuit at the Prelubrication Relay
Remove the electrical power from the ECM.
Disconnect the connector for the prelubrication relay.
Restore the electrical power to the ECM.
Select diagnostic tests from Cat ET.
Select the "Override Parameters" screen on Cat ET.
Activate the override for the prelubrication system.
Monitor the active diagnostic code screen on Cat ET. Check the prelubrication system for an active diagnostic code.Note: Wait at least 30 seconds in order for the diagnostic code to become active.
Remove the electrical power from the ECM.Expected Result:A -6 diagnostic code was active for the prelubrication relay. After creating an open at the prelubrication relay, a -5 diagnostic code is now active.Results:
OK - A -6 diagnostic code was active before disconnecting the wire. A -5 diagnostic code became active after disconnecting the wire.Repair: The harness and the ECM are OK. The short circuit is in the prelubrication relay. Perform the following repair:
Temporarily connect a new prelubrication relay.
Recheck the circuit in order to ensure that the original problem is resolved with the installation of the new relay.