362-60211-0 Tohatsu NEEDLE BEARING, 17 - 24 - 20


362-60211-0 NEEDLE BEARING, 17 - 24 - 20 Tohatsu M15D2, M18E2, M9.9D2, MFS15B2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS18B2, MFS20C, MFS20C, MFS9.9B2, MFS9.9B2, MFS9.9C NEEDLE

Buy NEEDLE BEARING, 17 - 24 - 20 362-60211-0 Tohatsu genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$12.50
 

15-05-2022

-: -
Boat Motor Made in Japan Propeller Shaft Needle Bearing Brg 362-60211-0 M 31 803734 For Tohatsu Nissan Parsun Mercury Quicksilver Outboard F 9.9HP 15HP 18HP Engine
Original Brand Made in Japan, highest genuine quality guaranteed assured! || For Tohatsu Nissan Outboard part number: 362-60211-0 (check OEM part number before purchase!!) || For Tohatsu Nissan Outboard Models: M MFS 9.9, 15, 18 horsepower (2 & 4 Strokes) engines. || Propeller Shaft Bearing || Boat Motor for Outboard Engine
Number on catalog scheme: 32
 

Tohatsu entire parts catalog list:

M15D2 2003
M18E2 2003
M9.9D2 2003
MFS15B2 2003,2004,2005,2007,2008
MFS15B2 2006
MFS15C 2008,2009,2011,2012,2013,2014
MFS15C 2010
MFS18B2 2003,2004,2005,2007,2008
MFS18B2 2006
MFS20C 2008,2009,2011,2012,2013,2014
MFS20C 2010
MFS9.9B2 2003,2004
MFS9.9B2 2006
MFS9.9C 2008,2011

Information:


Illustration 1 g00481725
Functional Block Diagram Of The AC Voltage Display In EMCP II+
Illustration 2 g00436699
Relays In Relay Module (1) Jumper block
Table 1
AC Voltage Range Selection    
GSC+ P020 Setpoint    External Potential Trans-
former    AC Trans-
former Box (ATB+) Input Voltage Range    GSC+ Internal Multiplier    Jumper    
700     None     0 - 700     5     Required    
150     None     0 - 150     1     None    
300     2:1     0 - 150     2     None    
500     3.33:1     0 - 150     3.33     None    
600     4:1     0 - 150     4     None    
750     5:1     0 - 150     5     None    
3000     20:1     0 - 150     20     None    
4500     30:1     0 - 150     30     None    
5250     35:1     0 - 150     35     None    
9000     60:1     0 - 150     60     None    
15000     100:1     0 - 150     100     None    
18000     120:1     0 - 150     120     None    
30000     200:1     0 - 150     200     None    Jumper block (1) is used to select the voltage range of the voltmeter of the GSC+. The jumper block (1) is installed for systems with 700 volts full scale AC inputs. Jumper block (1) is NOT installed for systems with 150 volts full scale AC inputs or for any unit with external potential transformers. The relay module is factory equipped with the jumper block (1). Jumper block (1) is easily removed by pulling out. Jumper block (1) is easily installed by aligning and then pushing in. If a jumper block is not available, three separate jumpers can be substituted. Each of the three manufactured jumpers connect a pair of pins. A pair of pins must not touch another pair of pins.The relay module must be removed from the GSC+ in order to gain access to the circuit board and jumper block (1). See Testing And Adjusting, "Relay Module - Replace".The setpoint P020 sets the AC voltage range and the internal multiplier. This is used by the GSC+ for calculating AC voltage. The GSC+ uses the internal multiplier to compensate for the turns ratio of the external potential transformers. The turns ratio of the external potential transformer must match this internal multiplier in order to ensure accurate AC voltage calculation by the GSC+.The jumper block connects a divide-by-five circuit to the AC voltage input of the GSC+. The divide-by-five circuit reduces the AC voltage input to a controllable level for the GSC+ when P020 is 700. When setpoint P020 is 700, a multiplier of five is needed to compensate for the presence of the divide-by-five. This is required even though no external potential transformer is present.Note: When the setpoint P020 is not equal to 700, the jumper block should NOT be installed. This prevents inaccurate calculations of the voltage by the GSC+. The other values (150 through 30, 000) are used with an external potential transformer. The input voltages at the AC Transformer Box + are from 0 ACV to 150 ACV. No further reduction of the input voltage is required.


Parts needle Tohatsu:

350-00042-0
350-60211-0
NEEDLE BEARING, 16 - 24 - 20
350-60211-0 NEEDLE BEARING, 16 - 24 - 20
M15D2, M18E2, M9.9D2, MFS15B2, MFS15B2, MFS18B2, MFS18B2, MFS9.9B2, MFS9.9B2
3G4-00043-0
3BJ-60211-0
 
3BJ-60211-0 NEEDLE BEARING
MFS15C, MFS15C, MFS20C, MFS20C, MFS9.9C
Back to top