346-66323-1 Tohatsu SPRING, REVERSE LOCK LEVER


346-66323-1 SPRING, REVERSE LOCK LEVER Tohatsu M25C3, M30A4, M40C, MFS25A, MFS25B, MFS25B, MFS25B, MFS30A, MFS30B, MFS30B SPRING
346-66323-1 SPRING, REVERSE LOCK LEVER Tohatsu
Rating:
13

Buy SPRING, REVERSE LOCK LEVER 346-66323-1 Tohatsu genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$8.32
 

28-05-2019
13 Hundredths Pounds
Tohatsu: Tohatsu
Tohatsu 346-66323-1 Reverse Lock Lever Spring QTY 1
Genuine OEM Tohatsu Part || OEM Tohatsu 346-66323-1 Reverse Lock Lever Spring QTY 1 || Part Number: 346-66323-1 || Quantity: 1 || May not include original package.
Number on catalog scheme: 21
 

Compatible models:

Tohatsu entire parts catalog list:

M25C3 2003,2005
M30A4 2003
M40C 2004
MFS25A 2003,2004,2005
MFS25B 2005,2006,2007,2008,2009
MFS25B 2010
MFS25B 2011,2012,2013,2014
MFS30A 2003,2004,2005
MFS30B 2005,2006,2007,2008,2009,2011,2012,2013,2014
MFS30B 2010

Information:


Illustration 1 g00836501
Typical schematicTest Step 1. Check for Connector Damage.
Turn the ECS to the OFF/RESET position.
Turn the battery disconnect switch to the OFF position.
Thoroughly inspect the ECM connectors J1/P1 and J2/P2. Inspect all of the other connectors. Refer to the diagnostic functional test Troubleshooting, "Inspecting Electrical Connectors" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque of 6.0 N m (55 lb in).
Check the customer connector (allen head screw) for the proper torque of 2.25 0.25 N m (20 2 lb in).
Check the harness and the wiring for abrasion and for pinch points.Expected Result:All connectors, pins, and sockets are completely coupled and/or inserted. The harness and wiring should be free of corrosion, of abrasion or of pinch points.Results:
OK - The connectors and wiring are okay. Proceed to test step 2.
Not OK - The connectors and/or wiring are not okay.Repair: Repair the connectors or wiring and/or replace the connectors or wiring.STOPTest Step 2. Check the Engine Diagnostics on the Generator Set Control.
Turn the battery disconnect switch to the ON position.
Turn the ECS to the STOP position.
Determine if CID-FMI 545-05 Ether Start Relay open/short to +batt, 545-06 Ether Start Relay short to ground, 546-05 Ether Hold Relay open/short to ground or 546-06 Ether Hold Relay short to +batt is active or logged.Expected Result:No active codes or logged codes are present.Results:
OK - No active codes or logged codes are present. The ether injection system does not inject ether. Proceed to test step 3.
Active Code - Active Diagnostics are displayed. Proceed to test step 4.
Logged Code - Logged Diagnostics are displayed. Check for an intermittent short or for an open in the wiring or in the connectorsRepair: Repair the connectors or wiring and/or replace the connectors or wiring.STOPTest Step 3. Check the Ether Canisters.
Turn the ECS to the OFF/RESET position.
Turn the battery disconnect switch to the OFF position.
Remove the ether canister(s) from the ether solenoid(s). Determine if the canister(s) contains any ether.Expected Result:The ether canister(s) should not be empty.Results:
OK - The ether canister(s) is not empty. Proceed to test step 14.
Not OK - The ether canister(s) is empty.Repair: Replace the empty ether canister with a full ether canister. Retry the system.STOPTest Step 4. Check the Voltage from the Ether Start Relay.
Turn the ECS to the OFF/RESET position.
Turn the battery disconnect switch to the OFF position.
Remove the ether canister(s) from the ether solenoid(s).
Connect the Caterpillar Electronic Technician (ET) to the service tool connector J60/P60.
Connect a voltmeter between terminal 30 of the ether start relay and ground.
Turn the battery disconnect switch to the ON position.
Turn the ECS to the STOP position.
Select the "Diagnostic Tests" on the Cat ET.
Select the "Override Parameters" screen on the Cat ET.
Activate the ether override and observe the voltmeter while ether injection is ON. Disable the ether override.Note: Do not allow the ether to be ON for more than two minutes. Damage to the solenoid may occur.
Measure the voltage at the ether start relay with the voltmeter.
Deactivate the ether override.Expected Result:The voltage at the ether start relay should be 24 3 VDC during the first two seconds of injection. The voltage then decreases to 3 1 VDC for the remainder of the injection duration.Results:
OK - The voltage at the ether start relay is 24 3 VDC during the first two seconds of injection. The voltage then decreases to approximately 3 1 VDC for the remainder of injection duration. Proceed to test step 5.
Not OK - 24 VDC - The voltage at the ether start relay is not 24 3 VDC during the first two seconds of injection. Proceed to test step 6.
Not OK - 3 VDC - The voltage did not decrease to approximately 3 1 VDC for the remainder of the injection duration. Proceed to test step 9.Test Step 5. Check the Voltage at the Ether Solenoids.
Turn the ECS to the OFF/RESET position.
Turn the battery disconnect switch to the OFF position.
Disconnect the ether solenoid connector at the solenoid.
Connect a voltmeter between pin 1 and pin 2 of the ether solenoid connector.
Turn the battery disconnect switch to the ON position.
Turn the ECS to the STOP position.
Select the "Diagnostic Tests" on the Cat ET.
Select the "Override Parameters" screen on the Cat ET.
Activate the ether override and observe the voltmeter while ether injection is ON. Disable the ether override.Note: Do not allow the ether to be ON for more than two minutes. Damage to the solenoid may occur.
Measure the voltage at the ether solenoid connector with the voltmeter.
Deactivate the ether override.
Turn the ECS to the OFF/RESET position.
Turn the battery disconnect switch to the OFF position.
Reconnect all connectors.Expected Result:The voltage at the ether solenoid should be 24 3 VDC during the first two seconds of injection. The voltage then decreases to 3 1 VDC for the remainder of the injection duration.Results:


Parts spring Tohatsu:

941322-0600
 
941322-0600 SPRING WASHER
M115A2, M120A2, M140A2, M15D2, M18E2, M2.5A, M2.5A2, M25C3, M3.5A2, M3.5B2, M30A4, M40D2, M40D2, M40D2, M4C, M50D2, M5B, M5BS, M9.9D2, MD115A, MD115A2
951407-0308
 
951407-0308 SPRING PIN, 3 - 8
M15D2, M18E2, M25C3, M3.5B2, M30A4, M9.9D2, MFS2.5A, MFS2.5B, MFS2.5B, MFS2.5B, MFS2A, MFS2B, MFS3.5A, MFS3.5B, MFS3.5B, MFS3.5B
332-64221-0
SPRING, CLUTCH
332-64221-0 SPRING, CLUTCH
M15D2, M18E2, M25C3, M30A4, M9.9D2, MFS15B2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS18B2, MFS20C, MFS20C, MFS25A, MFS25B, MFS25B, MFS25B, MFS30A, MFS30B, MFS30B, MFS9.9B2, MFS9.9B2, MFS9.9C
941321-0500
 
941321-0500 SPRING WASHER
M40D2, M40D2, M40D2, M50D2, M60C, M70C, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MFS15B2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS18B2, MFS20C, MFS20C, MFS25A, MFS25B, MFS25B, MFS25B, MFS30A, MFS30B, MFS30B, MFS9.
346-66903-0
346-64327-0
 
346-64327-0 SPRING, DRIVE SHAFT
M25C3, M30A4, MFS25A, MFS25B, MFS25B, MFS25B, MFS30A, MFS30B, MFS30B
3R0-10075-0
 
3R0-10075-0 SPRING, TENSIONER
MFS25A, MFS25B, MFS25B, MFS30A, MFS30B, MFS30B
941303-0400
SPRING WASHER
941303-0400 SPRING WASHER
M115A2, M120A2, M140A2, M40C, M40D2, M40D2, M40D2, M50D2, M60C, M70C, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD90C2
Back to top