3R0-76064-0 Tohatsu STAY, FUSE HOLDER


3R0-76064-0 STAY, FUSE HOLDER Tohatsu MFS25A, MFS25B, MFS30A, MFS30B, MFS8A, MFS8A2, MFS8A3, MFS8A3, MFS8A3, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3 STAY
3R0-76064-0 STAY, FUSE HOLDER Tohatsu
Rating:
93

Buy STAY, FUSE HOLDER 3R0-76064-0 Tohatsu genuine, new aftermarket parts with delivery
Number on catalog scheme: 9
 

Tohatsu entire parts catalog list:

MFS25A 2003,2004,2005
MFS25B 2005,2006,2007,2008,2009
MFS30A 2003,2004,2005
MFS30B 2005,2006,2007,2008,2009,2011,2012,2013,2014
MFS8A 2003,2004
MFS8A2 2004,2005
MFS8A3 2006
MFS8A3 2007,2008,2009
MFS8A3 2010
MFS8A3 2011,2012,2013,2014
MFS9.8A 2003,2004
MFS9.8A2 2004,2005
MFS9.8A3 2006
MFS9.8A3 2007,2008,2009
MFS9.8A3 2010
MFS9.8A3 2011,2012,2013,2014

Information:

Probable Causes
Diagnostic codes
ECM parameters
Throttle signal from the CAN data link
Air intake and exhaust system
Fuel supply
Low compression (cylinder pressure)
Electronic unit injectors
Individual malfunctioning cylindersRecommended Actions
Diagnostic Codes
Use one of the following methods to check for active diagnostic codes:
The electronic service tool
The display on the control panelElectronic Service Tool
Connect the electronic service tool to the diagnostic connector.
Check for active diagnostic codes on the electronic service tool.
Investigate any active codes before continuing with this procedure. Refer to Troubleshooting, "Troubleshooting with a Diagnostic Code".Display on the Control PanelNote: The following procedure is only applicable if the application is equipped with a display on the control panel.
Check the display on the control panel for active diagnostic codes.
Troubleshoot any active codes before continuing with this procedure. Refer to Troubleshooting, "Troubleshooting with a Diagnostic Code".ECM Parameters
Ensure that the fault is not an incorrect or missing programmed parameter.
Use the electronic service tool to verify the correct engine rating for the engine.
Use the electronic service tool to verify the maximum engine speed limit.
Use the electronic service tool to verify the following parameters at maximum speed: the boost pressure, the smoke limit, the torque limit and the amount of fuel that is delivered.
Use the electronic service tool to reset the parameters to the OEM specifications.
Ensure that the repairs have eliminated the fault.
If the repairs have not eliminated the fault, proceed to "Throttle Signal from the CAN Data Link".Throttle Signal from the CAN Data Link
Use the electronic service tool and observe the signal from the CAN data link. Make sure that the throttle reaches the 100% raw position and the calibrated position.
If the signal is erratic, refer to Troubleshooting, "CAN Data Link Circuit - Test".
If the fault has not been eliminated, proceed to "Air Intake and Exhaust System".Air Intake and Exhaust System
Check the air filter restriction indicator, if equipped.
Ensure that the air filter is clean and serviceable.
Check the air intake and the exhaust system for the following defects:
Blockages
Restrictions
Damage to the air intake and exhaust lines and hoses
Make all necessary repairs to the engine.
Ensure that the repairs have eliminated the fault.
If the fault has not been eliminated, proceed to "Fuel Supply".Fuel Supply
Contact with high pressure fuel may cause fluid penetration and burn hazards. High pressure fuel spray may cause a fire hazard. Failure to follow these inspection, maintenance and service instructions may cause personal injury or death.
Contact with high-pressure fuel may cause personal injury or death. Wait 10 minutes after the engine has stopped to allow fuel pressure to purge before any service or repair is performed on the engine fuel lines.
Check for leaks from the high-pressure fuel lines. If the high-pressure fuel lines have a leak, the high-pressure fuel lines must be replaced. Refer to Disassembly and Assembly, "Fuel injection lines - Remove" and Disassembly and Assembly, "Fuel injection lines - Install".
If equipped, ensure that the fuel supply valve is in the full OPEN position.
If the temperature is below 0 °C (32 °F), check for solidified fuel (wax).
Visually inspect the fuel supply lines for restrictions.
Check that the low-pressure fuel lines are tight and secured properly.
Replace the in-line fuel strainer that is installed upstream of the Electric Fuel Lift Pump (EFLP).
Remove the fuel filters. Inspect the fuel filters for contamination. Install new fuel filters. Refer to the Operation and Maintenance Manual, "Fuel System Filter- Replace and Fuel System Primary Filter (Water Separator) Element - Replace". Determine the cause of the contamination.
Check the diesel fuel for contamination. Refer to Systems Operation, Testing, and Adjusting, "Fuel Quality - Test".
Check for air in the low-pressure fuel system. Refer to Systems Operation, Testing, and Adjusting, "Air in Fuel - Test".
Turn the keyswitch to the OFF position and then disconnect the electrical connector from the EFLP.
With the keyswitch in the ON position, measure the voltage at the harness connector for the EFLP. The voltage must be between 20 VDC and 28 VDC. If the voltage is below 20 VDC, investigate the cause. Refer to Troubleshooting, "Fuel Pump Relay Circuit - Test".
Turn the keyswitch to the OFF position and then reconnect the electrical connector to the EFLP.
If a repair has been performed to rectify a low supply voltage to the EFLP, attempt to start the engine. If the engine does not start, continue with this procedure.Note: Before performing the following fuel system tests, the engine must be stopped for a minimum of 30 minutes.Note: When performing the following fuel system tests, the Electric Fuel Lift Pump (EFLP) will only operate for 2 minutes unless the engine is running. If necessary, cycle the keyswitch in order to reactivate the pump.
Use the following procedure to check the flow from the Transfer Pump Inlet Regulator (TPIR):
Illustration 1 g02522678
Locations in the low-pressure fuel system (1) Fuel return line to the secondary fuel filter (2) Secondary fuel filter base (3) Transfer Pump Inlet Regulator (TPIR) (4) TPIR return port
Disconnect the TPIR return line from the drain port (4) on the TPIR (3) . Install a suitable blanking cap on the open port in the TPIR return line
Connect a temporary drain line to the drain port on the TPIR.
Place the end of the temporary drain line into a suitable calibrated container.
With the keyswitch in the ON position but the engine not running, use a suitable multimeter to measure the input voltage to the EFLP. Record the reading.
With the keyswitch in the ON position but the engine not running, measure the fuel flow from the temporary drain line. Refer to Illustration 2 for the minimum acceptable flow rate.
Illustration 2 g02522799
Minimum TPIR flo


Parts stay Tohatsu:

3V1-06284-0
 
3V1-06284-0 STAY TERMINAL HOLDER
MFS8A, MFS8A2, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3
3AC-63737-0
 
3AC-63737-0 STAY
MFS25B, MFS25B, MFS25B, MFS30B, MFS30B
3V1-06284-1
 
3V1-06284-1 STAY, CABLE TERMINAL HOLDER
MFS8A3, MFS8A3, MFS8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3
3Z0-76174-0
 
3Z0-76174-0 STAY
MFS8A3, MFS8A3, MFS8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3
Back to top