3V1-67501-0 Tohatsu SEAL RUBBER, TOP COWL


3V1-67501-0 SEAL RUBBER, TOP COWL Tohatsu MFS8A, MFS8A2, MFS8A3, MFS8A3, MFS8A3, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3 SEAL
3V1-67501-0 SEAL RUBBER, TOP COWL Tohatsu
Rating:
105

Buy SEAL RUBBER, TOP COWL 3V1-67501-0 Tohatsu genuine, new aftermarket parts with delivery
Number on catalog scheme: 23-1
 

Compatible models:

Tohatsu entire parts catalog list:

MFS8A 2003,2004
MFS8A2 2004,2005
MFS8A3 2006
MFS8A3 2007,2008,2009
MFS8A3 2010
MFS8A3 2011,2012,2013,2014
MFS9.8A 2003,2004
MFS9.8A2 2004,2005
MFS9.8A3 2006
MFS9.8A3 2007,2008,2009
MFS9.8A3 2010
MFS9.8A3 2011,2012,2013,2014

Information:


Illustration 1 g00584152
Wye Configuration Of External Potential Transformers (PT) On 4-Wire Wye Generator
This configuration allows the accurate measurement of all power parameters by the GSC+ including when the loads are unbalanced and neutral current is present. All power parameters are shown on the display of the GSC+.
Illustration 2 g00584153
Open Delta Configuration Of External Potential Transformers (PT) On The 3-Wire Delta Generator
This configuration allows the accurate measurement of power parameters by the GSC+ including when the loads are unbalanced and circulating current is present. The real power phase A, B and C can not be determined. The power factor phase A, B and C can not be determined. The phases are not shown on the GSC+ display.
Illustration 3 g00584154
Open Delta Configuration Of External Potential Transformers (PT) On The 4-Wire Wye Generator
This configuration results in less accurate measurement of all power parameters by the GSC+ when the loads are unbalanced and neutral current is present. Real power phase A, B, C and power factor phase A, B, C can not be determined and are not shown on the GSC+ display.
Note: The wye configuration of external potential transformers (PT's) is preferred for 4-wire wye generators because of the greater accuracy when loads are unbalanced. With the open delta configuration, some power parameters can not be determined. These parameters are real power phase A, B, C and power factor phase A, B, C. For maximum accuracy, the open delta configuration of external PT's should be used only for 3-wire delta generators.On 4-wire wye generators, three separate potential transformers (PT's) are required for accurate power metering unless the loads are completely and continually balanced. Even if the loads are balanced, some power parameters can not be determined. These parameters are not shown on the GSC+ display: real power phase A, B, C and power factor phase A, B, C. The ATB+ contains three potential transformers in order to accommodate 4-wire wye generators. The full capabilities of the ATB+ are not utilized when an open delta PT configuration is used for 4-wire wye generators.On 3-wire delta generators, two potential transformers allow maximum accuracy for all load conditions. However, again real power phase A, B, C and power factor phase A, B, C can not be determined and are not shown on the GSC+ display.The GSC+ must be programmed when connecting external PT's to the ATB+.Procedure For Programming When PT's Are Used
Program setpoint P032 in order to match the configuration of the external PT's. Setpoint P032 must always match the configuration of the external PT's regardless of whether the generator is a wye or delta. This is necessary because the ATB+ is connected only to the external PT's and cannot sense the generator connections.
For external PT's that are connected in a wye configuration, program setpoint P032 to 0 (wye). Setpoint P032 is also programmed to 0 when no PT's are present on wye generators.
For external PT's that are connected in a delta configuration, program setpoint P032 to 1 (delta). Setpoint P032 is also programmed to 1 when no PT's are present on delta generators.Note: When setpoint P032 is programmed to 1 (delta), real power phase A, B, C and power factor phase A, B, C can not be determined and are not shown on the GSC+ display.
Program setpoint P020 to match the turns ratio of the external PT's. See the AC Voltage Range Selection chart in Testing And Adjusting, "AC Voltage Range - Adjust". Setpoint P020 should match the turns ratio of the external PT's independent of whether setpoint P032 is programmed for wye or delta.


Parts seal Tohatsu:

338-67147-0
SEAL RING, HOOK LEVER
338-67147-0 SEAL RING, HOOK LEVER
M115A2, M15D2, M18E2, M25C3, M30A4, M40C, M40D2, M40D2, M40D2, M4C, M50D2, M5B, M5BS, M60C, M70C, M8B, M9.8B, M9.9D2, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD75C2, MD90B, MD90C2, MFS1
3V1-65206-0
 
3V1-65206-0 SEAL UPPER, WATER PIPE
MFS8A, MFS8A2, MFS8A3, MFS8A3, MFS8A3, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3
3R3-07204-0
 
3R3-07204-0 SEAL, "IN" VALVE STEM
MFS15B2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS18B2, MFS2.5A, MFS2.5B, MFS2.5B, MFS2.5B, MFS20C, MFS20C, MFS25A, MFS25B, MFS25B, MFS25B, MFS2A, MFS2B, MFS3.5A, MFS3.5B, MFS3.5B, MFS3.5B, MFS30A, MFS30B, MFS30B, MFS8A, MFS8A2, MFS8A3, MFS8A3, MFS8A3, M
3R3-07206-0
 
3R3-07206-0 SEAL, "EX" VALVE STEM
MFS15B2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS18B2, MFS2.5A, MFS2.5B, MFS2.5B, MFS2.5B, MFS20C, MFS20C, MFS25A, MFS25B, MFS25B, MFS25B, MFS2A, MFS2B, MFS3.5A, MFS3.5B, MFS3.5B, MFS3.5B, MFS30A, MFS30B, MFS30B, MFS8A, MFS8A2, MFS8A3, MFS8A3, MFS8A3, M
3V1-67503-0
3V1-66187-0
 
3V1-66187-0 SEAL RING, 23 - 29 - 3.7
MFS8A, MFS8A2, MFS8A3, MFS8A3, MFS8A3, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3
3F3-84908-0
SEAL RING, DRAG LINK
3F3-84908-0 SEAL RING, DRAG LINK
M115A2, M120A2, M140A2, M15D2, M18E2, M25C3, M30A4, M40C, M40D2, M40D2, M40D2, M50D2, M60C, M70C, M9.9D2, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD9
3R0-77173-0
 
3R0-77173-0 SEAL WASHER
M40D2, M40D2, M40D2, M50D2, MD40B, MD40B, MD40B2, MD40B2, MD50B, MD50B, MD50B, MD50B2, MD50B2, MFS25A, MFS25B, MFS30A, MFS30B, MFS8A3, MFS8A3, MFS8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3
Back to top