3A3-84429-0 Tohatsu CABLE COVER


3A3-84429-0 CABLE COVER Tohatsu MD115A2, MD40B2, MD40B2, MD50B2, MD50B2, MD70B, MD75C2, MD90B, MD90C2, MFS15C, MFS20C, MFS25B, MFS25B, MFS30B, MFS4B, MFS5B, MFS6B, MFS8A3, MFS8A3, MFS8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3 CABLE
3A3-84429-0 CABLE COVER Tohatsu
Rating:
98

Buy CABLE COVER 3A3-84429-0 Tohatsu genuine, new aftermarket parts with delivery
Number on catalog scheme: 31
 

Tohatsu entire parts catalog list:

MD115A2 2010,2012,2013,2014
MD40B2 2010
MD40B2 2011,2012,2013,2014
MD50B2 2010
MD50B2 2011,2012,2013,2014
MD70B 2010
MD75C2 2010,2011,2012,2013,2014
MD90B 2010
MD90C2 2010,2011,2012,2013,2014
MFS15C 2010
MFS20C 2010
MFS25B 2010
MFS25B 2011,2012,2013,2014
MFS30B 2010
MFS4B 2010
MFS5B 2010
MFS6B 2010
MFS8A3 2007,2008,2009
MFS8A3 2010
MFS8A3 2011,2012,2013,2014
MFS9.8A3 2007,2008,2009
MFS9.8A3 2010
MFS9.8A3 2011,2012,2013,2014

Information:


Table 1
Event Code
Description Conditions which Activate the Code System Response
E243 (1) High Left Turbo Turbine Outlet Temperature The temperature at the outlet for the left turbocharger turbine has exceeded the trip point and the delay time has expired. The alarm output is activated. The code is logged.
E243 (3) High Left Turbo Turbine Outlet Temperature The shutdown output is activated. The code is logged. The engine is shut down.
E244 (1) High Right Turbo Turbine Outlet Temperature The temperature at the outlet for the right turbocharger turbine has exceeded the trip point and the delay time has expired. The alarm output is activated. The code is logged.
E244 (3) High Right Turbo Turbine Outlet Temperature The shutdown output is activated. The code is logged. The engine is shut down.
E245 (1) High Right Turbo Turbine Inlet Temperature The temperature at the inlet for the right turbocharger turbine has exceeded the trip point and the delay time has expired. The alarm output is activated. The code is logged.
E245 (3) High Right Turbo Turbine Inlet Temperature The fuel is shut off. The shutdown output is activated. The code is logged. The engine is shut down.
E246 (1) High Left Turbo Turbine Inlet Temperature The temperature at the inlet for the left turbocharger turbine has exceeded the trip point and the delay time has expired. The alarm output is activated. The code is logged.
E246 (3) High Left Turbo Turbine Inlet Temperature The fuel is shut off. The shutdown output is activated. The code is logged. The engine is shut down. Note: Refer to Troubleshooting, "Engine Monitoring System" for information on trip points and delay times.Probable Causes
High inlet air temperature
Incorrect base timing
Exhaust restriction
A buildup of deposits in the cylinder or internal oil leaksRecommended Repairs
Check for Event Codes for High Inlet Air Temperature
Use the Caterpillar Electronic Technician (ET) to check for the following event codes:
E027 (1) High Inlet Air Temperature Warning
E368 (1) High Inlet Air Temperature Warning
E025 (2) High Inlet Air Temperature Derate
E368 (2) High Inlet Air Temperature Derate
E026 (3) High Inlet Air Temperature Shutdown
E368 (3) High Inlet Air Temperature ShutdownIf either code is active or logged, refer to Troubleshooting, "Inlet Air Temperature Is High".Check the Base Timing
Verify that the base timing is correct. Refer to Systems Operation/Testing and Adjusting, "Ignition Timing - Adjust".Measure the Exhaust Restriction
Measure the exhaust restriction during engine operation with a load. For data that is specific to the engine, refer to the Technical Marketing Information.Investigate the cause of the exhaust restriction. Perform adjustments and/or make repairs, as needed.Check for Deposits in the Cylinder and Check for Internal Oil Leaks
Use a borescope to inspect the cylinders. Look for the following conditions:
Deposits on the valve seats
Deposits on the valve faces
Deposits on the cylinder walls that are above the upper limit of the piston stroke
Signs of internal oil leaksOther signs of internal oil leaks include high oil consumption and blue smoke.Note: Excessive deposits contribute to guttering of the valves.If excessive deposits and/or signs of internal oil leaks are found, investigate the cause of the condition. Make repairs, as needed.


Parts cable Tohatsu:

3V1-83820-0
 
3V1-83820-0 CABLE CLIP
MFS8A, MFS8A2, MFS8A3, MFS8A3, MFS8A3, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3
3B7-83715-0
 
3B7-83715-0 CABLE JOINT
M120A2, M140A2, M40D2, M40D2, M40D2, M50D2, M60C, M70C, MD40A, MD40B, MD50A, MD50B, MD50B, MD70B, MD70B, MD90B, MD90B, MFS15B2, MFS18B2, MFS25A, MFS30A, MFS8A, MFS8A2, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3, MFS9.9B2
3R0-83715-0
 
3R0-83715-0 CABLE JOINT
MFS25A, MFS25B, MFS25B, MFS25B, MFS30A, MFS30B, MFS30B, MFS8A, MFS8A2, MFS8A3, MFS8A3, MFS8A3, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3
353-83728-0
 
353-83728-0 CABLE PIN
M120A2, M140A2, M15D2, M18E2, M25C3, M30A4, M40C, M60C, M70C, M9.9D2, MD70B, MD70B, MD90B, MD90B
3B7-83720-0
 
3B7-83720-0 CABLE CLIP
M115A2, M120A2, M140A2, MD115A, MD115A2
3B7-83715-1
CABLE JOINT
3B7-83715-1 CABLE JOINT
M115A2, MD115A, MD115A2, MD40B, MD40B2, MD40B2, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90C2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS20C, MFS20C, MFS25B, MFS25B, MFS25B, MFS30B, MFS30B, MFS8A3, MFS8A3, MFS8A3, MFS8A3, MFS9.8A3, MFS
3H6-63505-0
 
3H6-63505-0 CABLE HOLDER
MFS2.5A, MFS2.5B, MFS2.5B, MFS2.5B, MFS2A, MFS2B, MFS3.5A, MFS3.5B, MFS3.5B, MFS3.5B, MFS4B, MFS4B, MFS5B, MFS5B, MFS6B, MFS6B
3H6-76037-0
 
3H6-76037-0 CABLE TERMINAL PLUG
MFS4B, MFS4C, MFS5B, MFS5C, MFS6B, MFS6C
Back to top