3037300 Volvo.Penta Anchorage


3037300 Anchorage Volvo.Penta DH10A; DH10A 285; DH10A 360 Anchorage
3037300 Anchorage Volvo Penta
Rating:
23

Buy Anchorage 3037300 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$74.45
 

06-10-2021
0.000625[0.00] Pounds
-: -
3037300, Conn Feed-Through Modular Terminal Block F 2 POS T DIN Rail 17.5A (25 Items)
 

06-10-2021

-: -
Hach 3037300 610 nm Color Filter Module for 2100AN
Description : Color Filter Module, 610 nm || Supplier No. : 3037300 || Unit : Each
Number on catalog scheme: 18
 

Compatible models:

Volvo Penta entire parts catalog list:

DH10A; DH10A 285; DH10A 360; DH10A Rail; THD102KD; THD102KB

Information:


Table 1
Cross-Reference from CDL Code to Functional Test or Procedure
CDL Code and Description Functional Test or Procedure
247-9
SAE J1939 Data Link : Abnormal Update Rate The SCR system ECM has detected a loss of communication on the global CAN data link.
Troubleshooting, "Data Link - Test"
2348-9
SAE J1939 Data Link #2 : Abnormal Update Rate The SCR system ECM has detected a loss of communication on the local CAN data link.
Troubleshooting, "Data Link - Test"
3002-6
Engine Exhaust NOx Level Sensor : Current Above Normal Troubleshooting, "Data Link - Test"
3002-9
Engine Exhaust NOx Level Sensor : Abnormal Update Rate Troubleshooting, "Data Link - Test"
3002-12
Engine Exhaust NOx Level Sensor : Failure During a self-test, the NOx sensor has detected an internal fault.
Replace the sensor.
3134-3
Aftertreatment #1 SCR Catalyst Reagent Tank #1 Temperature Sensor : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Passive) - Test"
3134-4
Aftertreatment #1 SCR Catalyst Reagent Tank #1 Temperature Sensor : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Passive) - Test"
3609-6
Aftertreatment #1 Outlet #1 NOx Level Sensor : Current Above Normal Troubleshooting, "Data Link - Test"
3609-9
Aftertreatment #1 Outlet #1 NOx Level Sensor : Abnormal Update Rate Troubleshooting, "Data Link - Test"
3609-12
Aftertreatment #1 Outlet #1 NOx Level Sensor : Failure During a self-test, the NOx sensor has detected an internal fault.
Replace the sensor.
3610-6
Aftertreatment #1 Outlet #2 NOx Level Sensor : Current Above Normal Troubleshooting, "Data Link - Test"
3610-9
Aftertreatment #1 Outlet #2 NOx Level Sensor : Abnormal Update Rate Troubleshooting, "Data Link - Test"
3610-12
Aftertreatment #1 Outlet #2 NOx Level Sensor : Failure During a self-test, the NOx sensor has detected an internal fault.
Replace the sensor.
262-3
5 Volt Sensor DC Power Supply : Voltage Above Normal Troubleshooting, "Sensor Supply - Test"
262-4
5 Volt Sensor DC Power Supply : Voltage Below Normal Troubleshooting, "Sensor Supply - Test"
2131-3
5 Volt Sensor DC Power Supply #2 : Voltage Above Normal Troubleshooting, "Sensor Supply - Test"
2131-4
5 Volt Sensor DC Power Supply #2 : Voltage Below Normal Troubleshooting, "Sensor Supply - Test"
3090-3
Aftertreatment #1 SCR Dosing Reagent Pressure Sensor : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
3090-4
Aftertreatment #1 SCR Dosing Reagent Pressure Sensor : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
3092-3
Aftertreatment #1 SCR Dosing Air Assist Pressure Sensor : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
3092-4
Aftertreatment #1 SCR Dosing Air Assist Pressure Sensor : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
3094-5
Aftertreatment #1 SCR Dosing Air Assist Signal : Current Below Normal Troubleshooting, "Solenoid Valve - Test"
3094-6
Aftertreatment #1 SCR Dosing Air Assist Signal : Current Above Normal Troubleshooting, "Solenoid Valve - Test"
3107-3
Aftertreatment #1 SCR Catalyst Outlet Gas Temperature Sensor : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
3107-4
Aftertreatment #1 SCR Catalyst Outlet Gas Temperature Sensor : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
3110-5
Aftertreatment #1 SCR Catalyst Reagent Line Heater #1 : Current Below Normal
Note: The code is for the supply side relay. Troubleshooting, "Relay - Test"
3110-6
Aftertreatment #1 SCR Catalyst Reagent Line Heater #1 : Current Above Normal
Note: The code is for the supply side relay. Troubleshooting, "Relay - Test"
3111-5
Aftertreatment #1 SCR Catalyst Reagent Line Heater #2 : Current Below Normal
Note: The code is for the return side relay. Troubleshooting, "Relay - Test"
3111-6
Aftertreatment #1 SCR Catalyst Reagent Line Heater #2 : Current Above Normal
Note: The code is for the return side relay. Troubleshooting, "Relay - Test"
3120-5
Aftertreatment #1 SCR Catalyst Reagent Return Signal : Current Below Normal Troubleshooting, "Solenoid Valve - Test"
3120-6
Aftertreatment #1 SCR Catalyst Reagent Return Signal : Current Above Normal Troubleshooting, "Solenoid Valve - Test" Diagnostic Codes
Diagnostic codes alert the operator that a problem in the electronic system has been detected. Diagnostic codes are also used by the service technician to identify the nature of the problem. Caterpillar Electronic Technician (ET) is a software program that runs on a personal computer. The software can be used by the service technician in order to view the diagnostic code information for an ECM. The diagnostic code will be displayed as a two-element code. The following terms describe the elements of the code :Suspect Parameter Number (SPN) - The SPN is a code which is assigned to each component in order to identify data.Failure Mode Identifier (FMI) - The FMI indicates the type of failure.Refer to Table 1 for a complete list of the diagnostic codes and the appropriate troubleshooting procedure.Note: Do not confuse diagnostic codes with event codes. Event codes alert the operator that an abnormal operating condition such as low oil pressure or high coolant temperature has been detected. If an event code is active, refer to Troubleshooting, "Event Codes".Illustration 1 is an example of the operating range of a sensor.
Illustration 1 g01365757
Example of the typical operating range of a sensor
(1) This area represents the normal operating range of the engine parameter.
(2) In these areas, the engine is operating in an unsafe operating range of the monitored parameter. An event code will be generated for the monitored parameter. The sensor circuit does not have an electronic problem. Refer to Troubleshooting, "Event Codes" for additional information on event codes.
(3) In these areas, the signal from the sensor is outside of the operating range of the sensor. The sensor circuit has an electronic problem. A diagnostic code will be generated for the sensor circuit.Active Diagnostic Codes
An active diagnostic code represents a problem with the electronic control system. Correct the problem as soon as possible.When the ECM generates an active diagnostic code. The "Active Alarm" indicator ("Control Alarm Status" on Cat ET) is activated in order to alert the operator. If the condition that generated the code is momentary, the message disappears from the list of active diagnostic codes. The diagnostic code becomes logged.Logged Diagnostic Codes
When the ECM generates a diagnostic code, the ECM logs the code in permanent memory. The ECM has an internal diagnostic clock. Each ECM will record the following information when a code is generated :
The hour of the first occurrence of the code
The hour of the last occurrence of the code
The number of occurrences of the codeThis information is a valuable indicator for troubleshooting intermittent problems.A code is cleared from


Parts anchorage Volvo Penta:

1136551
 
1136551 Anchorage
D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D5A-T; D5A-TA; D5A-B TA, DH10A; DH10A 285; DH10A 360, TAD1230P; TD121GP-87; TWD1210P, TAMD71A; TAMD72A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B, TD121
466919
 
466919 Anchorage
DH10A; DH10A 285; DH10A 360, TD60A; TD60B; TD60B PP, TD60D; TD60D-83; TD60DPP-83
9517665
 
9517665 Anchorage
DH10A; DH10A 285; DH10A 360
9518054
 
9518054 Anchorage
DH10A; DH10A 285; DH10A 360
Back to top