3854130 Volvo.Penta Anode


3854130 Anode Volvo.Penta AD31L-A; AD31P-A; AD41L-A, DP-SM; DP-SM 1.68; DP-SM 1.78, KAD32P; TAMD42WJ-A; KAD43P-A, MD22L; MD22P; MD22L-B, SX-C; SX-C1; SX-C2, SX-M1; SX-M1 1.43; SX-M1 1.51, SX-M; SX-MTD; SX-MTD3, SX-S; SX-SLT; SX-ST, TSKs; SX-M; 1998-2005, TSKs; SX-M; 2006-2008 Anode
3854130 Anode Volvo Penta
Rating:
43

Buy Anode 3854130 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$17.45
 

19-09-2023

-: -
US Marine Products LLC Zinc Anode for Volvo Penta SX/DP-SM Outdrive Transom Shield Replaces 3854130
Zinc Anode For Volvo Penta SX/DP-SM Outdrive Transom Shield Replaces 3854130
$80.99
 

18-11-2022

-: -
Zinc Anode 3854130 3855411 kit for Volvo Outboard SX and DP-SM
Manufacturer Part Number: 3854130 3855411 || Applicable model: For Volvo Outboard SX and DP-SM || Advantage: Easy to install || Material: Zinc alloy || Warranty: Half a year
$75.99
 

18-11-2022

-: -
Aluminium Anode 3854130 3855411 kit for Volvo Outboard SX and DP-SM
Manufacturer Part Number: 3854130 3855411 || Applicable model: For Volvo Outboard SX and DP-SM || Advantage: Easy to install || Material: Aluminium alloy || Warranty: Half a year
Number on catalog scheme: 12
 

Volvo Penta entire parts catalog list:

AD31L-A; AD31P-A; AD41L-A; AD41P-A; D41L-A; TAMD31L-A; TAMD31M-A; TAMD31P-A; TAMD31S-A; TAMD41H-A; TAMD41H-B; TAMD41P-A; TAMD41L-A; TAMD41M-A
DP-SM; DP-SM 1.68; DP-SM 1.78; DP-SM 1.95; DP-SM 2.32; DP-SMTD; DP-SMTD1; DP-SMTD 1.95; DP-SMTD1 1.95; DP-SMTD3; DP-SMTD3 2.11
KAD32P; TAMD42WJ-A; KAD43P-A; KAMD43P; KAMD43P-A; KAMD43P-B; KAD44P; KAD44P-B; KAD44P-C; KAMD44P-A; KAMD44P-C; KAD300-A; KAMD300-A; HS1A; HS1E
MD22L; MD22P; MD22L-B; MD22P-B; TMD22-B; TMD22P-C; TAMD22P-B; HS25A; HS25A-B; 120S-E; MS2A-E; MS2L-E; MS2B-L; TMD22B
SX-C; SX-C1; SX-C2; SX-CT; SX-CT1; SX-R; SX-RT1; SX-RT2; DP-S; DP-S1; SX-C1AC; TSK SX-C1; TSK SX-C1AC; TSK DP-S; TSK SX-C; SX-CT2; TSK SX-C2AC; T
SX-M1; SX-M1 1.43; SX-M1 1.51; SX-M1 1.60; SX-M1 1.66; SX-M1 1.79; SX-M1 1.89; SX-M1 1.97; SX-M1 2.18
SX-M; SX-MTD; SX-MTD3; SX-M 1.43; SX-M 1.51; SX-M 1.60; SX-M 1.66; SX-M 1.79; SX-M 1.89; SX-M 1.97; SX-M 2.18; SX-MTD 1.66; SX-MTD 1.79; SX-M
SX-S; SX-SLT; SX-ST; TSK SX-S; TSK SX-SLT
TSKs; SX-M; 1998-2005; TSK SX-M; TSK SX-MDA; TSK SX-MDB; TSK SX-MDC; TSK SX-MLT; TSK SX-MHP; TSK SX-MBAC; TSK SX-MACLT; SX-MAC; TSK SX-MAC
TSKs; SX-M; 2006-2008; TSK SX-M; TSK SX-MACLT; TSK SX-MBAC; TSK SX-MHP

Information:


Table 1
Typical Voltage Of Electrical System During Cranking At Various Ambient Temperatures
Temperature 12 V System 24 V System
−23 to −7°C (−10 to 20°F) 6 to 8 V 12 to 16 V
−7 to 10°C (20 to 50°F) 7 to 9 V 14 to 18 V
10 to 27°C (50 to 80°F) 8 to 10 V 16 to 24 V Table 2 shows the maximum acceptable loss of voltage in the battery circuit. The battery circuit supplies high current to the starting motor. The values in the table are for engines which have service of 2000 hours or more.
Table 2
Maximum Acceptable Voltage Drop In The Starting Motor Circuit During Cranking
Circuit 12 V System 24 V System
Battery post "-" to the starting motor terminal "-" 0.7 V 1.4 V
Drop across the disconnect switch 0.5 V 1.0 V
Battery post "+" to the terminal of the starting motor solenoid "+" 0.5 V 1.0 V
Solenoid terminal "Bat" to the solenoid terminal "Mtr" 0.4 V 0.8 V Voltage drops that are greater than the amounts in table 2 are caused most often by the following conditions:
Loose connections
Corroded connections
Faulty switch contactsDiagnosis Procedure
The procedures for diagnosing the starting motor are intended to help the technician determine if a starting motor needs to be replaced or repaired. The procedures are not intended to cover all possible problems and conditions. The procedures serve only as a guide.
If equipped with electric start, do not crank the engine for more than 30 seconds. Allow the starter to cool for two minutes before cranking again.Never turn the disconnect switch off while the engine is running. Serious damage to the electrical system can result.
If the starting motor does not crank or cranks slow, perform the following procedure:
Measure the voltage of the battery. Measure the voltage across the battery posts with the multimeter when you are cranking the engine or attempting to crank the engine. Do not measure the voltage across the cable post clamps.
If the voltage is equal to or greater than the voltage in table 1, then go to step 2.
The battery voltage is less than the voltage in Table 1. A low charge in a battery can be caused by several conditions.
Deterioration of the battery
A shorted starting motor
A faulty alternator
Loose drive belts
Current leakage in another part of the electrical system
Measure the current that is sent to the starting motor solenoid from the positive post of the battery. Note: If the following conditions exist, do not perform the test in step 2 because the starting motor has a problem.
The voltage at the battery post is within 2 V of the lowest value in the applicable temperature range of table 1.
The large starting motor cables get hot.Use a suitable ammeter in order to measure the current. Place the jaws of the ammeter around the cable that is connected to the "bat" terminal. Refer to Specifications, "Starter Motor" for the maximum current that is allowed for no load conditions.The current and the voltages that are specified in Specifications are measured at a temperature of 27°C (80°F). When the temperature is below 27°C (80°F), the voltage will be lower through the starting motor. When the temperature is below 27°C (80°F), the current through the starting motor will be higher. If the current is too great, a problem exists in the starting motor. Repair the problem or replace the starting motor.If the current is within the specification, proceed to step 3.
Measure the voltage of the starting motor.
Use the multimeter in order to measure the voltage of the starting motor, when you are cranking or attempting to crank the engine.
If the voltage is equal to or greater than the voltage that is given in table 1, then the battery and the starting motor cable that goes to the starting motor are within specifications. Go to step 5.
The starting motor voltage is less than the voltage specified in table 1. The voltage drop between the battery and the starting motor is too great. Go to step 4.
Measure the voltage.
Measure the voltage drops in the cranking circuits with the multimeter. Compare the results with the voltage drops which are allowed in table 2.
Voltage drops are equal to the voltage drops that are given in table 2 or the voltage drops are less than the voltage drops that are given in Table 2. Go to step 5 in order to check the engine.
The voltage drops are greater than the voltage drops that are given in table 2. The faulty component should be repaired or replaced.
Rotate the crankshaft by hand in order to ensure that the crankshaft is not stuck. Check the oil viscosity and any external loads that could affect the engine rotation.
If the crankshaft is stuck or difficult to turn, repair the engine.
If the engine is not difficult to turn, go to step 6.
Attempt to crank the starting motor.
The starting motor cranks slowly. Remove the starting motor for repair or replacement.
The starting motor does not crank. Check for the blocked engagement of the pinion gear and flywheel ring gear.Note: Blocked engagement and open solenoid contacts will give the same electrical symptoms.


Parts anode Volvo Penta:

853498
Anode kit, insulator
853498 Anode kit, insulator
1372, 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ125B, AQ131A; AQ131B; AQ131C, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A;
876138
Anode kit
876138 Anode kit
430; 430A; 430B, 500; 500A; 501A, 740A; BB740A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ205A; AQ205LB, AQ211A; DP-A; SP-A, AQ231A; AQ231B; AQ231LB, AQ271A; AQ271B; AQ271C, DP-C1; DP-D1; DP-S, DP-E; SP-E; TSK DP-E, D
853387
Anode
853387 Anode
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D2-55; D2-55B; D2-55C, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P-A; HS1A, MD2010-C; MD2010-D; MD2020-C, MD2010A; MD2020A; MD2030A, MD2010B; MD2020B; MD2
3586461
Anode, aluminum
3586461 Anode, aluminum
DP-SM; DP-SM 1.68; DP-SM 1.78, SX-M1; SX-M1 1.43; SX-M1 1.51, SX-M; SX-MTD; SX-MTD3, TSKs; SX-M; 1998-2005, TSKs; SX-M; 2006-2008
3863193
Anode, aluminum
3863193 Anode, aluminum
DP-SM; DP-SM 1.68; DP-SM 1.78, SX-M1; SX-M1 1.43; SX-M1 1.51, SX-M; SX-MTD; SX-MTD3, TSKs; SX-M; 1998-2005, TSKs; SX-M; 2006-2008
3857857
 
3857857 Anode
DP-SM; DP-SM 1.68; DP-SM 1.78, SX-M1; SX-M1 1.43; SX-M1 1.51, SX-M; SX-MTD; SX-MTD3, TSKs; SX-M; 1998-2005, TSKs; SX-M; 2006-2008
3852970
Anode, prop shaft housing
3852970 Anode, prop shaft housing
SX-C; SX-C1; SX-C2, SX-S; SX-SLT; SX-ST
3587782
 
3587782 Anode kit
TSKs; SX-M; 1998-2005, TSKs; SX-M; 2006-2008
Back to top