3801226 Volvo.Penta Aquamatic drive, exc, complete


3801226 Aquamatic drive, exc, complete Volvo.Penta DPH-A; TSK DPH-B; TSK DPH-A Aquamatic
3801226 Aquamatic drive, exc, complete Volvo Penta
Rating:
18

Buy Aquamatic drive, exc, complete 3801226 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 1
 

Compatible models:

Volvo Penta entire parts catalog list:

DPH-A; TSK DPH-B; TSK DPH-A; DPH-C; DPR-A; DPR-B

Information:


Table 1
Diagnostic Codes for Cooling Fan Control
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
4212-5 291-5 Engine Cooling Fan Solenoid : Current Below Normal The Electronic Control Module (ECM) detects an open circuit in the circuit for the engine fan control solenoid.
The ECM sends minimum current to the fan control solenoid. The code is logged.
4212-6 291-6 Engine Cooling Fan Solenoid : Current Above Normal The ECM detects a short circuit to ground in the circuit for the engine fan control solenoid.
The ECM sends minimum current to the fan control solenoid. The code is logged.
- 1076-5 Engine Cooling Fan Bypass Solenoid : Current Below Normal The Electronic Control Module (ECM) detects an open circuit in the circuit for the engine cooling fan bypass solenoid.
The ECM sends minimum current to the fan control solenoid. The code is logged.
- 1076-6 Engine Cooling Fan Bypass Solenoid : Current Above Normal The ECM detects a short circuit to ground in the circuit for the engine cooling fan bypass solenoid.
The ECM sends minimum current to the fan bypass solenoid. The code is logged. The ECM monitors engine coolant temperature, intake manifold air temperature, and hydraulic oil temperature. The ECM monitors the sensors in order to determine the correct speed for the engine cooling fan.The ECM controls the speed of the fan by controlling the current to the engine fan control solenoid. The engine fan control solenoid controls the amount of pressure to the fan motor by allowing oil to bypass the fan motor. The fan pump drives the fan. When the ECM outputs minimum current to the engine fan control solenoid, less oil is bypassed. The fan motor will now drive the fan at a higher rpm. When the ECM outputs maximum current to the engine fan control solenoid, more oil is bypassed. The fan motor will now drive the fan at a lower rpm.If the ECM detects a system fault, the ECM provides minimum current to the solenoid. Minimum current ensures a maximum fan speed while the fault condition exists.An override is available in the electronic service tool. The override allows the fan to be manually changed from the minimum to the maximum rpm.The cooling fan bypass solenoid prevents operation of the fan when the engine is cold. When the engine has warmed up, the solenoid will open the valve to allow hydraulic pressure to flow to the fan motor.During the following procedure, refer to the electrical schematic for the application.Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Check for Active Diagnostic Codes
A. Remove the electrical power from the ECM.
B. Verify that the solenoid connectors are free of debris and connected securely.
C. Connect the electronic service tool to the diagnostic connector.
D. Restore the electrical power to the ECM.
E. Select diagnostic tests on the electronic service tool.
F. Select the "Override Parameters" screen.
G. Activate the fan override.
H. Monitor the active diagnostic code screen on the electronic service tool. Check and record any active diagnostic codes. Wait at least 30 seconds in order for the diagnostic code to become active.
I. Disable the fan override.
Active Diagnostic Codes
Result: No diagnostic codes are active.
The problem may have been related to a faulty connection in the harness. Carefully inspect the connectors and wiring. Refer to Troubleshooting, "Electrical Connectors - Inspect".
Result: A 4212-6 or 291-6 code is active at this time.
Proceed to Test Step 2.
Result: A 4212-5 or 291-5 code is active at this time.
Proceed to Test Step 3.
Result: A 1076-6 code is active at this time.
Proceed to Test Step 4.
Result: A 1076-5 code is active at this time.
Proceed to Test Step 5.
2. Disconnect the Connector for the Engine Fan Control Solenoid in Order to Create an Open Circuit
A. Remove the electrical power from the ECM.
B. Disconnect the connector for the engine fan control solenoid.
C. Restore the electrical power to the ECM.
D. Activate the fan override.
E. Monitor the active diagnostic code screen on the electronic service tool. Check and record any active diagnostic codes. Wait at least 30 seconds in order for the diagnostic code to become active.
F. Disable the fan override.
Short circuit
Result: A 4212-6 or 291-6 code remains active. There is a short circuit between the harness connector for the engine fan control solenoid and the ECM.
Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Reset all active codes and clear all logged codes. Verify that the fault is resolved.
Result: A 4212-6 or 291-6 code was active before disconnecting the connector. A 4212-5 or 291-5 code became active after disconnecting the connector.
Repair: Replace the engine fan control solenoid. Reset all active codes and clear all logged codes. Verify that the fault is resolved.
If the


Parts aquamatic Volvo Penta:

3888874
 
3888874 Aquamatic drive, complete
DPH-A; TSK DPH-B; TSK DPH-A
3862822
 
3862822 Aquamatic drive, complete
DPH-A; TSK DPH-B; TSK DPH-A
3801120
 
3801120 Aquamatic drive, exc, complete
DPH-A; TSK DPH-B; TSK DPH-A
21661427
 
21661427 Aquamatic drive, complete
DPH-A; TSK DPH-B; TSK DPH-A
21661428
 
21661428 Aquamatic drive, complete
DPH-A; TSK DPH-B; TSK DPH-A
21661429
 
21661429 Aquamatic drive, complete
DPH-A; TSK DPH-B; TSK DPH-A
21661430
 
21661430 Aquamatic drive, complete
DPH-A; TSK DPH-B; TSK DPH-A
21550236
 
21550236 Aquamatic drive
DPH-A; TSK DPH-B; TSK DPH-A
Back to top