Illustration 1 g00479965
System Schematic For Starting Motor Relay (SMR)The GSC+ uses the starting motor relay (SMR) to activate the starting motor magnetic switches ("SMMS1" and "SMMS2") and the battery charger. The SMR is located within the relay module. "SMMS1" and "SMMS2" are located on the subpanel within the control panel.Note: Whenever the GSC+ activates the SMR, "K4" is shown on the lower display. "K4" is also shown on the lower display when the GSC+ attempts to activate the crank terminate relay. When the SMR is not activated, "K4" is not shown.ProcedureThe possible cause of this diagnostic code is an open coil or a shorted coil of the SMR.The following response is the system response to this fault while the SMR is activated:
If a CID 444 occurs, then the engine stops cranking.The following response is the system response to this fault while the SMR is not activated:
If a CID 444 occurs, then the engine cannot crank or the engine cannot start. If the engine is already running, then the engine continues to run.The GSC+ treats a CID 444 as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed. Also, the active alarm faults are shown when the ECS is in any position except the OFF/RESET position. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the status of the diagnostic code (Active/Inactive).
Turn the ECS to OFF/RESET and then turn the ECS to STOP.
Press the alarm codes key.
Observe the upper display. Check that a CID 444 FMI 12 is showing.
If the diagnostic code is not showing, enter the service mode. View the fault log (OP1). Check that the diagnostic code is showing. Expected Result: A CID 444 FMI 12 is showing as a active fault or an inactive fault. Results:
OK: A CID 444 FMI 12 has not occurred. The fault is NOT active and the fault is NOT inactive. STOP.
NOT OK: A CID 444 FMI 12is active or inactive. Proceed to 2.
Check internal cable of relay module. Note: Only open the relay module in a dry environment. If the inspection takes more than twenty minutes replace the desiccant bag in the GSC+ housing. See Testing And Adjusting, "Relay Module - Replace".
Turn the ECS to OFF/RESET.
Temporarily, remove the relay module from the GSC+. See Testing And Adjusting, "Relay Module - Replace".
Check the cable that attaches the relay module to the GSC+. Expected Result: The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged. Results:
OK: Reassemble the relay module to the GSC+. Proceed to 3.
NOT OK: Replace the connector clamp if the clamp is missing. If the cable is damaged, replace the GSC+. STOP.
Perform a functional check for the SMR.
Turn the ECS to OFF/RESET.
Disconnect all wires from RM-18 of the relay module.
Remove the fuse "F4" from the relay module.
At the relay module, measure the resistance from RM-18 to RM-6. Resistance should be greater than 5000 ohms.
Prepare to measure the resistance from RM-18 to RM-6 of the relay module.
Turn the ECS to the START position. Quickly measure the resistance before the starting motor relay deactivates because of the crank time. Resistance should be less than 5 ohms.Expected Result: For 3.d, the resistance should be greater than 5000 ohms. For 3.f, the resistance should be less than 5 ohms.Results:
OK: There was probably a poor electrical connection and performing this procedure corrected the poor connection. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". STOP.
NOT OK: Either one of the resistance measurements are NOT correct. The relay module is faulty. Replace the relay module. See Testing And Adjusting, "Relay Module - Replace". STOP.


Parts belt Volvo Penta:

8658108
 
8658108 Belt protector
D3-110I-D; D3-110I-E; D3-110I-F
8658107
 
8658107 Belt protector
D3-110I-D; D3-110I-E; D3-110I-F
30757554
 
30757554 Belt protector
D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G
21424647
 
21424647 Belt tensioner
D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H
31316674
 
31316674 Belt tensioner
D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G
22707408
 
22707408 Belt tensioner
D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G
21826866
 
21826866 Belt tensioner
D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H
31316752
 
31316752 Belt protector
D3-110I-G; D3-140A-G; D3-140I-G
Back to top