20826696 Volvo.Penta Bracket


20826696 Bracket Volvo.Penta TAD750VE; TAD760VE Bracket

Buy Bracket 20826696 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 27
 

Compatible models:

TAD750VE; TAD760VE   Volvo.Penta

Volvo Penta entire parts catalog list:

TAD750VE; TAD760VE

Information:


Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Note: Reclaim the refrigerant before any lines are loosened or any bolts are loosened.
Reclaim the refrigerant in the air conditioning system.ReferenceRefer to Testing and Adjusting, "Refrigerant Recovery" for the correct procedure.
Illustration 1 g01334489
Open the side door (1) .
Illustration 2 g00705026
Disconnect two hose assemblies (3) from refrigerant condenser (2) .
Remove two bolts (5) and the clamps from the mounting bracket.
Remove two bolts (1) , two washers, and two nuts from the mounting bracket.
Remove two bolts (4) and washers from refrigerant condenser (2) .
Illustration 3 g00705040
Remove four bolts (7) and washers from the two mounting brackets (6) .Installation Procedure
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Illustration 4 g00705040
Position two mounting brackets (6) onto the condenser. Install the washers and four bolts (7) .
Illustration 5 g00705026
Install washers and two bolts (4) to the refrigerant condenser (2) .
Install two nuts, two washers, and two bolts (1) to the mounting bracket.
Connect two hose assemblies (3) to refrigerant condenser (2) .
Install the clamps and two bolts (5) that hold hose assemblies (3) to the mounting bracket.
Illustration 6 g01334489
Close the side door (1) .
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a


Parts bracket Volvo Penta:

20723978
 
20723978 Bracket, front
TAD520GE; TAD720GE; TAD721GE, TAD520VE; TAD720VE; TAD721VE, TAD550GE; TAD551GE; TAD750GE, TAD650VE; TAD660VE, TAD750VE; TAD760VE, TD420VE; TAD420VE; TAD620VE, TD520GE; TAD530GE; TAD531GE
20723984
 
20723984 Bracket, front
TAD520GE; TAD720GE; TAD721GE, TAD520VE; TAD720VE; TAD721VE, TAD550GE; TAD551GE; TAD750GE, TAD650VE; TAD660VE, TAD750VE; TAD760VE, TD420VE; TAD420VE; TAD620VE, TD520GE; TAD530GE; TAD531GE
20460090
 
20460090 Bracket
TAD520VE; TAD720VE; TAD721VE, TAD650VE; TAD660VE, TAD750VE; TAD760VE
20593495
 
20593495 Bracket
TAD520VE; TAD720VE; TAD721VE, TAD750VE; TAD760VE
20714938
 
20714938 Bracket
TAD520VE; TAD720VE; TAD721VE, TAD650VE; TAD660VE, TAD750VE; TAD760VE
21457182
 
21457182 Bracket
TAD650VE; TAD660VE, TAD750VE; TAD760VE
21011793
 
21011793 Bracket
TAD750VE; TAD760VE
20797873
 
20797873 Bracket
TAD750VE; TAD760VE
Back to top