3838290 Bracket Volvo.Penta
D5A-T; D5A-TA; D5A-B TA, D5A-T; D5A-TA; D5A-B TA
Bracket
Price: query
Rating:
Compatible models:
D5A-T; D5A-TA; D5A-B TA
Volvo.Penta
Volvo Penta entire parts catalog list:
D5A-T; D5A-TA; D5A-B TA; D7A-T; D7A-TA; D7A-B TA; D7C-TA; D7C-B TA
Information:
Illustration 1 g00104545
Do not allow unauthorized personnel on the engine or around the engine when the engine is serviced.
Illustration 2 g00702020
Wear a hard hat, protective glasses, and other protective equipment, as required.
Tampering with the engine installation or tampering with the OEM supplied wiring can be dangerous. Personal injury, death and/or engine damage could result.
Vent the engine exhaust to the outside when the engine is operated in an enclosed area.
Do not release the secondary brake or the parking brake systems unless the vehicle is blocked or unless the vehicle is restrained.
When work is performed around an engine that is operating, wear protective devices for ears in order to help prevent damage to hearing.
Do not wear loose clothing or jewelry that can snag on controls or on other parts of the engine.
Ensure that all protective guards and all covers are secured in place on the engine.
Never put maintenance fluids into glass containers. Glass containers can break.
Use all cleaning solutions with care.
Report all necessary repairs.Unless other instructions are provided, perform the maintenance under the following conditions:
The engine is stopped. Ensure that the engine cannot be started.
The protective locks or the controls are in the applied position.
Engage the secondary brakes or parking brakes.
Block the vehicle or restrain the vehicle before maintenance or repairs are performed.
Disconnect the batteries when maintenance is performed or when the electrical system is serviced. Disconnect the battery ground leads. Tape the leads in order to help prevent sparks.
Disconnect the connector for the unit injector that is located on the valve cover base. This procedure will help prevent personal injury from the high voltage to the unit injectors. Do not come in contact with the unit injector terminals while the engine is operating.
Do not attempt any repairs or any adjustments to the engine while the engine is operating.
Do not attempt any repairs that are not understood. Use the proper tools. Replace any equipment that is damaged or repair the equipment.
When starting a new engine or an engine which has not been started since service has been performed, make provisions to stop the engine if an overspeed occurs. Shutting down the engine may be accomplished by shutting off the fuel supply and/or the air supply to the engine.
Start the engine from the operator station (cab). Never short across the starting motor terminals or the batteries which could bypass the engine neutral start system and/or the electrical system could be damaged.Cautiously remove the following parts:Note: To help prevent spraying or splashing of pressurized fluids, hold a rag over the part that is being removed.
Filler caps
Grease fittings
Pressure taps
Breathers
Drain plugsUse caution when cover plates are removed. Gradually loosen but do not remove the last two bolts or nuts that are located at opposite ends of the cover plate or the device. Before removing the last two bolts or nuts, pry the cover loose in order to relieve any spring pressure or other pressure.Pressurized Air and Water
Pressurized air and/or water can cause debris and/or hot water to be blown out which could result in personal injury.When pressurized air and/or pressurized water is used for cleaning, wear protective clothing, protective shoes, and eye protection. Eye protection includes goggles or a protective face shield. The maximum air pressure for cleaning purposes must be reduced to 205 kPa (30 psi) when the air nozzle is deadheaded and used with effective chip guarding (if applicable) and personal protective equipment. The maximum water pressure for cleaning purposes must be below 275 kPa (40 psi). Always wear eye protection for cleaning the cooling system.Fluid Penetration
Illustration 3 g00687600
Always use a board or cardboard when you check for a leak. Leaking fluid that is under pressure can penetrate body tissue. Fluid penetration can cause serious injury and possible death. A pin hole leak can cause severe injury. If fluid is injected into your skin, you must get treatment immediately. Seek treatment from a doctor that is familiar with this type of injury.Containing Fluid Spillage
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Caterpillar Dealer Service Tool Catalog" or refer to Special Publication, PECJ0003, "Caterpillar Shop Supplies and Tools Catalog" for tools and supplies suitable to collect and contain fluids on Caterpillar products.Dispose of all fluids according to local regulations and mandates.
Inhalation
Illustration 4 g02159053
Exhaust
Use caution. Exhaust fumes can be hazardous to your health. If you operate the equipment in an enclosed area, adequate ventilation is necessary.Asbestos Information
Caterpillar equipment and replacement parts that are shipped from Caterpillar are asbestos free. Caterpillar recommends the use of only genuine Cat replacement parts. Use the following guidelines when you handle any replacement parts that contain asbestos or when you handle asbestos debris.Use caution. Avoid inhaling dust that might be generated when you handle components that contain asbestos fibers. Inhaling this dust can be hazardous to your health. The components that may contain asbestos fibers are brake pads, brake bands, lining material, clutch plates, and some gaskets. The asbestos that is used in these components is usually bound in a resin or sealed in some way. Normal handling is not hazardous unless airborne dust that contains asbestos is generated.If dust that may contain asbestos is present, there are several guidelines that should be followed:
Never use compressed air for cleaning.
Avoid brushing materials that contain asbestos.
Avoid grinding materials that contain asbestos.
Use a wet method in order to clean up asbestos materials.
A vacuum cleaner that is equipped with a high efficiency particulate air filter (HEPA) can also be used.
Use exhaust ventilation on permanent machining jobs.
Wear an approved respirator if there is no other way to control the dust.
Comply with applicable rules and regulations for the work place. In the United States, use Occupational Safety and Health Administration (OSHA) requirements. These OSHA requirements can be found in "29 CFR 1910.1001".
Obey environmental regulations for the disposal of asbestos.
Stay away from areas that might have asbestos particles in the air.
Parts bracket Volvo Penta:
3836557
3838605
3838605 Bracket
D5A-T; D5A-TA; D5A-B TA, D5A-T; D5A-TA; D5A-B TA, TAD520GE; TAD720GE; TAD721GE, TD520GE; TAD530GE; TAD531GE
20460254
20460254 Bracket
D5A-T; D5A-TA; D5A-B TA, D5A-T; D5A-TA; D5A-B TA, TAD520GE; TAD720GE; TAD721GE, TAD520VE; TAD720VE; TAD721VE, TD520GE; TAD530GE; TAD531GE
20460411
3586484
3831156
3884205
3587735