Table 1
Diagnostic Trouble Codes
J1939 Code CDL Code Code Description Comments
3473-31 E1025 (2) Aftertreatment #1 Failed to Ignite The Aftertreatment Regeneration Device (ARD) has failed to ignite. Usually, the "failed to ignite" code is accompanied by another logged code that indicates the condition that caused the failure to ignite.
Follow the troubleshooting procedure to identify the root cause of the problem. Components for the Ignition SystemThe ignition coil is on the Clean Emissions Module (CEM) mounting plate. Refer to Illustration 1.
Illustration 1 g06125618
CEM (typical)
(1) Electrical connector to ECM
(2) Relay for the ARD nozzle heater
(3) ARD ignition coil
(4) ARD combustion headSystem OperationThe ARD ignition system has two circuits. The primary circuit is between the ECM and the ARD ignition coil. The secondary circuit is between the ARD ignition coil and the ARD spark plug. The current flow through the primary circuit indicates the condition of the primary circuit and of the secondary circuit. The ECM monitors the current flow through the primary circuit. In this way, the ECM is able to detect problems with the primary circuit and the secondary circuit.Complete the procedure in the order in which the steps are listed.
Table 2
Associated Diagnostic Trouble Codes
J1939 Code CDL Code
102-18 E1045 (2)
3487-7 E1041 (1)
3480-15 E1050 (1)
3480-16 E1050 (2)
3480-17 E1052 (1)
3484-5 2465-5
3484-6 2465-6
3480-18 E1052 (2)
3556-7 E1070 (1)
4265-5 3180-5
4265-6 3180-6
No associated codes A problem with the ignition circuit is the most likely cause of a logged E1025 (2) or 3473-31 code with no additional codes.
Table 3
Troubleshooting Test Steps Values Results
1. Check for Associated Codes
A. Establish communication between the electronic service tool and the Electronic Control Module (ECM).
B. If any of the associated codes in Table 2 are logged, troubleshoot the codes before continuing with this procedure.
Associated Codes
Result: An associated code is active or logged.
Repair: Troubleshoot the associated codes before continuing with this procedure.
Result: An associated code is not active or logged.
Proceed to Test Step 2.
2. Inspect the Components
Carefully following this procedure is a good way to identify wiring problems.
A. Visually inspect the components for the ARD ignition system. Look for the following problems:
1. Loose connections or damaged connectors
2. Moisture on the connectors or the wiring
3. Damage that is caused by excessive heat
4. Damage that is caused by chafing
5. Improper routing of wiring
6. Damaged insulation
B. Verify that each end of the ground wire is securely connected to both ground points.
C. Push the boot on each end of the ignition wire. This action tests whether the clip inside the boot is connected to the spark plug and to the ignition coil. There should not be a "click" when you push the boot onto either part. If you felt a "click", the clip inside the boot was not connected.
D. Pull on the end of each harness wire at the 3-pin connector for the ignition coil. This test verifies that the wire is crimped to the terminal and that the terminal is inserted into the connector.
Damaged wiring or connectors
Result: There is a problem with the wiring. A wire end is not connected or a wire is damaged.
Repair: Repair the wiring. Replace parts, if necessary.
Verify that the problem is resolved. If the problem is not resolved, proceed to Troubleshooting, "ARD Ignition - Test".
Result: The wiring is OK.
Proceed to Test Step 3.
3. Check the Current Flow to the Heating Element in the ARD Combustion Head
Start the engine. Check the current flow to the heater. Refer to Systems Operation/Testing and Adjusting, "ARD Nozzle Heater (Current)- Test" for the correct procedure.
7.0 A to 14.0 A for a 12 V system
or
3.5 A to 7.0 A for a 24 V system
Result: The current flow is not between 7.0 A and 14.0 A for a 12 V system. The current flow is not between 3.5 A and 7.0 A for a 24 V system.
Repair: There may be a problem with the ARD nozzle. Refer to Troubleshooting, "ARD Nozzle Heater - Test".
Result: The current flow is between 7.0 A and 14.0 A for a 12 V system. The current flow is between 3.5 A and 7.0 A for a 24 V system.
The current flow is OK.
Proceed to Test Step 4.
4. Perform the "ARD Air System Service Test"
A. Reset all active codes and clear all logged codes. Use the electronic service tool to perform an "ARD Air System Service Test". Refer to Troubleshooting, "ARD Combustion Air - Test".
Test passed
Result The "ARD Air System Service Test" failed.
Repair: There is a problem with the ARD combustion air. Refer to Troubleshooting, "ARD Combustion Air - Test".
Result The "ARD Air System Service Test" passed.
Proceed to Test Step 5.
Illustration 2 g06125649
368-6232 Spark Indicator
(5) Connector for spark plug
(6) Spark window
(7) Connector for HT ignition lead
Table 4
Troubleshooting Test Steps Values Results
5. Check for Spark Voltage at the Spark Plug
A. Disconnect the ignition wire from the spark plug.
B. Connect the 368-6232 Spark Indicator between ign


Parts bracket Volvo Penta:

842767
 
842767 Bracket
2001; 2001B; 2001AG, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ205A; AQ205LB, AQ211A; DP-A; SP-A, AQ231A; AQ231B; AQ231LB, AQ271A; AQ271B; A
860611
 
860611 Bracket
AD31D; AD31D-A; AD31XD, AD41D; D41D; TAMD41D, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, MD31A; TMD31B; TAMD31B, TMD41B; D41B; TAMD41B
3581698
 
3581698 Bracket
AD31L-A; AD31P-A; AD41L-A, KAD32P; TAMD42WJ-A; KAD43P-A
3580758
 
3580758 Bracket
AD31L-A; AD31P-A; AD41L-A, KAD32P; TAMD42WJ-A; KAD43P-A, KAD42P-A; KAMD42P-A; HS1A
834974
Bracket
834974 Bracket
AD31L-A; AD31P-A; AD41L-A, AQ175A, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A, AQ290A, KAD32P; TAMD42WJ-A; KAD43P-A, KAD42P-A; KAMD42P-A; HS1A, TD610G; TWD610G; TD710G, TD71A; TID71A; TWD710V
856768
Bracket
856768 Bracket
430; 430A; 430B, 740A; BB740A, D3-110I-A; D3-110I-B; D3-110I-C, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F, KAD32P; TAMD42WJ-A; KAD43P-A, KAD42A; KAMD42A; HS1A, K
3581466
 
3581466 Bracket
KAD32P; TAMD42WJ-A; KAD43P-A
3581402
Bracket
3581402 Bracket
KAD32P; TAMD42WJ-A; KAD43P-A, KAD42P-A; KAMD42P-A; HS1A
Back to top