965540 Bracket Volvo.Penta
D11A-A; D11A-B; D11A-C, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D16C-A MG, D16C-D MH, D5A-T; D5A-TA; D5A-B TA, D9A2A; D9A2A MG; D9A2A D9A-MG, DH10A; DH10A 285; DH10A 360, MD100A; TMD100A; TMD100AK, TAD1240GE; TAD1241GE; TAD1242GE, TAD1
Bracket
Price: query
Rating:
Compatible models:
D11A-A; D11A-B; D11A-C
D12D-A MG; D12D-E MG
D12D-A MH; D12D-B MH; D12D-C MH
D16C-A MG
D16C-D MH
D5A-T; D5A-TA; D5A-B TA
D9A2A; D9A2A MG; D9A2A D9A-MG
DH10A; DH10A 285; DH10A 360
MD100A; TMD100A; TMD100AK
TAD1240GE; TAD1241GE; TAD1242GE
TAD1630P; TWD1630P; TWD1630PP
TAD1630V; TWD1630V
TAMD103A
TAMD122A; TMD122A; TAMD122P-A
TAMD162C-C; TAMD163A-A; TAMD163P-A
TAMD165A; TAMD165C; TAMD165P
TAMD71B; TAMD73P-A; TAMD73WJ-A
TAMD72P-A; TAMD72WJ-A
TAMD74A; TAMD74A-A; TAMD74A-B
TD164KAE
TD610M; TD630ME; TWD630ME
TD610V; TWD610V; TD630VE
TD61A; TD61AW; TD61ACE
TD71A; TID71A; TWD710V
TID162AG; TID162AGP; TID162AP
TWD1240VE; TAD1241VE; TAD1242VE
TWD1620G; TWD1630G; TAD1630G
TWD610P; TWD610PB; TWD710P
Volvo.Penta
Volvo Penta entire parts catalog list:
- Compressor IPS » 965540
D12D-A MH; D12D-B MH; D12D-C MH; D12D-E MH; D12D-G MH; D12C-A MP; D12D-A MP; D12D-B MP; D12D-C MP; D12D-D MP; D12D-E MP; D12D-F MP; D12D-G M
D16C-A MG
D16C-D MH
D5A-T; D5A-TA; D5A-B TA; D7A-T; D7A-TA; D7A-B TA
D9A2A; D9A2A MG; D9A2A D9A-MG
DH10A; DH10A 285; DH10A 360; DH10A Rail; THD102KD; THD102KB
- Fuel System, SN1201090022-
- Fuel System: A
- Fuel System: A
- Fuel System: B
- Fuel System: B
- Turbocharger: A
- Turbocharger: B
- Turbocharger: C
TAD1240GE; TAD1241GE; TAD1242GE
TAD1630P; TWD1630P; TWD1630PP; TAD1630PB
TAD1630V; TWD1630V
TAMD103A
TAMD122A; TMD122A; TAMD122P-A; TAMD122P-B; TAMD122P-C; TMD122A/C; TAMD122AF
TAMD162C-C; TAMD163A-A; TAMD163P-A
TAMD165A; TAMD165C; TAMD165P; TAMD165A-A; TAMD165C-A; TAMD165P-A
TAMD71B; TAMD73P-A; TAMD73WJ-A
TAMD72P-A; TAMD72WJ-A
TAMD74A; TAMD74A-A; TAMD74A-B; TAMD74C-A; TAMD74C-B; TAMD74L-A; TAMD74L-B; TAMD74P-A; TAMD74P-B; TAMD75P-A
TD164KAE
TD610M; TD630ME; TWD630ME; TD730ME; TWD730ME; TWD731ME
TD610V; TWD610V; TD630VE; TWD630VE; TD640VE; TWD610PB
TD61A; TD61AW; TD61ACE; TD61AG; TD61AGP; TD61AP; TD61APB; TID61AG; TD71A; TD71AW; TD71ACE; TD71AG; TD71AGP; TD71AP; TD71APB; TID71A; TID71AG; TID
TD71A; TID71A; TWD710V; TD730VE; TWD731VE; TAD730V; TWD740VE
TID162AG; TID162AGP; TID162AP; TID162APB
TWD1240VE; TAD1241VE; TAD1242VE; TAD1250VE; TAD1251VE; TAD1252VE
TWD1620G; TWD1630G; TAD1630G; TAD1630GE; TAD1631G; TAD1631GE
TWD610P; TWD610PB; TWD710P; TWD710PB; TAD730P
Information:
Illustration 1 g02280216RTD Module Features
The RTD module contains the following features:
Capable of reading eight platinum RTD inputs
All 8 channels scanned in 2 seconds, 250 ms per channel
Inputs can have two, three, or four wire configurations
Calculate the temperature in degree Centigrade
Broadcast temperature information onto the CAN data link
Capable of generating diagnostics
Overall drift with temperature is 15m ohm per degree Centigrade (maximum)
Maintains functionality with no loss in performance during single set point configuration
Maintains functionality with no loss in performance during communications on the data link
Will continue to operate normally if the communication data link is terminated
Retains all configured values in nonvolatile memory so that no information is lost when the module is de-energized
Configured on the accessory CAN data link using the Cat ET
Operates on the ECM (primary) CAN data links
Node address is automatically configuredNote: The four wire configuration is the most accurate. The four wire configuration uses one pair of wires for the excitation current and a separate pair of wires to measure the voltage.The MGCP will read the information from the RTD module and display the information on the display screen.The diagnostics that are generated by the RTD module are maintained in non-volatile memory. The diagnostics are saved to ensure that the diagnostics are available following a power loss.Specifications
Table 1
RTD Specifications
Operating voltage range 5 VDC to 32 VDC
Nominal voltage 12 VDC or 24 VDC
Overvoltage capability 32 VDC for 1 hour at 85 °C (185 °F)
Ambient storage temperature −50 °C (−58 °F) to 125 °C (257 °F)
Ambient operating temperature range(1)(2) −40 °C (−40 °F) to 120 °C (248 °F)
Optical isolation(3) 500 VDC from input to ground
Burden less than 200 mA
Inrush not to exceed 800 mA
(1) If the ambient temperatures exceed 85 °C (185 °F), the RTD module may deviate in accuracy +/- 1°C.
(2) If the ambient temperature exceeds 120 °C (248 °F), the RTD module may not return to proper operation.
(3) Three-way isolation is provided for the CAN line, inputs, and power supply.Note: Power supply inputs are protected against transient surges and short circuits. Power supply inputs are isolated from I/O modules.RTD Wiring
Illustration 2 g06244892
Power and CAN bus connector wiring
Illustration 3 g02280295
Typical RTD sensor wiring
Illustration 4 g02280333
Typical RTD wiring connections
RTD Module Configuration
RTD modules can be programmed the use of Cat ET. Cat ET can also be used to flash program RTD modules to update software. Cat ET must be installed on a Windows based personal computer. The communication adapter must be connected between the PC and the CAN data link on which the target RTD module is connected.Note: Cat ET may be connected to the ECM data link service connector.
Click the "RTD Module" (1) on the left side of the dialog. The information for the module will appear. Refer to Illustration 5.
Illustration 5 g02280354
Press "F5" or click the configuration tool icon on the dialog tool bar. Cat ET contains set points for configuring the RTD identification, and the RTD inputs.Configuring RTD Inputs
Illustration 6 is an example that shows the configured values (3) for "RTD Input #1" (2). All eight RTD inputs have identical parameters and options.
Illustration 6 g02280956
RTD module summary screen
RTD Parameters and Options
Sensor Type Configuration - Selects between a two, three, or four wire configuration. Select the appropriate configuration based on the type of RTD sensor that is installed.Temperature Coefficient Configuration - Selects between an IEC Platinum, JIS Platinum, Legacy US Platinum, SA MA Platinum, or US Platinum type of RTD sensor. Select the appropriate configuration based on the type of RTD sensor that is installed.Suspect Parameter Number (SPN) - An SPN is a predetermined code that is used for troubleshooting. Each SPN contains a unique definition. All the RTD inputs support the same li
Parts bracket Volvo Penta:
354842
354842 Bracket
AD30A; AQAD30A; MD30A, D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D9A2A; D9A2A D9-425; D9A2A D9-500, DH10A; DH10A 285; DH10A 360, MD40A; TMD40A; TMD40B, TAMD103A, TAMD122A; TMD122A; TAMD122P-A, TAMD1
3838254
3838254 Bracket
D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D9A2A; D9A2A D9-425; D9A2A D9-500, D9A2A; D9A2A MG; D9A2A D9A-MG, TAD940GE; TAD941GE, TAD940VE; TAD941VE; TAD942VE
3829234
3818869
865376
3827951
847950
847950 Bracket
D12D-A MH; D12D-B MH; D12D-C MH, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P, TAMD61A; TAMD62A, TAMD71A; TAMD72A
3842484