873851 Volvo.Penta Cable kit


873851 Cable kit Volvo.Penta KAD32P; TAMD42WJ-A; KAD43P-A Cable
873851 Cable kit Volvo Penta
Rating:
38

Buy Cable kit 873851 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$56.46
 

05-01-2022
0.1[0.00] Pounds
-: -
Exact FIT for Hobart 873851 Plunger & Bearing Assembly - Replacement Part by MAVRIK
EQUIVALENT TO HOBART PART# 873851 || THIS IS THE EXACT FIT FOR HOBART 873851 || Mavrik OEM-equivalents -- your best choice for safety and reliability || Why pay more for OEM? Save time and money with Mavrik OEM-equivalents || This part is covered by manufacturer warranty
Number on catalog scheme: 9
 

Compatible models:

Volvo Penta entire parts catalog list:

KAD32P; TAMD42WJ-A; KAD43P-A; KAMD43P; KAMD43P-A; KAMD43P-B; KAD44P; KAD44P-B; KAD44P-C; KAMD44P-A; KAMD44P-C; KAD300-A; KAMD300-A; HS1A; HS1E

Information:


Table 1
"Fan Control Type" Is Programmed to "On/Off DC"
Output Terminal Signal When the Fan Is Off Signal When the Fan Is On
P1-21 Battery Voltage 0 VDC
P1-13 P1-13 is not used P1-13 is not used
Any of these conditions will cause the cooling fan to turn on Coolant temperature is greater than 102 °C (216 °F)
Inlet manifold temperature is greater than 87 °C (189 °F)
The A/C high pressure switch is On
The PTO on/off switch is On and the "PTO Activates Cooling Fan" parameter is programmed to "Continuous"
The manual fan override switch is On
The transmission requests the cooling fan to turn on via the J1939 data link
A stationary regeneration is in progress
There is an active diagnostic trouble code for the coolant temperature sensor
Table 2
"Fan Control Type" Is Programmed to "On/Off PWM"
Output Terminal Signal When the Fan Is Off Signal When the Fan Is On
P1-21 A PWM signal with a 90 percent duty cycle "OL"
P1-13 P1-13 is not used P1-13 is not used
Any of these conditions will cause the cooling fan to turn On Coolant temperature is greater than 102 °C (216 °F)
Inlet manifold temperature is greater than 87 °C (189 °F)
The A/C high pressure switch is On
The PTO on/off switch is On and the "PTO Activates Cooling Fan" parameter is programmed to "Continuous"
The manual fan override switch is On
The transmission requests the cooling fan to turn on via the J1939 data link
A stationary regeneration is in progress
There is an active diagnostic trouble code for the coolant temperature sensor
Table 3
"Fan Control Type" Is Programmed to "Three Speed Fan Option 1 DC"
Output Terminal Signal When the Fan Is in "Brake" Mode
(Off) Signal When the Fan Is in "Slip" Mode
(Medium Speed) Signal When the Fan Is in "Direct" Mode
(High Speed)
P1-21 Battery Voltage Battery Voltage 0 VDC
P1-13 Battery Voltage 0 VDC 0 VDC
Any of these conditions will cause the cooling fan to operate in the "Direct" mode The A/C high pressure switch is On
The PTO on/off switch is On and the "PTO Activates Cooling Fan" parameter is programmed to "Continuous"
The manual fan override switch is On
The transmission requests the cooling fan to turn on via the J1939 data link
A stationary regeneration is in progress
There is an active diagnostic trouble code for the coolant temperature sensor
Temperature Increase "Slip" mode is activated when the coolant temperature increases above 91 °C (196 °F) or the inlet manifold temperature increases above 52 °C (126 °F). "Direct" mode is activated when the coolant temperature increases above 102 °C (216 °F) or the inlet manifold temperature increases above 82 °C (180 °F).
Temperature Decrease "Slip" mode is activated when the coolant temperature falls below 96 °C (205 °F) and the inlet manifold temperature is less than 52 °C (126 °F). "Brake" mode is activated when the coolant temperature falls below 81 °C (178 °F) and the inlet manifold temperature is less than 39 °C (102 °F).
Table 4
"Fan Control Type" Is Programmed to "Three Speed Fan Option 1 PWM"
Output Terminal Signal When the Fan Is in "Brake" Mode
(Off) Signal When the Fan Is in "Slip" Mode
(Medium Speed) Signal When the Fan Is in "Direct" Mode
(High Speed)
P1-21 A PWM signal with a 90 percent duty cycle A PWM signal with a 90 percent duty cycle "OL"
P1-13 A PWM signal with a 90 percent duty cycle "OL" "OL"
Any of these conditions will cause the cooling fan to operate in the "Direct" mode The A/C high pressure switch is On
The PTO on/off switch is On and the "PTO Activates Cooling Fan" parameter is programmed to "Continuous"
The manual fan override switch is On
The transmission requests the cooling fan to turn on via the J1939 data link
A stationary regeneration is in progress
There is an ac


Parts cable Volvo Penta:

948211
 
948211 Cable tie
1372, 2001; 2001B; 2001AG, 3.0GLM-C; 3.0GLP-C, 3.0GLMMDA; 3.0GSPMDA, 3.0GLP-A; 3.0GLP-B; 3.0GLM-A, 3.0GLP-D, 3.0GLP-E, 3.0GLP-J; 3.0GLP-N, 3.0GSMBYMCE; 3.0GSPBYCCE, 3.0GSMHUB; 3.0GSPHUB, 3.0GSMLKD; 3.0GSPLKD, 3.0GSMNCA; 3.0GSMNCS; 3.0GSPNCA, 3.0GSMWT
940336
 
940336 Cable terminal
1372, 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7GiCE-300-J; 5.7GiCE-300-JF; 5.7GXiCE-J, 5.7GiE-300-J; 5.7GiE-300-JF; 5.7GXiE-J, 500; 500A; 501A, 571A, 740A
881488
Cable terminal
881488 Cable terminal
1372, 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7GiCE-300-J; 5.7GiCE-300-JF; 5.7GXiCE-J, 5.7GiE-300-J; 5.7GiE-300-JF; 5.7GXiE-J, 500; 500A; 501A, 571A, 740A
850361
 
850361 Cable attachment
230A; 230B; 250A, 251A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A, AQ
856865
 
856865 Cable kit
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, DP-C1; DP-D1; DP-S, DP-E; SP-E; TSK DP-E, DP-G; TSK DP-G, KAD32P; TAMD42WJ-A; KAD43P-A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P-A; HS1A
970788
 
970788 Cable terminal
1372, 430; 430A; 430B, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7GiCE-300-J; 5.7GiCE-300-JF; 5.7GXiCE-J, 5.7GiE-300-J; 5.7GiE-300-JF; 5.7GXiE-J, 8.1GiCE-J; 8.1GiCE-JF; 8.1GiCE-M, 8.1GiE-JF; 8.1GiE-J; 8.1OSiE-JF, 8.1IP
970789
 
970789 Cable terminal
1372, 430; 430A; 430B, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7GiCE-300-J; 5.7GiCE-300-JF; 5.7GXiCE-J, 5.7GiE-300-J; 5.7GiE-300-JF; 5.7GXiE-J, 8.1GiCE-J; 8.1GiCE-JF; 8.1GiCE-M, 8.1GiE-JF; 8.1GiE-J; 8.1OSiE-JF, 8.1IP
940334
Cable terminal
940334 Cable terminal
1372, 430; 430A; 430B, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7GiCE-300-J; 5.7GiCE-300-JF; 5.7GXiCE-J, 5.7GiE-300-J; 5.7GiE-300-JF; 5.7GXiE-J, 8.1GiCE-J; 8.1GiCE-JF; 8.1GiCE-M, 8.1GiE-JF; 8.1GiE-J; 8.1OSiE-JF, 8.1IP