835061 Volvo.Penta Camshaft


835061 Camshaft Volvo.Penta AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A Camshaft
835061 Camshaft Volvo Penta
Rating:
103

Buy Camshaft 835061 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$679.95
 

17-10-2023
16.0[7.20] pounds
-: -
Holley 835061 Holley Sniper Fabricated Intake Manifold Precision Fixtured And Welded For A Perfect Fit Dual 4150 Flange Silver Holley Sniper Fabricated Intake Manifold
Big Block Chevy || Single Plane 2 x 4150 || Silver Finish With Sniper Logo Features: || 1/8 in. T6061 sheet aluminum construction || 100 TIG welded seams
Number on catalog scheme: 1
 

Compatible models:

Volvo Penta entire parts catalog list:

AQ225D; AQ225E; AQ225F; BB225A; BB225AV; BB225B; BB225C; 275; 280B; 290A; 290DP; MS3B; MS3C; MS4A
AQ260A; AQ260B; BB260A; BB260AV; BB260B; BB260C

Information:


Illustration 1 g00584152
Wye Configuration Of External Potential Transformers (PT) On 4-Wire Wye Generator
This configuration allows the accurate measurement of all power parameters by the GSC+ including when the loads are unbalanced and neutral current is present. All power parameters are shown on the display of the GSC+.
Illustration 2 g00584153
Open Delta Configuration Of External Potential Transformers (PT) On The 3-Wire Delta Generator
This configuration allows the accurate measurement of power parameters by the GSC+ including when the loads are unbalanced and circulating current is present. The real power phase A, B and C can not be determined. The power factor phase A, B and C can not be determined. The phases are not shown on the GSC+ display.
Illustration 3 g00584154
Open Delta Configuration Of External Potential Transformers (PT) On The 4-Wire Wye Generator
This configuration results in less accurate measurement of all power parameters by the GSC+ when the loads are unbalanced and neutral current is present. Real power phase A, B, C and power factor phase A, B, C can not be determined and are not shown on the GSC+ display.
Note: The wye configuration of external potential transformers (PT's) is preferred for 4-wire wye generators because of the greater accuracy when loads are unbalanced. With the open delta configuration, some power parameters can not be determined. These parameters are real power phase A, B, C and power factor phase A, B, C. For maximum accuracy, the open delta configuration of external PT's should be used only for 3-wire delta generators.On 4-wire wye generators, three separate potential transformers (PT's) are required for accurate power metering unless the loads are completely and continually balanced. Even if the loads are balanced, some power parameters can not be determined. These parameters are not shown on the GSC+ display: real power phase A, B, C and power factor phase A, B, C. The ATB+ contains three potential transformers in order to accommodate 4-wire wye generators. The full capabilities of the ATB+ are not utilized when an open delta PT configuration is used for 4-wire wye generators.On 3-wire delta generators, two potential transformers allow maximum accuracy for all load conditions. However, again real power phase A, B, C and power factor phase A, B, C can not be determined and are not shown on the GSC+ display.The GSC+ must be programmed when connecting external PT's to the ATB+.Procedure For Programming When PT's Are Used
Program setpoint P032 in order to match the configuration of the external PT's. Setpoint P032 must always match the configuration of the external PT's regardless of whether the generator is a wye or delta. This is necessary because the ATB+ is connected only to the external PT's and cannot sense the generator connections.
For external PT's that are connected in a wye configuration, program setpoint P032 to 0 (wye). Setpoint P032 is also programmed to 0 when no PT's are present on wye generators.
For external PT's that are connected in a delta configuration, program setpoint P032 to 1 (delta). Setpoint P032 is also programmed to 1 when no PT's are present on delta generators.Note: When setpoint P032 is programmed to 1 (delta), real power phase A, B, C and power factor phase A, B, C can not be determined and are not shown on the GSC+ display.
Program setpoint P020 to match the turns ratio of the external PT's. See the AC Voltage Range Selection chart in Testing And Adjusting, "AC Voltage Range - Adjust". Setpoint P020 should match the turns ratio of the external PT's independent of whether setpoint P032 is programmed for wye or delta.


Parts camshaft Volvo Penta:

841423
Camshaft bearing
841423 Camshaft bearing
430; 430A; 430B, 500; 500A; 501A, 571A, AQ175A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ205A; AQ205LB, AQ211A; DP-A; SP-A, AQ225D; AQ225E; AQ225F, AQ231A; AQ231B; AQ231LB, AQ260A; AQ260B; BB260A, AQ271A; AQ271B; AQ271C, AQ290A
841424
 
841424 Camshaft bearing
430; 430A; 430B, 500; 500A; 501A, 571A, AQ175A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ205A; AQ205LB, AQ211A; DP-A; SP-A, AQ225D; AQ225E; AQ225F, AQ231A; AQ231B; AQ231LB, AQ260A; AQ260B; BB260A, AQ271A; AQ271B; AQ271C, AQ290A
841422
Camshaft bearing
841422 Camshaft bearing
430; 430A; 430B, 500; 500A; 501A, 571A, AQ175A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ205A; AQ205LB, AQ211A; DP-A; SP-A, AQ225D; AQ225E; AQ225F, AQ231A; AQ231B; AQ231LB, AQ260A; AQ260B; BB260A, AQ271A; AQ271B; AQ271C, AQ290A
835465
 
835465 Camshaft
430; 430A; 430B, 500; 500A; 501A, 571A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ211A; DP-A; SP-A, AQ225D; AQ225E; AQ225F, AQ231A; AQ231B; AQ231LB, AQ260A; AQ260B; BB260A, AQ271A; AQ271B; AQ271C, BB231A; BB261A
835546
 
835546 Camshaft chain
AQ175A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A
Back to top