242753 Coil Volvo.Penta
AQD70D; TAMD70D; TAMD70E, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAMD60A; TAMD60B, TAMD60C, TMD100C, TMD102A; TAMD102A; TAMD102D, TMD121C; TAMD121C; TAMD121D
Coil
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$1.38
11-04-2024
0.0485[0.02] Pounds
CN: Hkitriy
Dewedrt 1Pcs for K2-K7 Series High-Pressure Car Washing Machine Water Filter Connection Washers Eco-Friendly Thick Foam Sud
Dewedrt It works with any pressure washers, small and big all can work perfectly. || It can make soft snow foam, fun and simply. || It saves water, It's eco-friendly. || Brand new and high quality || It's touch-less car wash, it saves your time and energy
Dewedrt It works with any pressure washers, small and big all can work perfectly. || It can make soft snow foam, fun and simply. || It saves water, It's eco-friendly. || Brand new and high quality || It's touch-less car wash, it saves your time and energy
Compatible models:
Volvo Penta entire parts catalog list:
- Charging Relay » 242753
MD120A; MD120AK; TMD120A; TMD120AK; TAMD120A; TAMD120AK; TMD120B; TAMD120B; TAMD120B-CC
MD70B; MD70BK; TMD70B; THAMD70B; TAMD70B; AQD70BL; AQD70B
MD70C; TMD70C; TAMD70C; THAMD70C; AQD70BL; AQD70CL
TAMD60A; TAMD60B
TAMD60C
TMD100C
TMD102A; TAMD102A; TAMD102D
TMD121C; TAMD121C; TAMD121D; TAMD122C; TAMD122D
Information:
Table 1
Diagnostic Trouble Code    
CDL Code    Code Description    Comments    
E1008-1     High DPF #1 Intake Temperature : least severe (1)     There are no active 168 diagnostic codes.
The Aftertreatment Regeneration Device (ARD) has been running for at least 30 seconds. The temperature at the intake of the DPF rises above a temperature that is calculated by the ECM. The temperature threshold has been exceeded for 60 seconds.
The code is logged. The code remains active until electrical power to the ECM is cycled.    
E1008-2     High DPF #1 Intake Temperature : moderate severity (2)     There are no active 168 diagnostic codes.
The Aftertreatment Regeneration Device (ARD) has been running for at least 30 seconds. The temperature at the intake of the DPF rises above
690° C (1274° F) and the temperature then remains above
680° C (1256° F) for 60 seconds. These values are configurable.
Active regeneration is immediately disabled. Engine power is derated. The code is logged. The code remains active until electrical power to the ECM is cycled.    
Follow the troubleshooting procedure in order to identify the root cause of the fault.    Troubleshooting Procedure
Related Systems
Troubleshoot any faults that relate to the following systems or conditions:
Low output pressure from the turbochargers
Aftertreatment Regeneration Device (ARD)
NOx Reduction System (NRS)Troubleshoot the systems in the order that is listed above if there are faults in more than one of the systems. If no faults are apparent, refer to "DPF".DPF
Remove the inlet section from the DPF. Inspect the inside of the inlet section and the front face of the DPF for excessive ash.A small amount of ash is a normal condition. If the amount of ash is considered to be excessive, contact the Caterpillar technical communicator. Continue with this procedure after guidance has been received.
Inspect the inside of the inlet section and the front face of the DPF for oil.If oil is found, inspect the outlet of the turbochargers. If oil is found, contact the technical communicator at a Caterpillar dealer. Continue with this procedure after guidance has been received.
Clean the oil from the inside of the inlet section of the DPF and the front face of the DPF. Assemble the DPF. Run the engine at 1400 rpm for 15 minutes.Electronic Unit Injectors
If no oil is found in the previous test step, leave the inlet section disconnected from the DPF. Use the electronic service tool to disable the ARD. Set the value of the "Data Link ARD Disable Status" configuration parameter to "Disabled" in order to disable the ARD.
Perform a manual cylinder cutout test. Manually cut out each cylinder while the exhaust is monitored for excessive smoke. Check whether the smoke disappears as each cylinder is cut out. Replace any injectors that cause the engine to smoke and run rough when the cylinder is not cut out.
Clean the inside of the inlet section of the DPF and the front face of the DPF.
Assemble the DPF.
Set the value of the "Data Link ARD Disable Status" configuration parameter to "Not Disabled" in order to enable the ARD. Then, proceed to the next test step.
Run the engine at 1400 rpm for 15 minutes.
Use the electronic service tool to perform a DPF regeneration.If the fault is still present, contact the technical communicator at a Cat dealer.
Parts coil Volvo Penta:
242735
242735 Coil
AQD70D; TAMD70D; TAMD70E, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAMD60A; TAMD60B, TAMD60C, TMD100C, TMD102A; TAMD102A; TAMD102D, TMD121C; TAMD121C; TAMD121D
242754
242754 Coil
AQD70D; TAMD70D; TAMD70E, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAMD60A; TAMD60B, TAMD60C, TMD100C, TMD102A; TAMD102A; TAMD102D, TMD121C; TAMD121C; TAMD121D