829065 Volvo.Penta Companion flange


829065 Companion flange Volvo.Penta AQ115A; AQ115B; AQ130, MD21B; AQD21B Companion
829065 Companion flange Volvo Penta
Rating:
23

Buy Companion flange 829065 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 49
 

Compatible models:

Volvo Penta entire parts catalog list:

AQ115A; AQ115B; AQ130; AQ130A; AQ130B; AQ130C; AQ130D; AQ165A; AQ170A; AQ170B; AQ170C; AQD21A; BB115A; BB115B; BB115C; BB165A; BB170A; BB170B; BB1
MD21B; AQD21B

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
5966-5
Aftertreatment #1 DEF Control Module Power Supply : Current Below Normal 3965-5
Aftertreatment #1 Diesel Exhaust Fluid Control Module Power Supply #1 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the Selective Catalyst Reduction (SCR) System and the Diesel Exhaust Fluid Control Unit (DCU).
5966-6
Aftertreatment #1 DEF Control Module Power Supply : Current Above Normal 3965-6
Aftertreatment #1 Diesel Exhaust Fluid Control Module Power Supply #1 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
5968-5
Aftertreatment #2 DEF Control Module Power Supply : Current Below Normal 4801-5
Aftertreatment #2 DEF Controller #1 Power Supply #1 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the Selective Catalyst Reduction (SCR) System and the Diesel Exhaust Fluid Control Unit (DCU).
5968-6
Aftertreatment #2 DEF Control Module Power Supply : Current Above Normal 4801-6
Aftertreatment #2 DEF Controller #1 Power Supply #1 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
6309-5
Aftertreatment #1 DEF Control Module #1 Power Supply #2 : Current Below Normal 3966-5
Aftertreatment #1 Diesel Exhaust Fluid Control Module Power Supply #2 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
6309-6
Aftertreatment #1 DEF Control Module #1 Power Supply #2 : Current Above Normal 3966-6
Aftertreatment #1 Diesel Exhaust Fluid Control Module Power Supply #2 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR and the DCU.
6310-5
Aftertreatment 2 Diesel Exhaust Fluid Control Module 1 Power Supply 2 : Current Below Normal 4802-5
Aftertreatment #2 DEF Controller #1 Power Supply #2 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
6310-6
Aftertreatment 2 Diesel Exhaust Fluid Control Module 1 Power Supply 2 : Current Above Normal 4805-6
Aftertreatment #2 DEF Controller #1 Power Supply #2 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR and the DCU.
7522-5
Aftertreatment #1 DEF Control Module #2 Power Supply #1 : Current Below Normal 4799-5
Aftertreatment #1 Diesel Exhaust Fluid Controller #2 Power Supply #1 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7522-6
Aftertreatment #1 DEF Control Module #2 Power Supply #1 : Current Above Normal 4799-6
Aftertreatment #1 Diesel Exhaust Fluid Controller #2 Power Supply #1 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7523-5
Aftertreatment #1 DEF Control Module #2 Power Supply #2 : Current Below Normal 4800-5
Aftertreatment #1 Diesel Exhaust Fluid Controller #2 Power Supply #2 : Current Above Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7523-6
Aftertreatment #1 DEF Control Module #2 Power Supply #2 : Current Above Normal 4800-6
Aftertreatment #1 Diesel Exhaust Fluid Controller #2 Power Supply #2 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7533-5
Aftertreatment 2 Diesel Exhaust Fluid Control Module 2 Power Supply 1 : Current Below Normal 4803-5
Aftertreatment #2 DEF Controller #2 Power Supply #1 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7533-6
Aftertreatment 2 Diesel Exhaust Fluid Control Module 2 Power Supply 1 : Current Above Normal 4803-6
Aftertreatment #2 DEF Controller #2 Power Supply #1 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7534-5
Aftertreatment 2 Diesel Exhaust Fluid Control Module 2 Power Supply 2 : Current Below Normal 4804-5
Aftertreatment #2 DEF Controller #2 Power Supply #2 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7534-6
Aftertreatment 2 Diesel Exhaust Fluid Control Module 2 Power Supply 2 : Current Above Normal 4804-6
Aftertreatment #2 DEF Controller #2 Power Supply #2 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
Illustration 1 g06300380
The DCUs are on the sides of the Pump Electronic Tank Unit (PETU).
(1) Aftertreatment #2 .DCU #1 (yellow)
(2) Aftertreatment #2 .DCU #2 (red)
(3) Aftertreatment #1 .DCU #2 (green)
(4) Aftertreatment #1 DCU #1 (blue)
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -5 code is active or logged.
Proceed to Test Step 2.
Result: A -6 code is active or logged.
Proceed to Test Step 3.
2. Check the Diesel Exhaust Fluid Control Unit (DCU) Wiring for an Open Circuit
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be off for 2 minutes to allow the DEF pump to purge, to reset the code, and to reset the DCU.
B. Disconnect the 70-pin J1 and 70-pin J2 connector from the SCR Electronic Control Module (ECM).
C. Disconnect the 53-pin connector from the affected DCU.
D. Connect the 398-5063 Probe to the DCU connector.
The probe must be used to prevent damage to the DCU connector.
E. Measure the resistance between the following pins on the affected DCU wiring harness connector:
- For Aftertreatment #1 DCU #1 measure between pin 10 on the 70-pin SCR System ECM J1 connector and pin 52 on


Parts companion Volvo Penta:

806256
Companion flange
806256 Companion flange
AQ115A; AQ115B; AQ130, MD11; MD11C; MD11D, MD1B; MD2B; AQD2B
802723
 
802723 Companion flange
AQ115A; AQ115B; AQ130, MB10A, MD11; MD11C; MD11D, MD1B; MD2B; AQD2B, MD5A; MD5B; MD5C, MD6; MD6A; MD6B
897555
 
897555 Companion flange
AQ115A; AQ115B; AQ130, MD1B; MD2B; AQD2B
809951
 
809951 Companion flange
AQ115A; AQ115B; AQ130, MD1B; MD2B; AQD2B
829277
 
829277 Companion flange
AQ115A; AQ115B; AQ130, MD21B; AQD21B
826826
 
826826 Companion flange
AQ115A; AQ115B; AQ130
813935
 
813935 Companion flange
AQ115A; AQ115B; AQ130