241000 Volvo.Penta Connecting kit


241000 Connecting kit Volvo.Penta D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, D42A; D42A PP, D70B; D70B PP; D70B K, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAMD60A; TAMD60B, TD100CHC; TD100CRC; T Connecting
241000 Connecting kit Volvo Penta
Rating:
78

Buy Connecting kit 241000 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$15.99
 

28-01-2024
0.2006[0.09] pounds
CN: XZGM
24.8V Cordless Vacuum Charger Replacement for Shark Rocket Pro DK33-248080H-U IX141 IX140 IZ140 IZ142 IX142 Z162H IX160 IZ160 IZ163H IZ362H IZ363H IZ140C UZ145 IZ141C IZ162HC XBCHGX140 XSBT620 Series
XZGm ใ€๐…๐จ๐ซ ๐’๐ก๐š๐ซ๐ค ๐‘๐จ๐œ๐ค๐ž๐ญ ๐•๐š๐œ๐ฎ๐ฎ๐ฆ ๐‚๐ก๐š๐ซ๐ ๐ž๐ซ ๐ฌ๐ฉ๐ž๐œ๐ข๐Ÿ๐ข๐œ๐š๐ญ๐ข๐จ๐ง๐ฌใ€‘ Input: AC 100V-240V 50/60Hz; Output: DC 24.8V 800mA; Shark Rocket Pro vacuum charger cord with 6.5FT/2M total is sufficient for indoor use. Strain-eliminated tail cards for greater usability and resistance to flexing. || ใ€๐‘๐ž๐ฉ๐ฅ๐š๐œ๐ž๐ฆ๐ž๐ง๐ญ ๐’๐ก๐š๐ซ๐ค ๐‘๐จ๐œ๐ค๐ž๐ญ ๐•๐š๐œ๐ฎ๐ฎ๐ฆ ๐‚๐ก๐š๐ซ๐ ๐ž๐ซใ€‘Charger for Shark Model DK33-248080H-U Shark Rocket IX160 Series IZ160 Series Cordless Vacuum Stick Vac; Shark IZ162H 26 Rocket Vacumm Cleaner/Aspirateur DONG SONG Charger Shark Rocket Pet Pro Cordless Stick Hand Vacuum IZ162H IZ163H IZ140 IZ140C IZ142 UZ145 WZ140; Shark UZ365H IZ362H IZ363HT Anti-Allergen Cordless Stick Vacuum; Shark Rocket Cordless Stick Vacuum IX140; Shark IX141 Pet Cordless Stick Vacuum || ใ€๐’๐š๐Ÿ๐ž๐ญ๐ฒ ๐š๐ง๐ ๐๐ž๐ซ๐Ÿ๐จ๐ซ๐ฆ๐š๐ง๐œ๐žใ€‘ Certified by FCC, CE, RoHS, CCC, Overcurrent protection, overvoltage protection and overload protection, short-circuit protection ensure the stability and smoothness. The products adopt the industry's top materials and processes, flame retardant shell resistant to high temperature of 1382โ„‰, premium-quality components and safe&reliable power cord. Gives a safe charging. || ใ€๐ˆ๐ฆ๐ฉ๐จ๐ซ๐ญ๐š๐ง๐ญ ๐๐จ๐ญ๐žใ€‘ This charger is a barrel plug, will NOT work with vacuum cleaners that require 2 prong plug charger!!! Please check your product model and interface type to ensure that it is consistent with the description of this charger before purchasing. || ใ€๐€๐Ÿ๐ญ๐ž๐ซ-๐ฌ๐š๐ฅ๐ž๐ฌ ๐ฌ๐ž๐ซ๐ฏ๐ข๐œ๐žใ€‘ Buy with confidence ,If you have any questions about your order and the product, please feel free to contact us. Fast and good service is our pursuit. We hope to bring you a shopping experience.
$194.97
 

28-01-2024

US: Fast 404
S.6068 PTO Yoke Quick Release U/J Size: 35 x 106.5mm Size: 1 3/8-6 Spline 241000 24.10.00
MAXCBD Part Number: 241000 24.10.00
$26.40
 

05-12-2023

LU: Amazon Global Store
MAPCO V-Ribbed Belts (241000)
Mapco Length [mm]: 1000 || Number of Ribs: 4 || Quality Product
Number on catalog scheme: 26
 

Volvo Penta entire parts catalog list:

D100A; D100AK; D100B; TD100A; TD100AG; TD100AK
D100BHC; D100BRC; TD100AHC; TD100ARC
D120A; D120AK; TD120A; TD120AG; TD120AG PP; TD120AK
D42A; D42A PP
D70B; D70B PP; D70B K; TD70B
MD100A; TMD100A; TMD100AK; TMD100A-CC; MD100B; MD100BK; MD100B-CC
MD120A; MD120AK; TMD120A; TMD120AK; TAMD120A; TAMD120AK; TMD120B; TAMD120B; TAMD120B-CC
MD70B; MD70BK; TMD70B; THAMD70B; TAMD70B; AQD70BL; AQD70B
MD70C; TMD70C; TAMD70C; THAMD70C; AQD70BL; AQD70CL
TAMD60A; TAMD60B
TD100CHC; TD100CRC; TD121CHC; TD121CRC; TAD121CHC
TD100G; TD100G-85; TD100G-87; TD100GG; TD100GG-85; TD100GG-87; TD100GGP-87; TD100HP-87; TD100HPB-87; TD100GP; TD100GP-85; TD100GGP; TID100K;
TD120AHC; TD120ARC; TAD120AHC; TD120BHC; TD120BRC; TAD120BHC; TAD120CHC; TD120AHC/CC; TD120ARC/CC
TD120C
TID120FPP; TID120FG; TD120G; TD120GG PP; TD120GG

Information:

If the application is equipped with two throttles, the engine will use the second throttle until the fault is repaired.If a second throttle is not installed or if the second throttle has a fault, the following conditions will occur:
The engine will default to limp home mode.
If the engine speed is higher than the speed in limp home mode, the engine will decelerate to limp home mode.
If the engine speed is lower than the speed in limp home mode, the engine speed will remain at the current speed.
The engine will remain at this speed while the diagnostic code remains active.
All inputs from the faulty throttle are ignored by the ECM until the fault is repaired.
All inputs from the repaired throttle will be ignored by the ECM until the keyswitch has been cycled.The IVS may be installed. The IVS is required for mobile applications. The IVS is part of the throttle position sensor. The IVS is CLOSED when the low idle is set.The configuration parameters for the throttle and for the IVS thresholds are programmed into the ECM. Use the electronic service tool in order to display the configuration parameters for the throttle and for the IVS.If the IVS operates outside of the programmed range, then the engine speed may not respond to changes in the throttle position.The electronic service tool may be used for the following:
If necessary, reset the IVS threshold for an existing IVS.
If necessary, view the IVS change point and reset the IVS thresholds when a new throttle assembly is installed.
Illustration 1 g03726319
Schematic diagram for the Idle Validation Switch (IVS) switch circuit
Not all connectors are shown. Refer to the Electrical Schematic for the application.
Illustration 2 g03726324
View of the pin locations on the P1 connector for the IVS circuit
(42) IVS 2
(67) IVS 1
Table 2
Troubleshooting Test Steps Values Results
1. Check for Active Diagnostic Codes
A. Establish communication between the electronic service tool and the ECM. Refer to Troubleshooting, "Electronic Service Tools"
B. Check for active or logged codes.
Diagnostic Trouble Codes
Result: There is an active or logged , 558-2 or 2970-2 diagnostic code.
Proceed to Test Step 2.
2. Check the Operation of the IVS
A. Turn the keyswitch to the OFF position.
B. Connect the electronic service tool to the diagnostic connector.
C. Turn the keyswitch to the ON position.
D. Use the electronic service tool in order to check the current "Throttle Configuration".
E. Select the "SERVICE" option from the drop-down menu of the electronic service tool.
F. Select the "Throttle Configuration" option on the electronic service tool. Select the appropriate "Throttle Configuration" summary from the menu on the left of the screen. The IVS window for the throttle will indicate "YES" if an IVS is installed.
G. Select the "Throttle status" function on the electronic service tool. Select "Status" function and then select "Throttles" function.
H. The throttle is set in the low idle position.
I. Operate the throttle slowly. The IVS status should change from CLOSED (ON) to OPEN (OFF).
Switch state
Result: The IVS state changes from CLOSED (ON) to OPEN (OFF).
Proceed to Test Step 3.
Result: The IVS does not operate
Proceed to Test Step 4.
3. Check the IVS Threshold
A. Connect the electronic service tool to the diagnostic connector.
B. Turn the keyswitch to the ON position.
C. Use the electronic service tool in order to check the current "Throttle Configuration".
D. Select the "SERVICE" option from the drop-down menu of the electronic service tool.
E. Select the "Throttle Configuration" option on the electronic service tool. Select the appropriate "Throttle Configuration" summary from the menu on the left of the screen. The IVS window for the throttle will indicate "YES" if an IVS is installed. Make a note of the "Idle Validation Min OFF Threshold" parameters that are displayed in the "Throttle Configuration" menu of the electronic service tool. Make a note of the "Idle Validation Max ON Threshold" parameters that are displayed in the "Throttle Configuration" menu of the electronic service tool.
F. To select the "Throttle status" function on the electronic service tool, select "Status" function and then select "Throttles" function.
G. The throttle is set in the low idle position.
H. Operate the throttle slowly. The IVS status should change from CLOSED (ON) to OPEN (OFF).
Switch operation
Result: The IVS switch operates within the "Idle Validation Min OFF Threshold" and the "Idle Validation Max ON Threshold" parameters.
The fault appears to be resolved.
Return the engine to service.
Result: The IVS switch cannot operate within the "Idle Validation Min OFF Threshold" and the "Idle Validation Max ON Threshold" parameters
Proceed to Test Step 10.
4. Inspect Electrical Connectors and Wiring
A. Inspect the P1/J1 ECM connector.
B. Inspect the connectors for the throttle position sensors.
C. Perform a 30 N (6.7 lb) pull test on each of the wires in the ECM connector and the connector for the throttle position sensors.
D. Check all of the wiring associated with the throttle position sensors for abrasions and pinch points.
Damaged wire or connector
Result: A damaged wire or damaged connector was not found.
Proceed to Test Step 5.
Result: A damaged wire or damaged connector was found.
Repair: Repair the damaged wire or the damaged connector.
Use the electronic service tool to clear all logged diagnostic codes. Verify that the repair eliminates the fault.
5. Check the Voltage at the IVS Switch
A. Disconnect the IVS harness connector.
B. Turn the keyswitch to the ON position.
C. Use a suitable multimeter to measure the voltage between the IVS terminal on the harness connector and a suitable ground.
D. Turn the keyswitch to the OFF position.
7.9 V to 12.2 V
Result: The voltage is within the expected range.
Proceed to Test Step 6.
Result: The voltage is not within the expected range.
Proceed to Test Step 7.
6. Check that the IVS is Grounded
A. Disconnect the IVS harness connector.
B. Turn the keyswitch to the ON position.
C. Use a suitable multimeter to measure the voltage between the IVS terminal on the harness connector the ground terminal on the harness connector.
D. Turn the keyswitch to the OFF position.
7.9 V to 12.2 V
Result: The voltage is within the expected range.
Proceed to Test Step 9.
Result: The voltage is not within the expected range. The fault is in the ground wire for the suspect IVS.
Repair: Replace the faulty wiring. Refer


Parts connecting Volvo Penta:

843247
 
843247 Connecting pipe
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D
822530
Connecting rod
822530 Connecting rod
D120A; D120AK; TD120A, MD120A; MD120AK; TMD120A, TD120AHC; TD120ARC; TAD120AHC, TD120C, TID120FPP; TID120FG; TD120G
875687
 
875687 Connecting kit, turbo
TAMD60A; TAMD60B, TAMD60C
846731
 
846731 Connecting rod
DH10A; DH10A 285; DH10A 360, TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1030P, TD100CHC; TD100CRC; TD121CHC, TD100G-87; TD1030ME; TWD1030ME, TD100G-87; TD1030VE; TAD1030V, TD100G; TD100G-85; TD100G-87, TMD100C, TMD102A; TAMD102A
842523
 
842523 Connecting pipe
D120A; D120AK; TD120A, TD120C
7742020_060
847537
 
847537 Connecting pipe
TAD1030G; TD1010G; TWD1010G, TD100G-87; TD1030ME; TWD1030ME, TD100G-87; TD1030VE; TAD1030V, TD100G; TD100G-85; TD100G-87
1696115
 
1696115 Connecting rod
TD100G; TD100G-85; TD100G-87, TD60D; TD60D-83; TD60DPP-83, TD70G; TD70G-83; TD70GPP
Back to top