3826949 Connecting pipe Volvo.Penta
TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P
Connecting
Price: query
Rating:
Compatible models:
Volvo Penta entire parts catalog list:
- Water Pump, Water Filter and Thermostat » 3826949
TAMD165A; TAMD165C; TAMD165P; TAMD165A-A; TAMD165C-A; TAMD165P-A
Information:
2. Disconnect hose assemblies (2), (3) and (4) from the adapter.3. Loosen the hose clamps that hold hose (1) in position. Move the hose away from the radiator and onto the water pump elbow. 4. Disconnect hose assembly (5) from adapter (8).5. Loosen the hose clamps that hold hose (6). Move the hose away from the radiator and onto tube assembly (7). 6. Remove the bolts and straps (9) that hold the bottom of the radiator to the frame. 7. Disconnect hose assembly (12) from the elbow.8. Loosen the clamps that hold hoses (10) and (13). Move the hoses away from the radiator.9. Remove the bolts that hold fan guard (11) to the radiator. Move the fan guard away from the radiator. 10. Remove bolts and washers (15) that hold clips and hose (14) to the lower left corner of the radiator.
Always wear goggles when working on air conditioning systems. The system is under pressure at all times, engine running or not. Escaping Freon-12 (C C12F2 Dichloro Difluoro Methane) can cause freezing of human flesh.Do not smoke while working on air conditioning systems. Inhaling Freon-12 through any smoking material, although not toxic or flammable, can generate phosgene gas and cause violent illness. Also, heat must never be applied to a charged system. See Air Conditioning And Heating Service Manual, Form No. SENR3334, for more information on removal and installation of lines and refrigerant from the system.
11. Release the refrigerant from the air conditioning system. See the topic, Purging The System in Air Conditioning And Heating Service Manual, Form No. SENR3334.12. Disconnect hose assemblies (14) and (17) from air conditioning condensor (16). Put plugs or caps on all of the openings.13. Remove the bolts that hold the clips and hose assemblies (14) and (17) to front of the radiator. Move the hose assemblies away from the front of the radiator. 14. Fasten a hoist to radiator (18). 15. Remove two bolts (19) from each side of the radiator, and remove the radiator from the machine. The weight of the radiator is 762 kg (1683 lb). The following steps are for installation of the radiator.16. Fasten a hoist to radiator (18). Put the radiator in position, and install two bolts (19) on each side of the radiator.17. Fasten the bottom of the radiator to the frame with straps (9) and bolts.18. Connect hose assemblies (14) and (17) to air conditioning condenser (16). Put the hose assemblies and clips in position, and install the bolts that hold them to the radiator.19. Install fan guard (11) on the radiator.20. Put hoses (10) and (13) in position and tighten the hose clamps.21. Connect hose assembly (12).22. Put hose (6) in position and tighten the hose clamps. Connect hose assembly (5) to adapter (8).23. Put hose (1) in position and tighten the hose clamps. Connect hose assemblies (2), (3) and (4) to the adapter.24. Fill the cooling system with coolant to the correct level. See the Maintenance Guide.
Always wear goggles when working on air conditioning systems. The system is under pressure at all times, engine running or not. Escaping Freon-12 (C C12 F2 Dichloro Difluoro Methane) can cause freezing of human flesh.Do not smoke while working on air conditioning systems. Inhaling Freon-12 through any smoking material, although not toxic or flammable, can generate phosgene gas and cause violent illness. Also, heat must never be applied to a charged system. See Air Conditioning And Heating Service Manual, Form No. SENR3334, for more information on removal and installation of lines and refrigerant from the system.
25. Evacuate and charge the air conditioning system. See procedures for evacuating and charging in the Air Conditioning And Heating Service Manual, Form No. SENR3334.End By:a. install radiator guard
Always wear goggles when working on air conditioning systems. The system is under pressure at all times, engine running or not. Escaping Freon-12 (C C12F2 Dichloro Difluoro Methane) can cause freezing of human flesh.Do not smoke while working on air conditioning systems. Inhaling Freon-12 through any smoking material, although not toxic or flammable, can generate phosgene gas and cause violent illness. Also, heat must never be applied to a charged system. See Air Conditioning And Heating Service Manual, Form No. SENR3334, for more information on removal and installation of lines and refrigerant from the system.
11. Release the refrigerant from the air conditioning system. See the topic, Purging The System in Air Conditioning And Heating Service Manual, Form No. SENR3334.12. Disconnect hose assemblies (14) and (17) from air conditioning condensor (16). Put plugs or caps on all of the openings.13. Remove the bolts that hold the clips and hose assemblies (14) and (17) to front of the radiator. Move the hose assemblies away from the front of the radiator. 14. Fasten a hoist to radiator (18). 15. Remove two bolts (19) from each side of the radiator, and remove the radiator from the machine. The weight of the radiator is 762 kg (1683 lb). The following steps are for installation of the radiator.16. Fasten a hoist to radiator (18). Put the radiator in position, and install two bolts (19) on each side of the radiator.17. Fasten the bottom of the radiator to the frame with straps (9) and bolts.18. Connect hose assemblies (14) and (17) to air conditioning condenser (16). Put the hose assemblies and clips in position, and install the bolts that hold them to the radiator.19. Install fan guard (11) on the radiator.20. Put hoses (10) and (13) in position and tighten the hose clamps.21. Connect hose assembly (12).22. Put hose (6) in position and tighten the hose clamps. Connect hose assembly (5) to adapter (8).23. Put hose (1) in position and tighten the hose clamps. Connect hose assemblies (2), (3) and (4) to the adapter.24. Fill the cooling system with coolant to the correct level. See the Maintenance Guide.
Always wear goggles when working on air conditioning systems. The system is under pressure at all times, engine running or not. Escaping Freon-12 (C C12 F2 Dichloro Difluoro Methane) can cause freezing of human flesh.Do not smoke while working on air conditioning systems. Inhaling Freon-12 through any smoking material, although not toxic or flammable, can generate phosgene gas and cause violent illness. Also, heat must never be applied to a charged system. See Air Conditioning And Heating Service Manual, Form No. SENR3334, for more information on removal and installation of lines and refrigerant from the system.
25. Evacuate and charge the air conditioning system. See procedures for evacuating and charging in the Air Conditioning And Heating Service Manual, Form No. SENR3334.End By:a. install radiator guard
Parts connecting Volvo Penta:
842853
842853 Connecting pipe
MD120A; MD120AK; TMD120A, TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P, TD100CHC; TD100CRC; TD121CHC, TD120AHC; TD120ARC; TAD120AHC, TMD121C; TAMD121C; TAMD121D
866631
863794
863794 Connecting rod
TAD1630P; TWD1630P; TWD1630PP, TAMD162A; TAMD162B; TAMD162C, TID162AG; TID162AGP; TID162AP, TWD1620G; TWD1630G; TAD1630G
3835927
3835927 Connecting pipe
TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P
866131
866131 Connecting pipe
TAD1630P; TWD1630P; TWD1630PP, TAD1630V; TWD1630V, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P, TD164KAE, TWD1620G; TWD1630G; TAD1630G
862346
849248
3825072
3825072 Connecting pipe, intercooler
TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P