845218 Connecting pipe Volvo.Penta
TD100G; TD100G-85; TD100G-87, TD120HP-86; TD121; TD121G, TWD1230ME
Connecting
Price: query
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$78.98
08-04-2024
0.5[0.23] Pounds
US: Lift Supports Depot
Lift Supports Depot Qty (2) Horse Trailer Lift Supports Prestige HB Replaces 7807RV 845218 Must Match Part Number
Lift Supports Depot This listing includes 2 automotive Lift Supports For the Trailer Tailgate || Extended Length from Center Mount to Center Mount is 23.9 in. || Compatible with the following OEM Numbers: 7807RV, 845218, Brenderup, PM3743 || These lift supports install easily in minutes with no special tools required. || Lift Supports Depot supports are High Quality Lift Struts. Designed to install easily in minutes, often times without special tools
Lift Supports Depot This listing includes 2 automotive Lift Supports For the Trailer Tailgate || Extended Length from Center Mount to Center Mount is 23.9 in. || Compatible with the following OEM Numbers: 7807RV, 845218, Brenderup, PM3743 || These lift supports install easily in minutes with no special tools required. || Lift Supports Depot supports are High Quality Lift Struts. Designed to install easily in minutes, often times without special tools
Compatible models:
Volvo Penta entire parts catalog list:
- Air Filter and Installation Components: A » 845218
- Air Filter and Installation Components: B
- Air Filter and Installation Components: C
- Air Filter and Installation Components: TD100HPB87
- Air Filter and Installation Components
- Air Filter and Installation Components
TWD1230ME
Information:
Start By:
Remove the hood. Refer to Disassembly and Assembly, "Hood - Remove and Install". The information is in this manual.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Put identification marks on all lines, hoses, wires, and tubes for installation purposes. Plug all lines, hoses, and tubes. This helps to prevent fluid loss and this helps to prevent contaminants from entering the oil system.
Reclaim the refrigerant from the air conditioning system.
Illustration 1 g00292376
Remove wire assembly (1) from the wire clip. Disconnect the quick connections on wire assemblies (1) and (2) .
Illustration 2 g00292378
Disconnect hydraulic hoses (4) and (5) from refrigerant compressor (3) . Remove the O-ring seals from hydraulic hoses (4) and (5) .
Illustration 3 g00292379
This is a view of the refrigerant compressor from a point that is below the machine.
Loosen bolt (6) from refrigerant compressor (3) and the mounting bracket.
Illustration 4 g00292377
Remove bolt (8) from refrigerant compressor (3) and mounting bracket (7) .
Tilt refrigerant compressor (3) toward the engine. Remove V-belt (9) from pulley (10) .
Illustration 5 g00292380
Remove bolt (6) from refrigerant compressor (3) and the mounting bracket. Remove refrigerant compressor (3) from the engine.Installation Procedure
Illustration 6 g00292380
Install refrigerant compressor (3) to the engine. Install bolt (6) to refrigerant compressor (3) and the mounting bracket. Do not tighten bolt (6) at this time.
Illustration 7 g00292377
Tilt refrigerant compressor (3) toward the engine. Install V-belt (9) to pulley (10) .
Install bolt (8) in mounting bracket (7) and refrigerant compressor (3) . Do not tighten bolt (8) at this time.
Adjust the tension of V-belt (9) . Refer to the Operation and Maintenance Manual, SEBU6447, "Fan, Alternator and Water Pump Belts - Inspect-Adjust-Replace" for the proper procedures.
Tighten bolts (6) and (8) .
Illustration 8 g00292378
Check the O-ring seals that were in the hose assemblies that were disconnected. If the O-ring seals are worn or damaged, use new parts for replacement. Connect hydraulic hoses (4) and (5) to refrigerant compressor (3) .
Illustration 9 g00292376
Connect the quick connections on wire assemblies (1) and (2) . Install wire assembly (1) in the wire clip.
Remove the hood. Refer to Disassembly and Assembly, "Hood - Remove and Install". The information is in this manual.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Put identification marks on all lines, hoses, wires, and tubes for installation purposes. Plug all lines, hoses, and tubes. This helps to prevent fluid loss and this helps to prevent contaminants from entering the oil system.
Reclaim the refrigerant from the air conditioning system.
Illustration 1 g00292376
Remove wire assembly (1) from the wire clip. Disconnect the quick connections on wire assemblies (1) and (2) .
Illustration 2 g00292378
Disconnect hydraulic hoses (4) and (5) from refrigerant compressor (3) . Remove the O-ring seals from hydraulic hoses (4) and (5) .
Illustration 3 g00292379
This is a view of the refrigerant compressor from a point that is below the machine.
Loosen bolt (6) from refrigerant compressor (3) and the mounting bracket.
Illustration 4 g00292377
Remove bolt (8) from refrigerant compressor (3) and mounting bracket (7) .
Tilt refrigerant compressor (3) toward the engine. Remove V-belt (9) from pulley (10) .
Illustration 5 g00292380
Remove bolt (6) from refrigerant compressor (3) and the mounting bracket. Remove refrigerant compressor (3) from the engine.Installation Procedure
Illustration 6 g00292380
Install refrigerant compressor (3) to the engine. Install bolt (6) to refrigerant compressor (3) and the mounting bracket. Do not tighten bolt (6) at this time.
Illustration 7 g00292377
Tilt refrigerant compressor (3) toward the engine. Install V-belt (9) to pulley (10) .
Install bolt (8) in mounting bracket (7) and refrigerant compressor (3) . Do not tighten bolt (8) at this time.
Adjust the tension of V-belt (9) . Refer to the Operation and Maintenance Manual, SEBU6447, "Fan, Alternator and Water Pump Belts - Inspect-Adjust-Replace" for the proper procedures.
Tighten bolts (6) and (8) .
Illustration 8 g00292378
Check the O-ring seals that were in the hose assemblies that were disconnected. If the O-ring seals are worn or damaged, use new parts for replacement. Connect hydraulic hoses (4) and (5) to refrigerant compressor (3) .
Illustration 9 g00292376
Connect the quick connections on wire assemblies (1) and (2) . Install wire assembly (1) in the wire clip.
Parts connecting Volvo Penta:
843247
843247 Connecting pipe
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D
241149
241149 Connecting kit
AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, D42A; D42A PP, D70B; D70B PP; D70B K, D70CHC; D70CRC; TD70CHC, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B, MD70C; TMD70
241000
241000 Connecting kit
D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, D42A; D42A PP, D70B; D70B PP; D70B K, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAMD60A; TAMD60B, TD100CHC; TD100CRC; T
846864
846864 Connecting rod
TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TAMD122A; TMD122A; TAMD122P-A, TD100CHC; TD100CRC; TD121CHC, TD120HP-86; TD121; TD121G, TD120HPP; TID120HPP, TD121G-87; TWD1210V; TWD1211V, TID121FG, TMD121C; TAMD121C; TAMD121D, TWD1230ME
847260
847260 Connecting pipe
TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TD120HP-86; TD121; TD121G, TD120HPP; TID120HPP, TD121G-87; TWD1210V; TWD1211V, TWD1230ME
4778371
4778371 Connecting pipe
TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TD120HP-86; TD121; TD121G, TD121G-87; TWD1210V; TWD1211V, TWD1230ME
847449
847449 Connecting pipe
TAD1230P; TD121GP-87; TWD1210P, TD120HP-86; TD121; TD121G, TD120HPP; TID120HPP, TID121FG, TWD1230ME
3090386
3090386 Connecting rod
TAD1230P; TD121GP-87; TWD1210P, TD100G-87; TD1030ME; TWD1030ME, TD100G-87; TD1030VE; TAD1030V, TD121G-87; TWD1210V; TWD1211V, TD610M; TD630ME; TWD630ME, TD610V; TWD610V; TD630VE, TD61A; TD61AW; TD61ACE, TD71A; TID71A; TWD710V, TWD1230ME, TWD610P; TWD