873792 Contact unit Volvo.Penta
TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1030P, TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TAD1240GE; TAD1241GE; TAD1242GE, TAD1630P; TWD1630P; TWD1630PP, TAD1630V; TWD1630V, TAD940VE; TAD941VE; TAD942VE, TD1
Contact
Price: query
Rating:
Compatible models:
TAD1030G; TD1010G; TWD1010G
TAD1030GE; TAD1031GE; TAD1032GE
TAD1030P
TAD1230G; TD1210G; TWD1210G
TAD1230P; TD121GP-87; TWD1210P
TAD1240GE; TAD1241GE; TAD1242GE
TAD1630P; TWD1630P; TWD1630PP
TAD1630V; TWD1630V
TAD940VE; TAD941VE; TAD942VE
TD100G-87; TD1030ME; TWD1030ME
TD121G-87; TWD1210V; TWD1211V
TD610G; TWD610G; TD710G
TD610M; TD630ME; TWD630ME
TID162AG; TID162AGP; TID162AP
TWD1230ME
TWD1240VE; TAD1241VE; TAD1242VE
TWD1620G; TWD1630G; TAD1630G
TWD610P; TWD610PB; TWD710P
Volvo.Penta
Volvo Penta entire parts catalog list:
- Instrument Panel and Alarm Separator Kit, Earlier Production » 873792
- Instrument Panel and Alarm Separator Kit, Later Production
- Instrument Panel and Alarm Separator Kit, Earlier Production
- Instrument Panel and Alarm Separator Kit, Later Production
- Instrument Panel and Alarm Separator Kit, Earlier Production
- Instrument Panel and Alarm Separator Kit, Later Production
- Instrument Panel and Alarm Separator Kit, Earlier Production
- Instrument Panel and Alarm Separator Kit, Later Production
- Instrument Panel and Alarm Separator Kit, Earlier Production
- Instrument Panel and Alarm Separator Kit, Later Production
TAD1630P; TWD1630P; TWD1630PP; TAD1630PB
TAD1630V; TWD1630V
TAD940VE; TAD941VE; TAD942VE; TAD943VE; TAD950VE; TAD951VE; TAD952VE
TD100G-87; TD1030ME; TWD1030ME
- Instrument Panel and Alarm Separator Kit, Later Production
- Instrument Panel and Alarm Separator Kit, Earlier Production
TD610G; TWD610G; TD710G; TWD710G; TAD730G; TWD740GE; TAD740GE; TAD741GE
- Instrument Panel and Alarm Separator Kit, Later Production
- Instrument Panel and Alarm Separator Kit, Earlier Production
- Instrument Panel and Alarm Separator Kit, Later Production
- Instrument Panel and Alarm Separator Kit, Earlier Production
TWD1230ME
- Instrument Panel and Alarm Separator Kit, Earlier Production
- Instrument Panel and Alarm Separator Kit, Later Production
TWD1620G; TWD1630G; TAD1630G; TAD1630GE; TAD1631G; TAD1631GE
- Instrument Panel and Alarm Separator Kit, Earlier Production
- Instrument Panel and Alarm Separator Kit, Later Production
Information:
Table 1
J1939 Code and Description CDL Code and Description Comments
4335-17
Aftertreatment #1 SCR Dosing Air Assist Absolute Pressure : Low - least severe (1) E964 (1)
Low Aftertreatment #1 SCR Dosing Atomization Air Assist Pressure The air pressure is below the trip point for the programmed delay time.
Dosing is disabled until the pressure is correct.
The code is logged.
4335-18
Aftertreatment #1 SCR Dosing Air Assist Absolute Pressure : Low - moderate severity (2) E964 (2)
Low Aftertreatment #1 SCR Dosing Atomization Air Assist Pressure The air pressure is below the trip point for the programmed delay time.
Dosing is disabled until the pressure is correct.
The code is logged.
Table 2
Associated Codes
J1939 Code CDL Code Troubleshooting Procedure
4335-3 3092-3 Troubleshooting, "Sensor Signal (Analog, Active) - Test"
4335-4 3092-4 Troubleshooting, "Sensor Signal (Analog, Active) - Test"
4336-5 3094-5 Troubleshooting, "Solenoid Valve - Test"
4336-6 3094-6 Troubleshooting, "Solenoid Valve - Test" Probable Causes
Codes
Leaks
Air pressure
SensorRecommended Actions
Table 3
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Turn the DC breaker, located in the power distribution box to ON.
B. Connect Cat® Electronic Technician (Cat ET) Service Tool to the service tool connector.
C. Look for active codes that are associated with the system for the event code.
Codes
Result: An associated code is active.
Repair: Troubleshoot any associated codes before continuing with this test.
Result: A code is active or logged.
Proceed to Test Step 2.
2. Check for Air Leaks
A. Turn the DC breaker, located in the power distribution box to OFF.
B. Inspect the air supply lines to the dosing cabinet and inside the dosing cabinet for leaks.
Leaks
Result: An air leak was found.
Repair: Repair the air leak.
Proceed to Test Step 5.
Result: An air leak was not found.
Proceed to Test Step 3.
3. Check the Air Supply to the Dosing Cabinet
A. Turn the DC breaker, located in the power distribution box to OFF.
B. Disconnect the air supply line to the dosing cabinet.
C. Install a pressure gauge on the air supply line to the dosing cabinet.
D. Monitor the air supply pressure from the air compressor.
E. Reconnect the air supply line to the dosing cabinet.
483 kPa to 1068 kPa (70 psi to 155 psi)
Result: The air supply pressure from the air compressor is 483 kPa to 1068 kPa (70 psi to 155 psi).
Proceed to Test Step 4.
Result: The air supply pressure from the air compressor is less than 483 kPa (70 psi). There is a problem with the air supply to the dosing cabinet.
Repair: For information on the air compressor, refer to the Original Equipment Manufacturers (OEM) service information.
If the problem is not resolved, proceed to Test Step 4.
4. Check the Aftertreatment #1 Supply Air Pressure Sensor
A. Turn the DC breaker, located in the power distribution box to ON.
B. Connect Cat ET.
C. Use Cat ET to monitor the following pressures:
- "Aftertreatment #1 Supply Air Pressure"
- "Aftertreatment #1 DEF Dosing Pressure"
Sensor
Result: The pressure sensors are within 20 kPa (3 psi) of each other.
Proceed to Test Step 5.
Result: The pressure sensors are not within 20 kPa (3 psi) of each other.
Repair: Replace the "Aftertreatment #1 Supply Air Pressure" sensor.
If the problem is not resolved, proceed to Test Step 5.
5. Check the Air Assist Valve
A. Turn the DC breaker, located in the power distribution box, to ON.
B. Connect Cat ET.
C. Use Cat ET to perform the following override:
- Set the "Aftertreatment #1 SCR Dosing Air Assist Valve Command Override" to ON .
D. Use Cat ET to monitor the following pressure:
- "Aftertreatment #1 Supply Air Pressure"
414 kPa to 469 kPa (60 psi to 68 psi)
Result: The acceptable range of the air pressure is 414 kPa to 469 kPa (60 psi to 68 psi).
The system is working properly. Return to service.
Result: The air pressure is less than 414 kPa (60 psi).
Proceed to Test Step 6.
6. Check the Dosing Cabinet Air Inlet Strainer for Debris
Debris
Result: The air inlet strainer was clogged with debris.
Repair: Clean the air inlet strainer.
Result: The air inlet strainer was not clogged with debris.
Repair: Ensure that the air pressure regulator is adjusted within the specifications. Refer to Testing and Adjusting , Air Pressure Regulator - Test and Adjust for the appropriate procedure.
If the problem persists after verifying the air pressure regulator setting, proceed to Test Step 7.
7. Check the DEF Injector Tip for the DEF Nozzle
A. Remove the DEF Lance from the Clean Emissions Module (CEM).
B. Inspect the DEF injector nozzle for proper installation and torque. Refer to Specifications , Nozzle (DEF) for proper torque of the DEF injector nozzle.
DEF Injector Tip
Result: The DEF injector tip was properly installed and torqued to specifications.
Repair: Adjust the air pressure regulator on the air manifold to the proper pressure. Refer to Testing and Adjusting , Air Pressure Regulator - Test and Adjust. If the regulator will not adjust, replace the component.
Result: The DEF injector tip was missing and/or not installed properly.
Repair: Replace the DEF injector tip and torque to specifications.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Parts contact Volvo Penta:
846580
846580 Contact
TAD1030GE; TAD1031GE; TAD1032GE, TAD1230G; TD1210G; TWD1210G, TAMD103A, TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P, TD100CHC; TD100CRC; TD121CHC, TD100G; TD100G-85; TD
3817575
3817575 Contact unit
D11B3-A MP; D11B4-A MP, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-J MP; D13B-M MP, D13C1-A MP; D13C2-A MP; D13C3-A MP, D16C-D MH, D5A-T; D5A-TA; D5A-B TA, D9A2A;
3817574
3817574 Contact unit
D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D5A-T; D5A-TA; D5A-B TA, D9A2A; D9A2A D9-425; D9A2A D9-500, TAD1240GE; TAD1241GE; TAD1242GE, TAD1630P; TWD1630P; TWD1630PP, TAD1630V; TWD1630V, TAMD162
1618737
1618737 Contact
1372, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D3-110I-A; D3-110I-B; D3-110I-C, D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H, D8
9148135
9148135 Contact
1372, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D3-110I-A; D3-110I-B; D3-110I-C, D3-110I-D; D3-110I-E; D3-110I-F, D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H, D8
822859
822859 Contact
D100A; D100AK; D100B, D120A; D120AK; TD120A, D42A; D42A PP, D70B; D70B PP; D70B K, MD100A; TMD100A; TMD100AK, TAD1630V; TWD1630V, TAMD103A, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165C; TAMD165P, TMD102A; TAMD1
873791
873791 Contact unit
TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1030P, TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TAD940VE; TAD941VE; TAD942VE, TD100G-87; TD1030ME; TWD1030ME, TD121G-87; TWD1210V; TWD1211V, TD610G; TWD610G; TD710G,
863115
863115 Contact
TAD1630P; TWD1630P; TWD1630PP, TD100G; TD100G-85; TD100G-87, TD120HP-86; TD121; TD121G, TD61A; TD61AW; TD61ACE, TID162AG; TID162AGP; TID162AP