804361 Control cable Volvo.Penta
AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B
Control
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
AD30A; AQAD30A; MD30A
AQ115A; AQ115B; AQ130
AQ120B; AQ125A; AQ140A
AQ125B
AQ131A; AQ131B; AQ131C
AQ145A; BB145A
AQ145B
AQ151A; AQ151B; AQ151C
AQ171A; AQ171C
AQ175A
AQ190A; AQ240A
AQ200B; AQ225B
AQ200C; AQ200D; AQ225C
AQ200D; AQ200F; 280B
AQ225D; AQ225E; AQ225F
AQ260A; AQ260B; BB260A
AQ271A; AQ271B; AQ271C
AQ290A
AQ311A; AQ311B
AQD70D; TAMD70D; TAMD70E
BB231A; BB261A
MB10A
MB2
MD100A; TMD100A; TMD100AK
MD11; MD11C; MD11D
MD120A; MD120AK; TMD120A
MD1B; MD2B; AQD2B
MD21B; AQD21B
MD40A; TMD40A; TMD40B
MD5A; MD5B; MD5C
MD6; MD6A; MD6B
MD70B; MD70BK; TMD70B
MD70C; TMD70C; TAMD70C
TAMD60A; TAMD60B
TAMD60C
Volvo.Penta
Volvo Penta entire parts catalog list:
- Control Cables » 804361
AQ120B; AQ125A; AQ140A; BB140A
AQ125B
AQ131A; AQ131B; AQ131C; AQ131D
AQ145A; BB145A
AQ145B
AQ151A; AQ151B; AQ151C
AQ171A; AQ171C
AQ175A
AQ190A; AQ240A
AQ200B; AQ225B
AQ200C; AQ200D; AQ225C; AQ225D; AQ255A; AQ255B
AQ200D; AQ200F; 280B; 290A; 290DP
AQ225D; AQ225E; AQ225F; BB225A; BB225AV; BB225B; BB225C; 275; 280B; 290A; 290DP; MS3B; MS3C; MS4A
AQ260A; AQ260B; BB260A; BB260AV; BB260B; BB260C
AQ271A; AQ271B; AQ271C; AQ271D; AQ271LB
AQ290A
AQ311A; AQ311B
AQD70D; TAMD70D; TAMD70E
BB231A; BB261A
MB10A
MB2
MD100A; TMD100A; TMD100AK; TMD100A-CC; MD100B; MD100BK; MD100B-CC
MD11; MD11C; MD11D; MD17; MD17C; MD17D
MD120A; MD120AK; TMD120A; TMD120AK; TAMD120A; TAMD120AK; TMD120B; TAMD120B; TAMD120B-CC
MD1B; MD2B; AQD2B; MD3B
MD21B; AQD21B
MD40A; TMD40A; TMD40B; TMD40C; AQD40A; TAMD40A; TAMD40B; AD40B; AQAD40A; AQAD40B
MD5A; MD5B; MD5C
MD6; MD6A; MD6B; MD7; MD7A; MD7B
MD70B; MD70BK; TMD70B; THAMD70B; TAMD70B; AQD70BL; AQD70B
MD70C; TMD70C; TAMD70C; THAMD70C; AQD70BL; AQD70CL
TAMD60A; TAMD60B
TAMD60C
Information:
Start By:
Connect the steering frame lock. Refer to Disassembly and Assembly, "Steering Frame Lock - Separate and Connect".
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide", for tools and supplies suitable to collect and contain fluids in Caterpillar machines.Dispose of all fluids according to local regulations and mandates.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Put identification on all lines, hoses, wires, and tubes for installation purposes. Use caps and plugs on all lines, hoses, and tubes in order to prevent fluid loss or contamination of the systems.
Open the engine hood. The refrigerant compressor is located on the left side of the machine.
Evacuate the air conditioning system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134A Refrigerant"and Special Publication, NEDG5065, "Air Conditioning Tools". The publications will provide the proper procedure, equipment and tools in order to evacuate the air conditioning system in any Caterpillar machine.
Illustration 1 g00331783
Disconnect electrical connectors (1) .
Remove bolt (2), the washer, and the plate. Disconnect hose assemblies (3) .
Illustration 2 g00331784
Loosen bolts (5) and (6), and move refrigerant compressor (4) toward the engine. Move belt (7) off the refrigerant compressor.
Remove bolts (5) and (6), the washers, and the nuts. Remove refrigerant compressor (4) .Installation Procedure
Illustration 3 g00331784
Install refrigerant compressor (4). Install bolts (5) and (6), the washers, and the nuts. Do not tighten bolts (5) and (6) at this time.
Install belt (7) .
Adjust the tension of belt (7) .Note: Use a belt tension gauge such as a Kent Moore Company BT-33-97, or equivalent, to check the belt tension. The correct tension for a new belt is 534 22 N (120 5 lb). The correct tension for a used belt is 400 44 N (90 10 lb).
Tighten bolts (5) and (6) .
Illustration 4 g00331783
Connect hose assemblies (3). Install bolt (2), the washer, and the plate.
Connect the electrical connectors (1) .Note: Use the following method to charge the air conditioning system. First, collect the refrigerant. Evacuate the system, and charge the system with the correct amount of refrigerant. The correct charge of refrigerant is 2 kg (4.4 lb).
Evacuate the air conditioning system and charge the air conditioning system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134A Refrigerant"and Special Publication, NEDG5065, "Air Conditioning Tools". The publications will provide the proper procedure, equipment and tools in order to charge the air conditioning system in any Caterpillar machine.
Close the engine hood.End By: Separate the steering frame lock. Refer to Disassembly and Assembly, "Steering Frame Lock - Separate and Connect".
Connect the steering frame lock. Refer to Disassembly and Assembly, "Steering Frame Lock - Separate and Connect".
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide", for tools and supplies suitable to collect and contain fluids in Caterpillar machines.Dispose of all fluids according to local regulations and mandates.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Put identification on all lines, hoses, wires, and tubes for installation purposes. Use caps and plugs on all lines, hoses, and tubes in order to prevent fluid loss or contamination of the systems.
Open the engine hood. The refrigerant compressor is located on the left side of the machine.
Evacuate the air conditioning system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134A Refrigerant"and Special Publication, NEDG5065, "Air Conditioning Tools". The publications will provide the proper procedure, equipment and tools in order to evacuate the air conditioning system in any Caterpillar machine.
Illustration 1 g00331783
Disconnect electrical connectors (1) .
Remove bolt (2), the washer, and the plate. Disconnect hose assemblies (3) .
Illustration 2 g00331784
Loosen bolts (5) and (6), and move refrigerant compressor (4) toward the engine. Move belt (7) off the refrigerant compressor.
Remove bolts (5) and (6), the washers, and the nuts. Remove refrigerant compressor (4) .Installation Procedure
Illustration 3 g00331784
Install refrigerant compressor (4). Install bolts (5) and (6), the washers, and the nuts. Do not tighten bolts (5) and (6) at this time.
Install belt (7) .
Adjust the tension of belt (7) .Note: Use a belt tension gauge such as a Kent Moore Company BT-33-97, or equivalent, to check the belt tension. The correct tension for a new belt is 534 22 N (120 5 lb). The correct tension for a used belt is 400 44 N (90 10 lb).
Tighten bolts (5) and (6) .
Illustration 4 g00331783
Connect hose assemblies (3). Install bolt (2), the washer, and the plate.
Connect the electrical connectors (1) .Note: Use the following method to charge the air conditioning system. First, collect the refrigerant. Evacuate the system, and charge the system with the correct amount of refrigerant. The correct charge of refrigerant is 2 kg (4.4 lb).
Evacuate the air conditioning system and charge the air conditioning system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134A Refrigerant"and Special Publication, NEDG5065, "Air Conditioning Tools". The publications will provide the proper procedure, equipment and tools in order to charge the air conditioning system in any Caterpillar machine.
Close the engine hood.End By: Separate the steering frame lock. Refer to Disassembly and Assembly, "Steering Frame Lock - Separate and Connect".
Parts control Volvo Penta:
1140193
1140193 Control cable
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ125B, AQ131A; AQ131B; AQ131C, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C
851740
851740 Control
2001; 2001B; 2001AG, MB10A, MB2, MD11; MD11C; MD11D, MD1B; MD2B; AQD2B, MD21B; AQD21B, MD5A; MD5B; MD5C, MD6; MD6A; MD6B
820258
820258 Control cable
AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B
813907
813907 Control cable
AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ145A; BB145A, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B
844035
825627
825627 Control system
AQD70D; TAMD70D; TAMD70E, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAMD103A, TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD162B; TAMD162C, TAMD162C-C; TAMD163A-A; TAMD163P-A, TAMD165A; TAMD165
953932
953932 Control rod
D100A; D100AK; D100B, D120A; D120AK; TD120A, D70B; D70B PP; D70B K, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B
845025
845025 Control sleeve
D100A; D100AK; D100B, D120A; D120AK; TD120A, D70CHC; D70CRC; TD70CHC, MD120A; MD120AK; TMD120A, TAD1230P; TD121GP-87; TWD1210P, TAMD71A; TAMD72A, TD100CHC; TD100CRC; TD121CHC, TD100G; TD100G-85; TD100G-87, TD120AHC; TD120ARC; TAD120AHC, TD120C, TD120