888081 Control cable Volvo.Penta
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D12D-A MH; D12D-B MH; D12D-C MH, D13B-E MH; D13B-E MH (FE); D13B-N MH, D16C-A MH; D16C-B MH; D16C-C MH, D16
Control
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$22.61
08-06-2020
-: -
Standard Abrasives Surface Conditioning RC Belt 888081, 1/2 in x 12 in VFN, 10 per case
High edge durability and flexibility || Excellent starting point for finishing stainless steel to a #4 finish || Designed for blending, coating removal, finishing, and light deburring || Aluminum Oxide on RC material provides good initial and extended cut rate || Best material for general use and average pressure usage
High edge durability and flexibility || Excellent starting point for finishing stainless steel to a #4 finish || Designed for blending, coating removal, finishing, and light deburring || Aluminum Oxide on RC material provides good initial and extended cut rate || Best material for general use and average pressure usage
Compatible models:
AD31D; AD31D-A; AD31XD
AD31L-A; AD31P-A; AD41L-A
AD41D; D41D; TAMD41D
D1-13; D1-13B; D1-20
D11A-A; D11A-B; D11A-C
D11B1-A MP; D11B2-A MP
D12D-A MH; D12D-B MH; D12D-C MH
D13B-E MH; D13B-E MH (FE); D13B-N MH
D16C-A MH; D16C-B MH; D16C-C MH
D16C-D MH
D2-55; D2-55B; D2-55C
D2-75; D2-75B; D2-75C
D3-110I-A; D3-110I-B; D3-110I-C
D4-180I-B; D4-180I-C; D4-180I-D
D4-180I-F; D4-225A-F; D4-225I-F
D5A-T; D5A-TA; D5A-B TA
D6-280A-A; D6-280A-B; D6-280A-C
D6-300A-F; D6-300D-F; D6-300I-F
D9A2A; D9A2A D9-425; D9A2A D9-500
HS25A; HS25A-B; HS25A-C
KAD32P; TAMD42WJ-A; KAD43P-A
KAD42B; KAMD42B; TAMD42B
KAD42P-A; KAMD42P-A; HS1A
MD2010-C; MD2010-D; MD2020-C
MD2010A; MD2020A; MD2030A
MD2010B; MD2020B; MD2030B
MD22A; MD22A-A; MD22L-A
MD22L; MD22P; MD22L-B
TAMD103A
TAMD122A; TMD122A; TAMD122P-A
TAMD162A; TAMD162B; TAMD162C
TAMD162C-C; TAMD163A-A; TAMD163P-A
TAMD165A; TAMD165C; TAMD165P
TAMD61A; TAMD62A
TAMD63L-A; TAMD63P-A
TAMD71A; TAMD72A
TAMD71B; TAMD73P-A; TAMD73WJ-A
TAMD72P-A; TAMD72WJ-A
TAMD74A; TAMD74A-A; TAMD74A-B
TMD102A; TAMD102A; TAMD102D
TMD121C; TAMD121C; TAMD121D
Volvo.Penta
Volvo Penta entire parts catalog list:
AD31L-A; AD31P-A; AD41L-A; AD41P-A; D41L-A; TAMD31L-A; TAMD31M-A; TAMD31P-A; TAMD31S-A; TAMD41H-A; TAMD41H-B; TAMD41P-A; TAMD41L-A; TAMD41M-A
AD41D; D41D; TAMD41D; TMD41D; HS1A
D1-13; D1-13B; D1-20; D1-20B; D1-30; D1-30B; D2-40; D2-40B; D1-13F; D1-20F; D1-30F; D2-40F
D11A-A; D11A-B; D11A-C; D11A-D MP; D11A-D (IPS); D11A-E; D11A-E MP; D11A-C MP; D11A-C (IPS)
D11B1-A MP; D11B2-A MP
D12D-A MH; D12D-B MH; D12D-C MH; D12D-E MH; D12D-G MH; D12C-A MP; D12D-A MP; D12D-B MP; D12D-C MP; D12D-D MP; D12D-E MP; D12D-F MP; D12D-G M
D13B-E MH; D13B-E MH (FE); D13B-N MH; D13B-N MH (FE)
D16C-A MH; D16C-B MH; D16C-C MH
D16C-D MH
D2-55; D2-55B; D2-55C; D2-55D; D2-55E; D2-55F
D2-75; D2-75B; D2-75C; D2-60F; D2-75F
D3-110I-A; D3-110I-B; D3-110I-C; D3-130A-A; D3-130I-A; D3-130A-B; D3-130I-B; D3-130A-C; D3-130I-C; D3-160A-A; D3-160I-A; D3-160A-B; D3-160I-
D4-180I-B; D4-180I-C; D4-180I-D; D4-180I-E; D4-210A-A; D4-225A-B; D4-210I-A; D4-210I-B; D4-225I-B; D4-225A-C; D4-225A-D; D4-225I-C; D4-225I-
D4-180I-F; D4-225A-F; D4-225I-F; D4-260A-F; D4-260D-F; D4-260I-F; D4-300A-F; D4-300D-F; D4-300I-F
D5A-T; D5A-TA; D5A-B TA; D7A-T; D7A-TA; D7A-B TA; D7C-TA; D7C-B TA
D6-280A-A; D6-280A-B; D6-280A-C; D6-280A-D; D6-280A-E; D6-280I-A; D6-280I-B; D6-280I-C; D6-280I-D; D6-280I-E; D6-310I-A; D6-310A-A; D6-310A-
D6-300A-F; D6-300D-F; D6-300I-F; D6-330A-F; D6-330D-F; D6-330I-F; D6-370A-F; D6-370D-F; D6-370I-F; D6-400A-F; D6-435D-F; D6-435I-F; D6-435I-
D9A2A; D9A2A D9-425; D9A2A D9-500; D9A2A D9-500 (R4); D9A2A D9-575; D9A2B D9-425; D9A2B D9-500 (R5); D9A2B D9-575; D9A2C D9-425; D9A2D D9
HS25A; HS25A-B; HS25A-C; HS25AE-A; HS45A; HS45AE; HS63A-A; HS63AE-A; HS63IV-A; HS63IVE-A; HS63IVE-D; HS80AE; HS80AE-B; HS80VE; HS85AE-A; HS85IV
KAD32P; TAMD42WJ-A; KAD43P-A; KAMD43P; KAMD43P-A; KAMD43P-B; KAD44P; KAD44P-B; KAD44P-C; KAMD44P-A; KAMD44P-C; KAD300-A; KAMD300-A; HS1A; HS1E
KAD42B; KAMD42B; TAMD42B
KAD42P-A; KAMD42P-A; HS1A
MD2010-C; MD2010-D; MD2020-C; MD2020-D; MD2030-C; MD2030-D; MD2040-C; MD2040-D; 120S-D; 120S-E
MD2010A; MD2020A; MD2030A; MD2040A; MS2B-R; MS2A-D; MS2A-E; MS2L-D; MS2L-E; 120S-D; 120S-E; MD2010; MD2030; MD2040; MD2020
MD2010B; MD2020B; MD2030B; MD2040B; MS2L-D; MS2A-D; 120S-D; MS2B-R; MS2A-E; MS2L-E
MD22A; MD22A-A; MD22L-A; TMD22A; TMD22-A; MS2B-A; MS2B-R; MS2A-E; MS2B-L; MS2L-E; 120S-E; MD22; MD22L
MD22L; MD22P; MD22L-B; MD22P-B; TMD22-B; TMD22P-C; TAMD22P-B; HS25A; HS25A-B; 120S-E; MS2A-E; MS2L-E; MS2B-L; TMD22B
TAMD103A
TAMD122A; TMD122A; TAMD122P-A; TAMD122P-B; TAMD122P-C; TMD122A/C; TAMD122AF
TAMD162A; TAMD162B; TAMD162C; TAMD162C-B
TAMD162C-C; TAMD163A-A; TAMD163P-A
TAMD165A; TAMD165C; TAMD165P; TAMD165A-A; TAMD165C-A; TAMD165P-A
TAMD61A; TAMD62A
TAMD63L-A; TAMD63P-A
TAMD71A; TAMD72A
TAMD71B; TAMD73P-A; TAMD73WJ-A
TAMD72P-A; TAMD72WJ-A
TAMD74A; TAMD74A-A; TAMD74A-B; TAMD74C-A; TAMD74C-B; TAMD74L-A; TAMD74L-B; TAMD74P-A; TAMD74P-B; TAMD75P-A
TMD102A; TAMD102A; TAMD102D
TMD121C; TAMD121C; TAMD121D; TAMD122C; TAMD122D
Information:
CO - Crankcase Lubricating Oil
4 - Diesel Engine Crankcase
Use Superior Lubricants (Series 3) Only
Check oil level every 10 service hours when hot with the engine in a level position and running at low idle speed. Oil level should be between the "full" and "add oil" marks on gauge (1). Add oil at (2) when the level drops to the "add oil" mark. Do not overfill.The oil level may be considerably higher than the "full" mark on the gauge if the full capacity of crankcase oil is checked after the engine has been stopped for several minutes.The diesel engine has a guard to protect the gauge from spray so the oil level should be checked with the engine running.See the topic, "Crankcase Lubricating Oil" - Also see Note A. Drain the crankcase while the engine is hot. Remove the plug (3) from the crankcase to drain the oil. After draining clean and replace the plug. For recommended oil change periods see the topic, "Diesel Engine Crankcase Lubricating Oil Change Periods." Also see the topic, "Crankcase Lubricating Oil." See Note A. Every 125 service hours or less, depending on the fuel sulphur content, drain the oil filter housing and replace the element with a new Caterpillar element. Remove the drain plug (4), cover screw, and cover. Remove the element (5) from the housing and install the new element. Clean and install the drain plug and the cover. Run the engine for two minutes, then add oil to bring level to full mark on gauge. After draining crankcase, refill at (6). Start the diesel engine. Run engine for two minutes then add oil to bring level to "full" mark on gauge, while engine is running. Caterpillar Diesel Engines are built in a clean modern diesel engine factory and each crankcase is filled with a good quality of new crankcase oil. For these reasons the initial crankcase oil change period for this engine should be at the usual crankcase oil change period. See the topic, "Crankcase Lubricating Oil Change Periods." Remove the upper breather element at (7) and wash in clean kerosene or diesel fuel each time the crankcase is drained.Every 250 service hours, remove the breather housing (8). Wash the housing and the lower element with clean kerosene or diesel fuel.11 -Transmission System
Use Superior Lubricants (Series 3) Only
Check the oil level in the transmission system every 10 service hours, using the gauge (1). Check when the oil is warm with the engine running at low idle speed, transmission in neutral, safety lock on and engine level. Add oil to the system at (2). Every 1000 service hours, drain the transmission system. To drain the transmission, remove guard (4), then remove transmission drain plug. Also remove sump drain plug (5) and transfer gear case drain plug (6). Clean and install the drain plugs and refill the system to the correct level. When extreme loads and high temperatures are encountered it may be necessary to change oil every 500 service hours. This can be determined by examining the oil on the oil level gauge and if it appears to be extremely thick the oil should be changed.At each oil change period, remove and wash the element in the breather (3). Pour 1/4 pint (0.12 liter) of oil through the element and install it. At each oil change period, remove the screen (7) from the torque divider transmission. Clean and install the screen, using a new gasket if necessary. After the first 50 service hours operation of a new machine or of a reconditioned transmission, and at each oil change period thereafter, clean the range transmission sump screen. Remove the two bolts and the flange (10) from the adapter (8), then remove the screen (9) from the adapter. When the machine is level, only one or two quarts of oil will drain from the adapter and hoses when the flange retaining bolts are removed. Clean and install the screen and the flange. Install a new gasket if necessary.At each oil change period, remove the cover and the screens (11) from the transmission oil sump. Clean and install the screens and the cover, using new gaskets if necessary. Change the element in the transmission oil filter after the first 50 service hours operation of a new machine or of a reconditioned transmission and every 250 service hours thereafter. Remove the drain cover (14) to drain the filter. Remove the filter cover (13) and the element (12). Install a new Caterpillar element and the cover, using a new seal if necessary. Clean and install the drain cover. Operate the machine for a few minutes to fill the filter housing with oil, then check the oil level in the transmission system and refill if necessary.12 Hydraulic Retarder
Use Superior Lubricants (Series 3) Only
Every 125 service hours, check the oil level when the oil is warm and the engine is in a level position. Be sure the control is in the "off" position to eliminate any pressure from the system. Oil should be to the level of the "full hot" mark on the gauge (1). Do not overfill.Every 250 service hours, remove, wash and oil the breather (2). Every 1000 service hours, remove the drain plug (5), the filler cap (4), and the bleeder cap (3) to drain the system. After draining, install the drain plug and refill the system slowly to the proper level, then install the bleeder cap and the filler cap. Recheck the oil level after the retarder has been applied several times and fill if necessary.15 Starter Pinion Housing
Every 125 service hours check the oil level by removing plug (1). Oil should be to the level of the plug opening.Every 1000 service hours drain at (2). Install plug and fill at (1) to level of plug opening.BR - Ball and Roller Bearing Lubricant
1 Water Pump Bearings
Every 250 service hours lubricate the water pump bearings at (1) until grease appears at relief valve (2). Wipe off excess lubricant.2 Belt Adjusting Pulley Bracket
Every 125 service hours lubricate
4 - Diesel Engine Crankcase
Use Superior Lubricants (Series 3) Only
Check oil level every 10 service hours when hot with the engine in a level position and running at low idle speed. Oil level should be between the "full" and "add oil" marks on gauge (1). Add oil at (2) when the level drops to the "add oil" mark. Do not overfill.The oil level may be considerably higher than the "full" mark on the gauge if the full capacity of crankcase oil is checked after the engine has been stopped for several minutes.The diesel engine has a guard to protect the gauge from spray so the oil level should be checked with the engine running.See the topic, "Crankcase Lubricating Oil" - Also see Note A. Drain the crankcase while the engine is hot. Remove the plug (3) from the crankcase to drain the oil. After draining clean and replace the plug. For recommended oil change periods see the topic, "Diesel Engine Crankcase Lubricating Oil Change Periods." Also see the topic, "Crankcase Lubricating Oil." See Note A. Every 125 service hours or less, depending on the fuel sulphur content, drain the oil filter housing and replace the element with a new Caterpillar element. Remove the drain plug (4), cover screw, and cover. Remove the element (5) from the housing and install the new element. Clean and install the drain plug and the cover. Run the engine for two minutes, then add oil to bring level to full mark on gauge. After draining crankcase, refill at (6). Start the diesel engine. Run engine for two minutes then add oil to bring level to "full" mark on gauge, while engine is running. Caterpillar Diesel Engines are built in a clean modern diesel engine factory and each crankcase is filled with a good quality of new crankcase oil. For these reasons the initial crankcase oil change period for this engine should be at the usual crankcase oil change period. See the topic, "Crankcase Lubricating Oil Change Periods." Remove the upper breather element at (7) and wash in clean kerosene or diesel fuel each time the crankcase is drained.Every 250 service hours, remove the breather housing (8). Wash the housing and the lower element with clean kerosene or diesel fuel.11 -Transmission System
Use Superior Lubricants (Series 3) Only
Check the oil level in the transmission system every 10 service hours, using the gauge (1). Check when the oil is warm with the engine running at low idle speed, transmission in neutral, safety lock on and engine level. Add oil to the system at (2). Every 1000 service hours, drain the transmission system. To drain the transmission, remove guard (4), then remove transmission drain plug. Also remove sump drain plug (5) and transfer gear case drain plug (6). Clean and install the drain plugs and refill the system to the correct level. When extreme loads and high temperatures are encountered it may be necessary to change oil every 500 service hours. This can be determined by examining the oil on the oil level gauge and if it appears to be extremely thick the oil should be changed.At each oil change period, remove and wash the element in the breather (3). Pour 1/4 pint (0.12 liter) of oil through the element and install it. At each oil change period, remove the screen (7) from the torque divider transmission. Clean and install the screen, using a new gasket if necessary. After the first 50 service hours operation of a new machine or of a reconditioned transmission, and at each oil change period thereafter, clean the range transmission sump screen. Remove the two bolts and the flange (10) from the adapter (8), then remove the screen (9) from the adapter. When the machine is level, only one or two quarts of oil will drain from the adapter and hoses when the flange retaining bolts are removed. Clean and install the screen and the flange. Install a new gasket if necessary.At each oil change period, remove the cover and the screens (11) from the transmission oil sump. Clean and install the screens and the cover, using new gaskets if necessary. Change the element in the transmission oil filter after the first 50 service hours operation of a new machine or of a reconditioned transmission and every 250 service hours thereafter. Remove the drain cover (14) to drain the filter. Remove the filter cover (13) and the element (12). Install a new Caterpillar element and the cover, using a new seal if necessary. Clean and install the drain cover. Operate the machine for a few minutes to fill the filter housing with oil, then check the oil level in the transmission system and refill if necessary.12 Hydraulic Retarder
Use Superior Lubricants (Series 3) Only
Every 125 service hours, check the oil level when the oil is warm and the engine is in a level position. Be sure the control is in the "off" position to eliminate any pressure from the system. Oil should be to the level of the "full hot" mark on the gauge (1). Do not overfill.Every 250 service hours, remove, wash and oil the breather (2). Every 1000 service hours, remove the drain plug (5), the filler cap (4), and the bleeder cap (3) to drain the system. After draining, install the drain plug and refill the system slowly to the proper level, then install the bleeder cap and the filler cap. Recheck the oil level after the retarder has been applied several times and fill if necessary.15 Starter Pinion Housing
Every 125 service hours check the oil level by removing plug (1). Oil should be to the level of the plug opening.Every 1000 service hours drain at (2). Install plug and fill at (1) to level of plug opening.BR - Ball and Roller Bearing Lubricant
1 Water Pump Bearings
Every 250 service hours lubricate the water pump bearings at (1) until grease appears at relief valve (2). Wipe off excess lubricant.2 Belt Adjusting Pulley Bracket
Every 125 service hours lubricate
Parts control Volvo Penta:
1140186
1140186 Control cable
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ125B, AQ131A; AQ131B; AQ131C, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C
888082
888082 Control cable
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D12D-A MH; D12D-B MH; D12D-C MH, D13B-E MH; D13B-E MH (FE); D13B-N MH, D16C-A MH; D16C-B MH; D16C-C MH, D16
888090
888090 Control cable
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D12D-A MH; D12D-B MH; D12D-C MH, D13B-E MH; D13B-E MH (FE); D13B-N MH, D16C-A MH; D16C-B MH; D16C-C MH, D16
1140115
1140115 Control cable
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D12D-A M
844213
844213 Control wheel
AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD41D; D41D; TAMD41D, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, MD31A; TMD31A; TMD31B, MD31A; TMD31B; TAMD31B, MD40A; TMD40A; TMD40B, TD30A; TD31ACE; TD40A, TMD41A; TMD41B; D41A, TMD41B; D41B; TAM
1140134
1140134 Control cable
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D12D-A MH; D12D-B MH; D12D-C MH, D13B-E MH; D13B-E MH (FE); D13B-N MH, D16C-A MH; D16C-B MH; D16C-C MH, D16
3855650
3855650 Control panel
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, DP-C1; DP-D1; DP-S, DP-E; SP-E; TSK DP-E, DP-G; TSK DP-G, DPX-A; TSK DPX-A, DPX-R; DPX-R 1.47; DPX-R 1.51, DPX-S; DPX-S1; DPX-S 1.59, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P
873226
873226 Control unit
230A; 230B; 250A, 430; 430A; 430B, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, DP-C1; DP-D1; DP-S, DP-E; SP-E; TSK DP-E, DP-G; TSK DP-G, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P-A; HS1A