Table 1
Diagnostic Trouble Codes for the Data Link Configuration Status
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
- 1603-14 Machine Control Module: Special Instruction The data from a machine ECM is not in the correct format.
The code is logged.
639-14 247-14 J1939 Network #1 : Special Instruction The data received from the CAN A data bus is not in the correct format.
The code is logged.
1231-14 2348-14 J1939 Network #2 : Special Instruction The data received from the CAN B data bus is not in the correct format.
The code is logged.
5576-14 3468-14 Aftertreatment #1 Identification : Special Instruction The data received from the aftertreatment ID module is not in the correct format.
The code is logged. The diagnostic code for the special instruction is logged to report the configuration status of the data link. The diagnostic code for the special instruction does not check the physical condition of the data link.The following list identifies possible faults on the data link:
Incorrect personality module code
An invalid configuration parameter
Incorrect module or display on the data link
Damaged data link wiring
Incompatible software in one of the ECMsComplete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Check for an Associated -9 Code
A. Establish communication between the electronic service tool and the Electronic Control Module (ECM) for the engine.
B. Download a "Warranty Report" from the engine ECM before troubleshooting or clearing diagnostic trouble codes.
C. Check for active diagnostic codes.
Associated Trouble code
Result: An associated -9 code is logged.
Repair: Repair all associated -9 codes before continuing with this procedure. Refer to Troubleshooting, "CAN Data Link - Test".
If a -14 code is still present after resolving the -9 code, proceed to Test Step 2.
Result: An associated -9 code is not logged.
Proceed to Test Step 2.
2. Check the Personality Module Code for Compatibility with the Application
A. Connect to the electronic service tool.
B. Select the ECM connection that is related to the logged code.
C. Check if the personality module code is valid for the application.
Compatible personality module
Result: The code is valid for the application.
Proceed to Test Step 3.
Result: The code is not valid for the application.
Repair: Obtain the correct flash file and update the ECM. Reset all active codes and clear all logged codes. Return the unit to service.
3. Check that the Latest Available Software is Installed
A. Ensure that the latest software is installed on the engine ECM.
Ensure that the software installed is for the correct system voltage (12 V or 24 V).
If necessary, refer to Troubleshooting, "ECM Software - Install" for the correct procedure.
Software
Result: The latest software is not installed.
Repair: Install the latest software. If necessary, refer to Troubleshooting, "ECM Software - Install" for the correct procedure.
Turn the keyswitch to the ON position.
If the fault is cleared, return the engine to service.
If the fault is still present, proceed to Test Step 4.
Result: The latest software is installed. The software is for the correct system voltage.
Proceed to Test Step 4.
4. Check the Configuration Parameters
A. Check the configuration parameters to ensure that the parameters are programmed correctly. Refer to Troubleshooting, "Configuration Parameters".
B. Select the ECM connection that is related to the logged code.
Correct configuration parameters
Result: The configuration parameters are programmed correctly.
Proceed to Test Step 5.
Result: The configuration parameters are not programmed correctly.
Repair: Program the parameters to function with the other modules on the data link. Reset all active codes and clear all logged codes. Return the unit to service.
5. Check for Compatibility with Any Other ECM on the Data Link
A. Use the as shipped information found in SIS web TMI to determine if any other ECM or display on the data link are incompatible.
B. Select the ECM connection that is related to the logged code.
Compatible ECM
Result: The ECMs are not compatible.
Repair:Replace the incompatible ECM with the correct module. Reset all active codes and clear all logged codes. Return the unit to service.
If the procedure did not correct the fault, contact the Dealer Solutions Network (DSN).


Parts cross Volvo Penta:

949947
 
949947 Cross recessed screw
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQD70D; TAMD70D; TAMD70E, D1-13; D1-13B; D1-20, D12D-A MH; D12D-B MH;
956094
 
956094 Cross recessed screw
AD30A; AQAD30A; MD30A, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A, AQ200D; AQ200F; 280B, AQ205A; AQ205LB, AQ211A; DP-A; SP-A, AQ225D; AQ225E; AQ225F, AQ231A; AQ231B;
956058
Cross recessed screw
956058 Cross recessed screw
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, D100A; D100AK; D100B, D42A; D42A PP, D70B; D70B PP; D70B K, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120
950046
 
950046 Cross recessed screw
AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ145A; BB145A, AQ175A, AQ190A; AQ240A, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A, AQ290A, AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100B
950013
Cross recessed screw
950013 Cross recessed screw
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A
950024
 
950024 Cross recessed screw
AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, D1-13; D1-13B; D1-20, D100A; D100AK; D100B, D120A; D120AK; TD120A, D2-55; D2-55B; D2-55C, D2-75; D2-75B; D2-75C, D3-110I-A; D3-110I
950021
 
950021 Cross recessed screw
430; 430A; 430B, 500; 500A; 501A, 571A, AD31D; AD31D-A; AD31XD, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ145A; BB145A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D120A; D120AK; TD120A, D42A; D42A P
956169
 
956169 Cross recessed screw
MD40A; TMD40A; TMD40B, TAD1030P, TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TD100G-87; TD1030VE; TAD1030V, TD100G; TD100G-85; TD100G-87, TD120HP-86; TD121; TD121G, TD121G-87; TWD1210V; TWD1211V, TD610V; TWD610V; TD630VE, TD61A; TD61
Back to top