Diagnostic Trouble Codes for DEF Pump Sensor Supply
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
3511-11 3482-11 Sensor Supply #3:Other Failure Mode High or low battery voltage supply has been detected on the 5V supply to the DEF pump.
Follow the troubleshooting procedure in order to identify the root cause of the problem.
Table 2
Required Tools
Tool Part Number Part Description Qty
A 372-5260 Test Kit 1
Illustration 1 g03811023Complete the procedure in the order in which the steps are listed.
Table 3
Troubleshooting Test Steps Values Results
1. Check the DEF Pump Pressure Sensor Supply Circuit for Excessive Voltage
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be OFF for 2 minutes to allow the DEF pump to purge, reset the code, and reset the Diesel Exhaust Fluid Controller (DCU).
B. Disconnect the Pump Electronic Tank Unit (PETU) harness from the DEF pump.
C. Verify that the harness connector is free of debris, free of corrosion, and securely connected.
D. Turn the keyswitch ON.
E. Measure the voltage between the 5V SUPPLY (Terminal 2) at the DEF pump connector and a known good ground source.
Supply voltage
Result: The voltage is greater than 5V.
Proceed to Test Step 3.
Result: The voltage is 5V or less.
Proceed to Test Step 2.
2. Check the DEF Pump Pressure Sensor Supply for a Short Circuit to Ground
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be OFF for 2 minutes to allow the DEF pump to purge, reset the code, and reset the DCU.
B. Disconnect the PETU wiring harness from the DEF pump.
C. Disconnect the 86 pin connector from the DCU.
D. Connect the 398-5056 Break-out Connector to the DEF pump connector.
Note: The 398-5056 Break-out Connector is included in the 372-5260 Test Kit.
Note: The 398-5056 Break-out Connector must be used to prevent damage to the DEF pump connector.
E. Measure the resistance between the 5V SUPPLY (Terminal 2 on the DEF pump connector) and a known good ground source.
Greater than 100k Ohms
Result: There was more than 100K ohms of resistance between the 5V SUPPLY and a ground source.
Proceed to Test Step 4.
Result: There was less than 100K ohms of resistance between the 5V SUPPLY and a ground source. A short circuit to ground has been detected.
Repair: Repair or replace the wiring harness.
Proceed to Test Step 4.
3. Check the DEF Pump Supply for a Pin-to Pin Short Circuit
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be OFF for 2 minutes to allow the DEF pump to purge, reset the code, and reset the DCU.
B. Disconnect the PETU wiring harness from the DEF pump.
C. Disconnect the 86 pin connector from the DCU.
D. Connect the 398-5063 Break-out Connector to the DCU connector.
Note: The 398-5063 Break-out Connector is included in the 372-5260 Test Kit.
Note: The 398-5063 Break-out Connector must be used to prevent damage to the DCU connector.
E. Measure the resistance between the 5V SUPPLY (Terminal 19 at the DCU connector) and all other pins in the DCU 86 pin connector.
Greater than 100k Ohms
Result: There was more than 100K ohms of resistance between the 5V SUPPLY and all other pins in the DEF pump connector.
Proceed to Test Step 4.
Result: There was less than 100K ohms of resistance between the 5V Supply and all other pins in the DEF pump connector. There is a fault in the wiring harness.
Repair: Repair or replace the wiring harness.
Proceed to Test Step 4.
4. Perform a DEF Dosing System Verification Test
A. Turn the keyswitch to the "ON" position. Do not start the engine.
B. Connect the electronic service tool to the diagnostic connector.
C. Perform the "DEF Dosing System Verification Test" .
Diagnostic codes
Result: The code did not return.
Return the unit to service.
Result: The code returned. A failed DEF pump has been detected.
Repair: Replace the DEF pump.
Perform the DEF Dosing Verification Test to verify that the fault has been eliminated.
If the fault is still present, contact the Dealer Solutions Network (DSN).


Parts cylinder Volvo Penta:

859648
Cylinder head
859648 Cylinder head
MD22A; MD22A-A; MD22L-A
3581737
 
3581737 Cylinder head
MD22A; MD22A-A; MD22L-A
3803317
 
3803317 Cylinder head
MD22A; MD22A-A; MD22L-A, MD22L; MD22P; MD22L-B
21122661
 
21122661 Cylinder head
MD22A; MD22A-A; MD22L-A
859647
Cylinder head gasket
859647 Cylinder head gasket
MD22A; MD22A-A; MD22L-A, MD22L; MD22P; MD22L-B
859625
Cylinder block
859625 Cylinder block
MD22A; MD22A-A; MD22L-A, MD22L; MD22P; MD22L-B
3803318
 
3803318 Cylinder head
MD22L; MD22P; MD22L-B
3803319
 
3803319 Cylinder head
MD22L; MD22P; MD22L-B
Back to top