Table 1
J1939 Code and Description CDL Code and Description Comments
7598-5
Aftertreatment #1 DEF Backflow Valve #1 : Current Below Normal 5024-5
Aftertreatment #1 Diesel Exhaust Fluid Backflow Valve #1 : Current Below Normal This code indicates that there is a problem with the aftertreatment #1 DEF backflow valve #1 and/or the electrical circuit for the backflow valve.
7598-6
Aftertreatment #1 DEF Backflow Valve #1 : Current Above Normal 5024-6
Aftertreatment #1 Diesel Exhaust Fluid Backflow Valve #1 : Current Above Normal This code indicates that there is a problem with the aftertreatment #1 DEF backflow valve #1 and/or the electrical circuit for the backflow valve.
7599-5
Aftertreatment #1 DEF Backflow Valve #2 : Current Below Normal 5025-5
Aftertreatment #1 Diesel Exhaust Fluid Backflow Valve #2 : Current Below Normal This code indicates that there is a problem with the aftertreatment #1 DEF backflow valve #2 and/or the electrical circuit for the backflow valve.
7599-6
Aftertreatment #1 DEF Backflow Valve #2 : Current Above Normal 5025-6
Aftertreatment #1 Diesel Exhaust Fluid Backflow Valve #2 : Current Above Normal This code indicates that there is a problem with the aftertreatment #1 DEF backflow valve #2 and/or the electrical circuit for the backflow valve.
7600-5
Aftertreatment #2 DEF Backflow Valve #1 : Current Below Normal 5026-5
Aftertreatment #2 Diesel Exhaust Fluid Backflow Valve #1 : Current Below Normal This code indicates that there is a problem with the aftertreatment #2 DEF backflow valve #1 and/or the electrical circuit for the backflow valve.
7600-6
Aftertreatment #2 DEF Backflow Valve #1 : Current Above Normal 5026-6
Aftertreatment #2 Diesel Exhaust Fluid Backflow Valve #1 : Current Above Normal This code indicates that there is a problem with the aftertreatment #2 DEF backflow valve #1 and/or the electrical circuit for the backflow valve.
7601-5
Aftertreatment #2 DEF Backflow Valve #2 : Current Below Normal 5027-5
Aftertreatment #2 Diesel Exhaust Fluid Backflow Valve #2 : Current Below Normal This code indicates that there is a problem with the aftertreatment #2 DEF backflow valve #2 and/or the electrical circuit for the backflow valve.
7601-6
Aftertreatment #2 DEF Backflow Valve #2 : Current Above Normal 5027-6
Aftertreatment #2 Diesel Exhaust Fluid Backflow Valve #2 : Current Above Normal This code indicates that there is a problem with the aftertreatment #2 DEF backflow valve #2 and/or the electrical circuit for the backflow valve.
Table 2
Required Tools
Part Number Part Name Qty
372-5260 Test Lead Tool Group 1
Illustration 1 g06300650
The DEF pumps are on the front side of the Pump Electronic Tank Unit (PETU).
(1) Coolant diverter valve for Aftertreatment #2 DEF pump #2 system (red)
(2) Aftertreatment #2 DEF pump #2 header (red)
(3) Aftertreatment #2 DEF pump #1 header (yellow)
(4) Coolant diverter valve for Aftertreatment #2 DEF pump #1 system (yellow)
(5) DEF backflow valve for Aftertreatment #2 DEF pump #2 system (red)
(6) DEF backflow valve for Aftertreatment #2 DEF pump #1 system (yellow)
(7) Aftertreatment #2 DEF pump #2 (red)
(8) Aftertreatment #2 DEF pump #1 (yellow)
(9) Aftertreatment #1 DEF pump #2 (green)
(10) Aftertreatment #1 DEF pump #1 (blue)
(11) DEF backflow valve for Aftertreatment #1 DEF pump #2 system (green)
(12) DEF backflow valve for Aftertreatment #1 DEF pump #1 system (blue)
(13) Coolant diverter valve for Aftertreatment #1 DEF pump #2 system (green)
(14) Aftertreatment #1 DEF pump #2 header (green)
(15) Aftertreatment #1 DEF pump #1 header (blue)
(16) Coolant diverter valve for Aftertreatment #1 DEF pump #1 system (blue)
Illustration 2 g06300910
The DEF injectors are on the inlet of the Clean Emissions Module (CEM). There are injectors on both inlets of the dual CEM applications.
(17) Aftertreatment #2 DEF pump #1 DEF injector #2 (yellow)
(18) Aftertreatment #2 DEF pump #2 DEF injector #1 (red)
(19) Aftertreatment #1 DEF pump #1 DEF injector #2 (blue)
(20) Aftertreatment #1 DEF pump #2 DEF injector #1 (green)
Illustration 3 g06300911
The DEF injectors are on the inlet of the CEM. There are injectors on both inlets of the dual CEM applications.
(21) Aftertreatment #1 DEF pump #2 DEF injector #4 (green)
(22) Aftertreatment #1 DEF pump #1 DEF injector #3 (blue)
(23) Aftertreatment #2 DEF pump #2 DEF injector #4 (red)
(24) Aftertreatment #2 DEF pump #1 DEF injector #3 (yellow)
Table 3
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -5 code is active or logged.
Proceed to Test Step 2.
Result: A -6 code is active or logged.
Proceed to Test Step 3.
2. Check the Backflow Valve Wiring Harness for an Open Circuit
A. Turn the keyswitch to the OFF position. The keyswitch must be OFF for 2 minutes to allow the DEF pump to purge, reset the code, and reset the Diesel Exhaust Fluid Controllers (DCU’s).
B. Disconnect the Pump Electronic Tank Unit (PETU) wiring harness from the affected DEF backflow valve and the affected DCU.
C. Connect the 398-5063 Probe to the DCU connector.
The probe must be used to prevent damage to the DCU connector.
D. Measure the resistance between the following terminals on the affected DEF backflow valve wiring harness connector and the affected 86-pin DCU wiring harness connector:
- For Aftertreatment #1 DCU #1, Terminal 1 (Supply) on the affected DEF backflow valve wiring harness connector and Terminal 11 (DEF Backflow Valve (+)) on the 86-pin DCU connector.
- For Aftertreatment #1 DCU #1, Terminal 2 (Return) on the affected DEF backflow valve wiring harness connector and Terminal 31 (DEF Backflow Valve (-)) on the 86-pin DCU connector.
- For Aftertreatment #1 DCU #2, Terminal 1 (Supply) on the affected DEF backflow valve wiring harness connector and Terminal 11 (DEF Backflow Valve (+)) on the 86-pin DCU connector.
- For Aftertreatment #1 DCU #2, Terminal 2 (Return) on the affected DEF backflow valve wiring harness connector and Terminal 31 (DEF Backflow Valve (-)) on the 86-pin DCU connector.
- For Aftertreatment #2 DCU #1, Terminal 1 (Supply) on the affected DEF backflow valve wiring harness connector and Terminal 11 (DEF Backflow Valve (+)) on the 86-pin DCU connector.
- For After


Parts differential Volvo Penta:

1522932
 
1522932 Differential carrier
D120A; D120AK; TD120A, RAN181; RAN280; RAN480, TD120C
1522981
 
1522981 Differential carrier
D120A; D120AK; TD120A, RAN181; RAN280; RAN480, TD120C
1522982
 
1522982 Differential carrier
D120A; D120AK; TD120A, RAN181; RAN280; RAN480, TD120C
1522980
 
1522980 Differential carrier
D120A; D120AK; TD120A, RAN181; RAN280; RAN480, TD120C
1523599
 
1523599 Differential carrier
RAN181; RAN280; RAN480
1523082
 
1523082 Differential carrier
RAN181; RAN280; RAN480
1522429
 
1522429 Differential carrier
RAN181; RAN280; RAN480
1523679
 
1523679 Differential carrier
RAN181; RAN280; RAN480
Back to top