873397 Volvo.Penta Diode retainer


873397 Diode retainer Volvo.Penta MD2010A; MD2020A; MD2030A Diode
873397 Diode retainer Volvo Penta
Rating:
58

Buy Diode retainer 873397 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 13
 

Compatible models:

Volvo Penta entire parts catalog list:

MD2010A; MD2020A; MD2030A; MD2040A; MS2B-R; MS2A-D; MS2A-E; MS2L-D; MS2L-E; 120S-D; 120S-E; MD2010; MD2030; MD2040; MD2020

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
101-13
Crankcase Air Pressure Sensor : Out of Calibration 101-13
Crankcase Air Pressure Sensor : Out of Calibration During key on, the signal voltage from the crankcase air pressure sensor indicated a crankcase air pressure greater than +/- 1.5 kPa (0.2 psi).
There is not a reference sensor for this sensor
1208-13
Engine Pre-filter Oil Pressure : Out of Calibration 542-13
Engine Oil Pressure Sensor - Before Oil Filter : Out of Calibration During key on, the signal voltage from the engine pre-filter oil pressure sensor indicated an engine pre-filter oil pressure greater than +/- 18 kPa (3 psi).
Reference sensor: Atmospheric Pressure Sensor
3563-13
Engine Intake Manifold #1 Absolute Pressure : Out of Calibration 1785-13
Intake Manifold Pressure Sensor : Out of Calibration During key on, the signal voltage from the intake manifold pressure sensor indicated an intake manifold pressure greater than +/- 18 kPa (3 psi).
Reference sensor: Atmospheric Pressure Sensor
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
Note: The engine coolant temperature must be greater than 0° C (32° F) before beginning this procedure.
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Look for active codes that are associated with the system for the event code.
Codes
Result: An associated code is active.
Repair: Troubleshoot any associated codes before continuing with this test.
Result: A code is active or logged.
Proceed to Test Step 2.
2. Check for Debris
A. Turn the keyswitch to the OFF position.
B. Check the sensor for debris.
C. If applicable, check the reference sensor for debris.
D. Check the sensor measurement port for blockage by debris.
E. If debris is found, clear the debris from the measurement port and replace the sensor.
F. Connect Cat ET.
G. Use Cat ET to monitor the following:
- Codes
Debris
Result: The sensor measurement port is not blocked by debris.
Proceed to Test Step 3.
Result: A -13 code is not active.
Return to service.
Result: A -13 code is active.
Repair: Replace the sensor. If more than one -13 code is active and the codes have a reference sensor, replace the reference sensor.
If the problem is not resolved, proceed to Test Step 3.
3. Inspect the Sensor Connector
A. Turn the keyswitch to the OFF position.
B. Inspect the sensor connector for moisture and corrosion.
Moisture
Result: The sensor connector does not have moisture or corrosion.
Proceed to Test Step 5.
Result: The sensor connector has moisture and/or corrosion.
Proceed to Test Step 4.
4. Remove any Moisture and/or Corrosion
A. Turn the keyswitch to the OFF position.
B. Disconnect the sensor connector.
C. Remove any moisture and/or corrosion from the outside of the connector. Check for moisture and corrosion inside the connector. Verify that the seals for the wires are sealing correctly. Refer to Troubleshooting, "Electrical Connectors - Inspect" for additional information.
D. If necessary, repair or replace the connector.
E. Reconnect the connector. Verify that the connection is secure.
F. Connect Cat ET.
G. Use Cat ET to monitor the following:
- Codes
Moisture
Result: A -13 code is not active.
Return the service.
Result: A -13 code is active.
Repair: Replace the sensor. If more than one -13 code is active and the codes have a reference sensor, replace the reference sensor.
If the problem is not resolved, proceed to Test Step 5.
5. Check for Moisture and/or Corrosion in the Circuit
A. Turn the keyswitch to the OFF position.
B. Check all the connectors in the circuit for moisture and/or corrosion.
C. Check for corrosion inside the connector. Verify that the seals for the wires are sealing correctly. Refer to Troubleshooting, "Electrical Connectors - Inspect" for additional information.
D. If necessary, repair or replace the connector.
E. Reconnect the connector. Verify that the connection is secure.
F. Connect Cat ET.
G. Use Cat ET to monitor the following:
- Codes
Moisture
Result: A -13 code is not active.
Return the service.
Result: A -13 code is active.
Repair: Replace the sensor. If more than one -13 code is active and the codes have a reference sensor, replace the reference sensor.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).


Parts diode Volvo Penta:

1698689
 
1698689 Diode bridge
2001; 2001B; 2001AG, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D2-55; D2-55B; D2-55C, KAD32P; TAMD42WJ-A; KAD43P-A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P-A; HS1A, MD2010-C; MD2010-D; MD2020-C, MD2010A; MD2020A; MD
20382270
 
20382270 Diode
1372, 430; 430A; 430B, 5.0GXiCE-J; 5.0GXiCE-JF; 5.0GXiCE-M, 5.0GXiE-JF; 5.0GXiE-J; 5.0OSiE-JF, 5.7GiCE-300-J; 5.7GiCE-300-JF; 5.7GXiCE-J, 5.7GiE-300-J; 5.7GiE-300-JF; 5.7GXiE-J, 8.1GiCE-J; 8.1GiCE-JF; 8.1GiCE-M, 8.1GiE-JF; 8.1GiE-J; 8.1OSiE-JF, 8.1IP
1624394
 
1624394 Diode
KAD42B; KAMD42B; TAMD42B, MD2010A; MD2020A; MD2030A, MD22A; MD22A-A; MD22L-A, TD61A; TD61AW; TD61ACE, TID162AG; TID162AGP; TID162AP, TMD100C
Back to top