Parameter Descriptions
"Product ID"
The "Product ID" parameter allows the customer to enter a description into the ECM in order to identify the machine. A maximum of eight characters can be entered in the field."Equipment ID"
The "Equipment ID" parameter allows the customer to enter a description into the ECM in order to identify the machine. A maximum of 17 characters can be entered in the field."Engine Serial Number"
Program the "Engine Serial Number" to match the engine serial number that is stamped on the engine information plate. The engine serial number is not preprogrammed on a replacement ECM."FLS" (Full Load Setting)
"FLS" is the adjustment to the fuel system that was made at the factory in order to fine-tune the fuel system. The correct value for this parameter is stamped on the engine information plate. Only change this value if the engine is rerated or if a new ECM is installed. Factory passwords are required."FTS" (Full Torque Setting)
"FTS" is similar to "FLS". Only change this value if the engine is rerated or if a new ECM is installed. Factory passwords are required."Engine Fan Control"
The "Engine Fan Control" parameter allows the operation of this feature to be enabled or disabled."Engine Fan Reversing Feature"
The "Engine Fan Reversing Feature" parameter allows the operation of this feature to be enabled or disabled. The feature changes the direction of the fan momentarily in order to purge debris from the radiator cores and grill. Reversing the airflow can be activated by a manual control or by setting an automatic purge cycle."Engine Fan Purge Cycle Interval"
The automatic setting for the engine fan purge cycle interval can be adjusted from every 3 minutes to every 60 minutes. The setting has an incremental adjustment of one minute."Security System Immobilizer Installation Status"
The security system immobilizer shuts off fuel injection to the engine. This feature requires Machine Security System (MSS) installation to be set to "Installed". If the machine is equipped with the MSS, set the security system immobilizer installation status to "Installed". A factory password is required to enable this feature."Ether Solenoid Configuration"
The ether attachment is available as a cold start aid. Set the parameter to "Continuous Flow Solenoid " if the machine is equipped with ether."Low System Battery Voltage Elevated Idle"
The "Low System Battery Voltage Elevated Idle" enables monitoring of the battery voltage while the machine is idling. If the battery voltage drops below 24.5 V, the engine speed is increased to 1100 rpm. The feature helps to reduce the risk of the battery becoming fully discharged. The feature becomes active when the following conditions are met:
The transmission is in neutral.
The parking brake is engaged.
The throttle pedal is not depressed for greater than five percent.
Five minute have elapsed.The "Machine Working Engine Low Idle Speed Configuration" rpm will return if one of the following conditions are met:
The parking brake is released.
A directional shift occurs.
The governor pedal is pushed."Engine Warm-up Elevated Idle Feature Enable Status"
The engine warm-up elevated idle feature is designed to keep the engine and the machine warmer in cold-weather operations. The warm-up mode is engaged after ten minutes and the following conditions are met:
The transmission is in neutral.
The parking brake is engaged
The throttle pedal is not depressed for greater than five percent.The software will monitor coolant and inlet manifold temperature. When the coolant temperature drops below 70° C (158° F) and the inlet manifold temperature drops below 5° C (41° F), the engine idle speed will increase to 1100 rpm. The warm-up mode is discontinued when the coolant temperature reaches 80° C (176° F). The "Machine Working Engine Low Idle Speed Configuration" rpm will return if one of the following conditions is met:
The parking brake is released.
A directional shift occurs.
The governor pedal is pushed.After the first time warm-up mode has been engaged, the following conditions will reactivate warm-up mode:
One minute has elapsed.
The coolant temperature is below 70° C (158° F)."Machine Working Engine Low Idle Speed Configuration"
The "Machine Working Engine Low Idle Speed Configuration" is the engine rpm for the machine during normal operation. The engine idle rpm may be set for work mode in order to meet the application requirements."Machine Hibernating Engine Low Idle Speed Configuration"
The machine hibernate engine low idle speed provides lower fuel consumption and reduced sound and emissions levels in applications with considerable idle time. The hibernate mode is engaged after ten seconds and the following conditions are met:
The transmission is in neutral.
The parking brake is engaged.
The implement hydraulic levers are in neutral positions.
The throttle pedal is not depressed for greater than five percent.
The fan current is greater than 0.8 amp and the engine temperature is greater than 50° C (122° F)The "Machine Working Engine Low Idle Speed Configuration" rpm will return if one of the following conditions are met:
The parking brake is released.
A directional shift occurs.
A hydraulic lever is moved.
The governor pedal is pushed.The machine hibernating engine low idle speed configuration can be set in the range of 600 to 825 rpm."Engine Idle Shutdown Enable Status"
This feature enables the ECM to shut down the engine after the Engine Idle Shutdown Delay Time has expired."Engine Idle Shutdown Delay Time"
The delay time is the amount of time that the engine is allowed to idle prior to shutdown if the machine is not being operated.Parameter Table
Table 1
Customer Specified Parameters
Parameter Available Range or Options Default Required Password
"Product ID" eight characters blank none
"Equipment ID" 17 characters blank none
"Engine Serial Number" eight characters blank none
"FLS" -128 to +127 0 Factory