3584388 Volvo.Penta Elbow nipple


3584388 Elbow nipple Volvo.Penta D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F Elbow
3584388 Elbow nipple Volvo Penta
Rating:
53

Buy Elbow nipple 3584388 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 5
 

Volvo Penta entire parts catalog list:

D4-180I-B; D4-180I-C; D4-180I-D; D4-180I-E; D4-210A-A; D4-225A-B; D4-210I-A; D4-210I-B; D4-225I-B; D4-225A-C; D4-225A-D; D4-225I-C; D4-225I-
D4-180I-F; D4-225A-F; D4-225I-F; D4-260A-F; D4-260D-F; D4-260I-F; D4-300A-F; D4-300D-F; D4-300I-F
D6-280A-A; D6-280A-B; D6-280A-C; D6-280A-D; D6-280A-E; D6-280I-A; D6-280I-B; D6-280I-C; D6-280I-D; D6-280I-E; D6-310I-A; D6-310A-A; D6-310A-
D6-300A-F; D6-300D-F; D6-300I-F; D6-330A-F; D6-330D-F; D6-330I-F; D6-370A-F; D6-370D-F; D6-370I-F; D6-400A-F; D6-435D-F; D6-435I-F; D6-435I-

Information:


Illustration 1 g00835551
Typical schematicTest Step 1. Check for an Open Circuit in the OFF/RESET position.
If equipped, disconnect the remote start/stop initiate contacts from the terminal strip in the Generator Terminal box.
Disconnect the harness connector from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Turn the ECS to the OFF/RESET position.
At the GSC+ harness connector, measure the resistance from contact "39" to the − Battery terminal of the relay module. Measure the resistance from contacts "32", "33" and "40" to the − Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "39" to the − Battery terminal of the relay module should be 5 Ohms or less. The resistance that is measured from contacts "32", "33" and "40" to the − Battery terminal should be greater than 5000 Ohms.Results:
OK - All resistance measurements are correct. Proceed to test step 2.
Not OK - The resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the − Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after troubleshooting is complete.STOPTest Step 2. Check for an Open Circuit in the AUTO position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the Generator Terminal box.
The harness connector remains disconnected from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Place the ECS in the AUTO position. Measure the resistance from contact "40" of the GSC+ harness connector to the − Battery terminal of the relay module. Measure the resistance from contacts "32", "33" and "39" to the − Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "40" to the − Battery terminal of the relay module should be 5 Ohms or less. The resistance that is measured from contacts "32", "33" and "39" to the − Battery terminal should be greater than 5000 Ohms.Results:
OK - The resistance measurements are correct. Proceed to test step 3.
Not OK - The resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the − Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed.STOPTest Step 3. Check for an Open Circuit in the MAN/START position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the Generator Terminal box.
The harness connector remains disconnected from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Place the ECS in the MAN/START position. Measure the resistance from contact "33" of the GSC+ harness connector to the − Battery terminal of the relay module. Measure the resistance from contacts "32", "39" and "40" to the − Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "33" to the − Battery terminal of the relay module should be 5 Ohms or less. The resistance that is measured from contacts "32", "39" and "40" to the − Battery terminal should be greater than 5000 Ohms.Results:
OK - The resistance measurements are correct. Proceed to test step 4.
Not OK - The resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the − Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed.STOPTest Step 4. Check for an Open Circuit in the COOLDOWN/STOP position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the Generator Terminal box.
The harness connector remains disconnected from the GSC+.


Parts elbow Volvo Penta:

3583959
 
3583959 Elbow nipple
D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F
984412
 
984412 Elbow nipple
D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F
3863252
 
3863252 Elbow
D4-180I-F; D4-225A-F; D4-225I-F, D6-300A-F; D6-300D-F; D6-300I-F
Back to top