3840609 Exhaust riser Volvo.Penta
D6-280A-A; D6-280A-B; D6-280A-C
Exhaust
Price: query
Rating:
Compatible models:
D6-280A-A; D6-280A-B; D6-280A-C
Volvo.Penta
Volvo Penta entire parts catalog list:
- Exhaust Riser Kit, AQ » 3840609
Information:
Table 1
Alternative     Default    
"Cab Switches"
"Remote Switches"
"Remote Throttle"     "Off"    "PTO Top Engine Limit"
The "PTO Top Engine Limit" is the top engine limit that is available by using a PTO on/off circuit that is connected to J1/P1:56 (Input 1). Note: The "PTO Configuration" must be programmed to "Cab Switches", "Remote Switches", or "Remote Throttle" before this parameter can be programmed.
Table 2
Minimum     Maximum     Default    
700     TEL rpm     TEL rpm    "PTO Engine RPM Set Speed (0 = Off)"
The "PTO Engine RPM Set Speed (0 = Off)" is the engine rpm that is allowed by the ECM when the PTO on/off circuit is on and the set switch is actuated.If the "PTO to Set Speed" parameter is programmed to "YES", the engine will proceed to this speed whenever the PTO on/off circuit is turned on.Note: "PTO Configuration" must be programmed to "Cab Switches" or "Remote Switches" for this parameter to function.This parameter must be programmed higher than the programmed low idle. If the "PTO to Set Speed" is programmed to a higher value than the "PTO Top Engine Limit", the set speed will be limited by the lower "PTO Top Engine Limit".For one rpm set speed above low idle, program the "PTO Top Engine Limit" to the same rpm as the "PTO Engine RPM Set Speed".For two rpm set speeds above low idle, program this parameter to some intermediate value between the low idle and the "PTO Top Engine Limit".Place the PTO on/off switch to the ON position. Toggle the set switch once in order to cause the rpm to advance to the "PTO Engine RPM Set Speed". Toggle the set switch again in order to increase the engine rpm to the "PTO Top Engine Limit". Toggling the resume switch decreases the engine rpm to the previous set speed.
Table 3
Minimum     Maximum     Default    
Low Idle rpm     PTO TEL rpm     0 rpm    "PTO Engine RPM Set Speed A"
If the "PTO Engine RPM Set Speed A" parameter is programmed to the corresponding switch input option, the switch is used in order to control engine speed during PTO operation. The "PTO Configuration" parameter must be programmed to "Cab Switches", to "Remote Switches", or to "Remote Throttle" and the "PTO Engine RPM Set Speed A" parameter must be programmed to a valid speed.
Table 4
Minimum     Maximum     Default    
Low Idle rpm     PTO TEL rpm     0 rpm    "PTO Engine RPM Set Speed B"
If the "PTO Engine RPM Set Speed B" parameter is programmed to the corresponding switch input option, the switch is used in order to control engine speed during PTO operation. The "PTO Configuration" parameter must be programmed to "Cab Switches", to "Remote Switches", or to "Remote Throttle" and the "PTO Engine RPM Set Speed B" parameter must be programmed to a valid speed.
Table 5
Minimum     Maximum     Default    
Low Idle rpm     PTO TEL rpm     0 rpm    "PTO to Set Speed"
This parameter causes the ECM to proceed to the programmed "PTO Engine RPM Set Speed" when the PTO on/off switch is on. "PTO Configuration" must be programmed to "Cab Switches" or to "Remote Switches" before this parameter can be programmed.Note: This parameter is not available when "PTO Configuration" is programmed to "Remote Throttle".
Table 6
Alternative     Default    
"Yes"     "No"    "Maximum PTO Enable Speed"
This parameter specifies the maximum engine speed for the engagement of the PTO mode. The PTO mode will engage when the engine rpm is equal to the programmed limit or less than the programmed limit.
Table 7
Minimum     Maximum     Default    
700 rpm     TEL rpm     TEL rpm    "PTO Cab Throttle RPM Limit"
This determines the engine rpm limit of the pedal position sensor for the cab accelerator and for the cab set/resume switch when "PTO Configuration" is programmed to "Cab Switches" and the PTO on/off circuit is ON. This parameter is intended to prevent engine overspeed when the dedicated PTO is used.
If the parameter is programmed to "Low Idle", the cab controls are ignored.
If the parameter is programmed to "Top Engine Limit" (TEL), the engine will operate to the programmed "Top Engine Limit".
If the parameter is programmed to "PTO Top Engine Limit", the engine w
Parts exhaust Volvo Penta:
3584167
3584167 Exhaust hose
D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F, DPH-A; TSK DPH-B; TSK DPH-A, DPH-D; DPR-D; DPH-D1
3584168
3584168 Exhaust hose
D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F, DPH-A; TSK DPH-B; TSK DPH-A, DPH-D; DPR-D; DPH-D1
21114146
21114146 Exhaust pipe
D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F, DPH-A; TSK DPH-B; TSK DPH-A, DPH-D; DPR-D; DPH-D1
21698559
21698559 Exhaust pipe
D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F, DPH-A; TSK DPH-B; TSK DPH-A, DPH-D; DPR-D; DPH-D1
21187492
3587370
3587159
3887981