Information:


Table 1
Diagnostic Codes Table    
Code and Description    Conditions which Generate this Code    System Response    
1-5 Cylinder #1 Injector current below normal     The engine's Electronic Control Module (ECM) detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
1-6 Cylinder #1 Injector current above normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
2-5 Cylinder #2 Injector current below normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
2-6 Cylinder #2 Injector current above normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
3-5 Cylinder #3 Injector current below normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
3-6 Cylinder #3 Injector current above normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
4-5 Cylinder #4 Injector current below normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
4-6 Cylinder #4 Injector current above normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
5-5 Cylinder #5 Injector current below normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
5-6 Cylinder #5 Injector current above normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
6-5 Cylinder #6 Injector current below normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
6-6 Cylinder #6 Injector current above normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
7-5 Cylinder #7 Injector current below normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
7-6 Cylinder #7 Injector current above normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
8-5 Cylinder #8 Injector current below normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
8-6 Cylinder #8 Injector current above normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
9-5 Cylinder #9 Injector current below normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
9-6 Cylinder #9 Injector current above normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
10-5 Cylinder #10 Injector current below normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
10-6 Cylinder #10 Injector current above normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
11-5 Cylinder #11 Injector current below normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
11-6 Cylinder #11 Injector current above normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
12-5 Cylinder #12 Injector current below normal     The ECM detects an open circuit.     The code is logged.
The ECM continues to fire the injector solenoid.    
12-6 Cylinder #12 Injector current above normal     The ECM detects a short circuit.     The code is logged.
The ECM will disable the solenoid circuit. The ECM will periodically try to fire the injector. If the short circuit remains, this sequence of events will be repeated until the problem is corrected.    
13-5


Parts extension Volvo Penta:

846648
Extension cable
846648 Extension cable
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQD70D; TAMD70D; TAMD70E, D1-13; D1-13B; D1-20, D12D-A MH; D12D-B MH; D12D-C MH, D2-55; D2-55B; D2-55C, D2-75; D2-75B; D2-75C, KAD32P
846649
Extension cable
846649 Extension cable
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQD70D; TAMD70D; TAMD70E, D1-13; D1-13B; D1-20, D12D-A MH; D12D-B MH; D12D-C MH, D2-55; D2-55B; D2-55C, D2-75; D2-75B; D2-75C, KAD32P
846650
 
846650 Extension cable
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQD70D; TAMD70D; TAMD70E, D1-13; D1-13B; D1-20, D12D-A MH; D12D-B MH; D12D-C MH, D2-55; D2-55B; D2-55C, D2-75; D2-75B; D2-75C, KAD32P
880695
 
880695 Extension bar
AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, D42A; D42A PP, D70B; D70B PP; D70B K, D70CHC; D70CRC; TD70CHC, DH10A; DH10A 285; DH10A 360, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B;
873912
 
873912 Extension cable
KAD32P; TAMD42WJ-A; KAD43P-A, TAMD122A; TMD122A; TAMD122P-A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B
873861
Extension cable
873861 Extension cable
KAD32P; TAMD42WJ-A; KAD43P-A, TAMD122A; TMD122A; TAMD122P-A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B
873905
 
873905 Extension cable
KAD32P; TAMD42WJ-A; KAD43P-A, TAMD122A; TMD122A; TAMD122P-A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B
873906
 
873906 Extension cable
KAD32P; TAMD42WJ-A; KAD43P-A, TAMD122A; TMD122A; TAMD122P-A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TAMD74A; TAMD74A-A; TAMD74A-B
Back to top