3825685 Volvo.Penta Fan guard


3825685 Fan guard Volvo.Penta D5A-T; D5A-TA; D5A-B TA, TAD1030G; TD1010G; TWD1010G, TD100G-87; TD1030VE; TAD1030V, TD610G; TWD610G; TD710G, TD610V; TWD610V; TD630VE, TD61A; TD61AW; TD61ACE, TD71A; TID71A; TWD710V, TWD610P; TWD610PB; TWD710P Fan
3825685 Fan guard Volvo Penta
Rating:
8

Buy Fan guard 3825685 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 30
 

Volvo Penta entire parts catalog list:

D5A-T; D5A-TA; D5A-B TA; D7A-T; D7A-TA; D7A-B TA
TAD1030G; TD1010G; TWD1010G
TD100G-87; TD1030VE; TAD1030V; TWD1031VE; TAD1030VE
TD610G; TWD610G; TD710G; TWD710G; TAD730G; TWD740GE; TAD740GE; TAD741GE
TD610V; TWD610V; TD630VE; TWD630VE; TD640VE; TWD610PB
TD61A; TD61AW; TD61ACE; TD61AG; TD61AGP; TD61AP; TD61APB; TID61AG; TD71A; TD71AW; TD71ACE; TD71AG; TD71AGP; TD71AP; TD71APB; TID71A; TID71AG; TID
TD71A; TID71A; TWD710V; TD730VE; TWD731VE; TAD730V; TWD740VE
TWD610P; TWD610PB; TWD710P; TWD710PB; TAD730P

Information:


Illustration 1 g00838828
Typical schematic
Illustration 2 g01090782
P1 ECM connector (P1-22) Ether hold relay (P1-25) Ether request (P1-29) Digital return (P1-40) Ether start relayTest Step 1. Check for Connector Damage
Turn the keyswitch to the OFF position.
Thoroughly inspect the ECM connectors J1/P1. Inspect all of the other connectors. Refer to Troubleshooting, "Inspecting Electrical Connectors" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque of 6.0 N m (55 lb in).
Check the customer connector (allen head screw) for the proper torque of 2.25 0.25 N m (20 2 lb in).
Check the harness and the wiring for abrasion and for pinch points.Expected Result:The connectors and wiring are free of the following problems: damage, corrosion, abrasion and incorrect attachment.Results:
OK - The connectors and wiring are OK. Proceed to Test Step 2.
Not OK - The connectors and/or wiring are not OK.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Verify that the system is operating correctly.STOPTest Step 2. Check the Ether Canisters
Turn the keyswitch to the OFF position.
Remove the ether canister from the ether solenoid. Determine if the canister contains any ether. Ether can not be injected if the canister is empty.Expected Result:The ether canister is not empty.Results:
OK - The ether canister is not empty. Proceed to Test Step 3.
Not OK - The ether canister is empty.Repair: Replace the empty ether canister with a full ether canister. Verify that the system is operating correctly.STOPTest Step 3. Check for Diagnostics on the Caterpillar Electronic Technician (ET)
Remove the ether canister from the ether solenoid.
Connect Cat ET to the cab service tool connector J42. Start Cat ET.
Turn the keyswitch to the ON position.
Toggle the starting aid switch. Observe the parameter for the starting aid switch on Cat ET.
Determine if CID-FMI 545-05, 545-06, 546-05 or 546-06 is active or logged.Expected Result:The parameter for the starting aid switch displays "ON" while the starting aid switch is toggled. The parameter for the starting aid switch displays "OFF" when the starting aid switch is released. An active diagnostic code is present or a logged diagnostic code is present.Results:
OK - Active Code - The parameter for the starting aid switch displays "ON" while the starting aid switch is toggled. The parameter for the starting aid switch displays "OFF" when the starting aid switch is released. Active diagnostics are displayed. Proceed to Test Step 4.
OK - Logged Code - The parameter for the starting aid switch displays "ON" while the starting aid switch is toggled. The parameter for the starting aid switch displays "OFF" when the starting aid switch is released. Logged diagnostics are displayed. Repair: Check for an intermittent short or for an open in the wiring or in the connectors. Refer to Troubleshooting, "Inspecting Electrical Connectors". Repair any suspect connectors or wiring and/or replace the connectors or wiring. Verify that the system is operating correctly. Replace the ether canister on the ether solenoid.STOP
Not OK - The parameter for the starting aid switch does not display "ON" while the starting aid switch is toggled. The parameter for the starting aid switch does not display "OFF" when the starting aid switch is released. The starting aid switch is not functioning correctly. Proceed to Test Step 15.Test Step 4. Check the Voltage from the Ether Start Relay
Turn the keyswitch to the OFF position.
Connect a voltmeter between wire 317-YL on terminal 87 of the ether start relay and ground.
Turn the keyswitch to the ON position.
Select the "Diagnostic Tests" on Cat ET.
Do not allow the ether injection system to be on for more than two minutes. Damage to the ether solenoid may occur.
Select the "Override Parameters" screen on Cat ET.
Activate the ether override and observe the voltmeter while the ether injection is activated.
Disable the ether override.Expected Result:The voltage at the ether start relay is 24 3 VDC during the first two seconds of injection. The voltage then decreases to 3 1 VDC for the remainder of the injection duration.Results:
OK - The voltage is approximately 24 3 VDC for the first two seconds. The voltage then decreases to approximately 3 1 VDC for the remainder of injection duration. Proceed to Test Step 5.
Not OK - 24 VDC - The voltage did not measure 24 3 VDC. Proceed to Test Step 6.
Not OK - 3 VDC - The voltage did not decrease to 3 1 VDC for the remainder of the injection duration. Proceed to Test Step 9.Test Step 5. Check the Voltage at the Ether Solenoid
Turn the keyswitch to the OFF position.
Disconnect the ether solenoid connector at the solenoid.
Connect a voltmeter to terminal 1 and terminal 2 of the ether solenoid connector.
Turn the keyswitch to the ON position.


Parts fan Volvo Penta:

840621
 
840621 Fan
2001; 2001B; 2001AG, 230A; 230B; 250A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A, AQ200B
3827492
 
3827492 Fan
1372, TAD1030GE; TAD1031GE; TAD1032GE, TAD1140VE; TAD1141VE; TAD1142VE, TAD1150VE; TAD1151VE; TAD1152VE, TAD1170VE; TAD1171VE; TAD1172VE, TAD1340VE; TAD1341VE; TAD1342VE, TAD1350VE, TAD1351VE; TAD1352VE; TAD1353VE, TAD1352VE, TAD1360VE, TAD1361VE, TA
844696
 
844696 Fan shroud
D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, TAD1030G; TD1010G; TWD1010G, TD100CHC; TD100CRC; TD121CHC, TD100G; TD100G-85; TD100G-87, TMD102A; TAMD102A; TAMD102D
863221
 
863221 Fan, suction type
TAD1030G; TD1010G; TWD1010G, TD100G; TD100G-85; TD100G-87
863225
Fan, pusher type
863225 Fan, pusher type
TAD1030G; TD1010G; TWD1010G, TD100G; TD100G-85; TD100G-87
1544942
 
1544942 Fan ring
TD100G-87; TD1030ME; TWD1030ME, TD100G-87; TD1030VE; TAD1030V
1674069
 
1674069 Fan, suction type
TD100G-87; TD1030ME; TWD1030ME, TD100G-87; TD1030VE; TAD1030V
3828620
 
3828620 Fan
TD610M; TD630ME; TWD630ME, TD610V; TWD610V; TD630VE, TD71A; TID71A; TWD710V
Back to top