21718912 Volvo.Penta Filter


21718912 Filter Volvo.Penta D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D6-280A-A; D6-280A-B; D6-280A-C, D6-300A-F; D6-300D-F; D6-300I-F Filter
21718912 Filter Volvo Penta
Rating:
103

Buy Filter 21718912 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$23.69

22-12-2024

CN: Ruijin Longyin Impor
Compass-Yang Fuel Filter Fuel Water Separator 21718912 Compatible with Volvo Penta Engine D4 D6 engines
Compass-Yang Part Number:21718912 21540371 || Compatible with Volvo Penta Engine D4:D4-180i-B, D4-180I-C, D4-210A-A, D4-210A-B, D4-210i-A, D4-210i-B, D4-225A-B, D4-225A-C, D4-225i-B, D4-225I-C, D4-260A-A, D4-260A-B, D4-260A-C, D4-260D-B, D4-260DC, D4-260i-A, D4-260i-B, D4-260I-C, D4-300A-A, D4-300A-C, D4-300D-A, D4-300D-C, D4-300I-A, D4-300I-C || Compatible with Volvo Penta Engine D6:D6-280A-A, D6-280A-B, D6-280i-A, D6-280i-B, D6-310A-A,D6-310A-B, D6-310D-A, D6-310D-B, D6-310i-A, D6-310i-B, D6-330A-B, D6-330A-C, D6-330D-B, D6-330D-C, D6-330I-B, D6-330I-C, D6-350A-A, D6-350A-B, D6-370A-B, D6-370A-C, D6-370D-A, D6-370D-B, D6-370D-C, D6-370i-A, D6-370i-B, D6-370I-C, D6-435D-A, D6-435D-C, D6-435i-A, D6-435I-C || It Is a Replacement Part Not Original Part. But It Can Work Good For You || Manufactured to OEM standards and rigorously tested at the factory
$282.84

26-11-2024

KR: Adabus
Oil Filter for Volvo Penta 3583443 21718912
Generic
$77.15

08-10-2024
0.1102[0.05] pounds
CN: YANLILIBAO
BHUPWZE Fuel Filter 21718912 SP1559M 21540371 SN30039 P767293 Compatible-PENTA MARINE Fuel Water Separation Filter
BHUPWZE Other Part Number : 21718912 SP1559M 21540371 SN30039 P767293 || Placement on Vehicle : fuel filter || Interchange Part Number : SP1559M 21540371 SN30039 P767293 || Special Features : replacement filter || Material Type : paper
Number on catalog scheme: 8
 

Volvo Penta entire parts catalog list:

D4-180I-B; D4-180I-C; D4-180I-D; D4-180I-E; D4-210A-A; D4-225A-B; D4-210I-A; D4-210I-B; D4-225I-B; D4-225A-C; D4-225A-D; D4-225I-C; D4-225I-
D4-180I-F; D4-225A-F; D4-225I-F; D4-260A-F; D4-260D-F; D4-260I-F; D4-300A-F; D4-300D-F; D4-300I-F
D6-280A-A; D6-280A-B; D6-280A-C; D6-280A-D; D6-280A-E; D6-280I-A; D6-280I-B; D6-280I-C; D6-280I-D; D6-280I-E; D6-310I-A; D6-310A-A; D6-310A-
D6-300A-F; D6-300D-F; D6-300I-F; D6-330A-F; D6-330D-F; D6-330I-F; D6-370A-F; D6-370D-F; D6-370I-F; D6-400A-F; D6-435D-F; D6-435I-F; D6-435I-

Information:


Illustration 1 g01800518
Schematic for the sensors
Illustration 2 g01458448
Pin locations on the P2 connector for the pressure sensors
(38) Ground (GND) Intake Manifold Pressure Sensor
(39) Ground (GND) Oil Pressure Sensor
(40) Ground (GND) Fuel Rail Pressure Sensor
(46) Voltage supply (5 VDC) Intake Manifold Pressure Sensor
(47) Voltage supply (5 VDC) Oil Pressure Sensor
(48) Voltage supply (5 VDC) Fuel Rail Pressure Sensor
(51) Signal (SIG) Fuel Rail Pressure Sensor
(55) Signal (SIG) Intake Manifold Pressure Sensor
(56) Signal (SIG) Oil Pressure Sensor
Illustration 3 g01170309
Fuel rail pressure sensor
(1) Voltage supply (Vs)
(2) Ground (GND)
(3) Signal (SIG)
Illustration 4 g01170310
Intake manifold pressure sensor
(1) Voltage Supply (Vs)
(2) Ground (GND)
(3) Signal (SIG)
Illustration 5 g01170311
Oil pressure sensor
(1) Voltage Supply (Vs)
(2) Ground (GND)
(3) Signal (SIG) The troubleshooting procedures for the diagnostic codes of each pressure sensor are identical. The pressure sensors are active sensors. The pressure sensor has three terminals. Active sensors require supply voltage from the ECM. The P2/J2 ECM connector supplies +5 VDC to terminal 1 of each sensor. The common line is connected to each sensor connector terminal 2. The signal voltage from terminal 3 of each sensor is supplied to the appropriate terminal at the P2/J2 ECM connector.Test Step 1. Verify All Active Diagnostic Codes
Turn the keyswitch to the ON position. Wait at least 10 seconds for activation of the diagnostic codes.
Verify if any of the following diagnostic codes are active:
100-3 Engine Oil Pressure Sensor voltage above normal
100-4 Engine Oil Pressure Sensor voltage below normal
100-10 Engine Oil Pressure Sensor abnormal rate of change
1785-3 Intake Manifold Pressure Sensor voltage above normal
1785-4 Intake Manifold Pressure Sensor voltage below normal
1785-10 Intake Manifold Pressure Sensor abnormal rate of change
1797-3 Fuel Rail Pressure Sensor voltage above normal
1797-4 Fuel Rail Pressure Sensor voltage below normalExpected Result:One or more of the preceding diagnostic codes are active.Results:
OK - Proceed to Test Step 2.
Not OK - Repair: Do not use this procedure if 1785-10 or 100-10 diagnostic codes are active. Refer to Troubleshooting, "5 Volt Sensor Supply Circuit - Test". When this test is complete, return to the start of this test. If the preceding codes are logged, an intermittent condition may be causing the logged codes. Refer to Troubleshooting, "Electrical Connectors - Inspect".Perform a "Wiggle Test" by using the electronic service tool in order to identify intermittent connections.STOPTest Step 2. Inspect Electrical Connectors And Wiring
Thoroughly inspect the terminal connections on the P2/J2 ECM connectors.
Thoroughly inspect the following connectors for the engine pressure sensors:
P201 Engine Oil Pressure Sensor
P228 Fuel Rail Pressure Sensor
P200 Intake Manifold Pressure Sensor
Refer to Troubleshooting, "Electrical Connectors - Inspect".
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector and the sensor connectors that are associated with the active diagnostic code.
Check the screw for the ECM connector for the correct torque of 5 N m (44 lb in).
Check the harness for abrasions and for pinch points from the sensors back to the ECM.
Use the electronic service tool to perform a "Wiggle Test". The "Wiggle Test" will identify intermittent connections. Expected Result:All connectors, pins, and sockets must be coupled correctly. The harness should be free of corrosion, abrasions, and pinch points.Results:
OK - Proceed to Test Step 3.
Not OK - Repair: Repair the connectors or the harness and/or replace the connectors or the harness. Ensure that all of the seals are correctly in place and ensure that the connectors are coupled correctly.Use the electronic service tool in order to clear all logged diagnostic codes and then verify that the repair eliminates the fault.STOPTest Step 3. Verify that the Diagnostic Code is Still Active
Turn the keyswitch to the ON position. Wait at least 10 seconds for activation of the diagnostic codes.
Use the electronic service tool to check for active diagnostic codes. Record all active diagnostic codes.
Determine if the fault is related to an open circuit diagnostic code or a short circuit diagnostic code. Expected Result:Either a short circuit diagnostic code is active or an open circuit diagnostic code is active.Results:
OK - Short Circuit - A voltage above normal diagnostic code is active at this time. Proceed to Test Step 4.
OK - Open Circuit - A voltage below normal diagnostic code is active at this time. Proceed to Test Step 5.
Not OK - A short circuit diagnostic code is not active. An open circuit diagnostic code is not active. An intermittent fault may exist.Repair: Use the electronic service tool to perform a "Wiggle Test". If faults are indicated, proceed to the appropriate procedure.STOPTest Step 4. Disconnect The Sensor I