Illustration 1 g00712248
This schematic shows the injector returns on terminals 2 and 4 of the valve cover base harness.
Illustration 2 g01050844
This schematic shows the injector returns on terminals 2 and 3 of the valve cover base harness.
Illustration 3 g00893822
12 cylinder P2 ECM connector (5) Solenoid 1/3 Return (11) Solenoid 2/4 Return (12) Solenoid 12 Power (16) Solenoid 1 Power (17) Solenoid 5/7 Return (18) Solenoid 10 Power (21) Solenoid 6/8 Return (22) Solenoid 8 Power (26) Solenoid 3 Power (27) Solenoid 9/11 Return (28) Solenoid 6 Power (31) Solenoid 11 Power (32) Solenoid 5 Power (33) Solenoid 10/12 Return (34) Solenoid 4 Power (37) Solenoid 9 Power (38) Solenoid 7 Power (40) Solenoid 2 PowerTest Step 1. Inspect Electrical Connectors And Wiring
Electrical shock hazard. The electronic unit injector system uses 90-120 volts.
Turn the keyswitch to the OFF/RESET position. A strong electrical shock hazard is present if the ignition key is not turned OFF.
Thoroughly inspect the J2/P2 ECM connector and the J52/P52 through J58/P58 unit injector connectors. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Check the harness and wiring for abrasion and pinch points from the injectors to the ECM.Expected Result:All connectors, pins, and sockets are completely inserted and coupled. The harness and wiring are free of corrosion, of abrasion, and of pinch points.Results:
OK - Proceed to Test Step 2.
Not OK - Repair: Repair the circuit. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled.Verify that the repair eliminates the problem. Stop.Test Step 2. Check for Logged Diagnostic Codes
Connect the Caterpillar Electronic Technician (Cat ET) to the service tool connector.
Turn the keyswitch to the ON position.
Observe the diagnostic codes on Cat ET.Expected Result:The following diagnostic codes are not logged:
1-05 Injector Cylinder 1 open circuit through 12-05 Injector Cylinder 12 open circuit
1-06 Injector Cylinder 1 short through12-06 Injector Cylinder 12 shortResults:
OK - None of the diagnostic codes are logged. Proceed to Test Step 3.
Not OK - One or more of the diagnostic codes are logged. Proceed to Test Step 4.Test Step 3. Perform the Injector Solenoid TestNote: This test will help the service technician verify that the ECM can fire the injector solenoids. Do not try to crank the engine during this test. The ECM will terminate the injector solenoid test.
Turn the keyswitch to the ON position.
Perform the injector solenoid test on Cat ET.
As each solenoid is energized by the ECM an audible click can be heard at the valve mechanism cover. Listen for a click at each valve mechanism cover.Note: Repeat the injector solenoid test a few times in order to verify that the ECM is energizing each solenoid.Expected Result:As each solenoid is energized by the ECM, an audible click of the solenoid is heard. The solenoids are energized one at a time in numerical order from 1 through 12. There is a momentary delay between each one.Results:
OK - All of the solenoids were energized. Proceed to Test Step 9.
Not OK - One or more of the solenoids did not energize. Proceed to Test Step 4.Test Step 4. Check the Harness Resistance
Electrical shock hazard. The electronic unit injector system uses 90-120 volts.
Turn the keyswitch to the OFF/RESET position.
Disconnect the J2/P2 ECM connector.
Measure the resistance at the P2 ECM connector between the terminals for each solenoid.Expected Result:The resistance is less than 10 Ohms.Results:
OK - Proceed to Test Step 5.
Not OK - There is an open in the harness or there is an open in the injector solenoid. Proceed to Test Step 6.Test Step 5. Check the Harness for Shorts
Disconnect the J52/P52 through J58/P58 unit injector connectors.
Measure the resistance at the P2 ECM connector between the terminals for each solenoid.Expected Result:The resistance is greater than 20,000 Ohms.Results:
OK - There are no shorts in the harness or in the connectors. Proceed to Test Step 7.
Not OK - There is a short in the harness or in the connectors.Repair: Repair the circuit.Verify that the repair eliminates the problem. Stop.Test Step 6. Isolate the Open Circuit
Electrical shock hazard. The electronic unit injector system uses 90-120 volts.
Turn the keyswitch to the OFF/RESET position.
Disconnect the suspect injector at the valve cover base.
Measure the solenoid resistance of the suspect injector at the valve cover base (J52 through J58). .Note: These engines have been built with the injector returns on terminals 2 and 3 or with the injector returns on terminals 2 and 4. Check the injector returns on the valve cover base harness in order to determine if Illustration 1 or Illustration 2 references your engine.Expected Result:Resistance is less than 3.6 Ohms.Results:
OK - There is an open circuit or excessive resistance in the harness or in the connectors.Repair: Repair the circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect".Verify that the repair eliminates the problem. Stop.
Not OK - Th


Parts flange Volvo Penta:

990939
Flange nut
990939 Flange nut
1372, D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D1
984735
 
984735 Flange screw
1372, D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D1
990940
Flange nut
990940 Flange nut
1372, D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D1
984736
Flange screw
984736 Flange screw
1372, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A MP; D13C2-A MP; D13C3-A MP, D16C-A MG, D16C-A MH; D16C-
984727
 
984727 Flange screw
1372, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13B-J MP; D13B-M MP, D13C1-A MP; D13C2-A MP; D13C3-A MP, D16C-
990950
Flange lock nut
990950 Flange lock nut
1372, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A MP; D13C2-A MP; D13C3-A MP, D5A-T; D5A-TA; D5A-B TA, D8
984826
 
984826 Flange screw
1372, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A MP; D13C2-A MP; D13C3-A MP, D16C-A MG, D16C-A MH; D16C-
996061
 
996061 Flange screw
1372, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13C1-A MP; D13C2-A MP; D13C3-A MP, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D3-110I-H; D3-140A-H; D3-140I-H, D4-180I-F; D
Back to top