3583355 Volvo.Penta Flange


3583355 Flange Volvo.Penta 120S-A; 120S-B; 120S-D, 130S-C; 130SR-C, 130S; 130S-B; 130SR-A, 150S-C; 150SR-C, 150S; 150S-B; 150SR, D1-13; D1-13B; D1-20 Flange
3583355 Flange Volvo Penta
Rating:
8

Buy Flange 3583355 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 48
 

Volvo Penta entire parts catalog list:

120S-A; 120S-B; 120S-D; 120S-E; MS25S-A; MS25SR-A
130S-C; 130SR-C
130S; 130S-B; 130SR-A; 130SR-B
150S-C; 150SR-C
150S; 150S-B; 150SR; 150SR-B
D1-13; D1-13B; D1-20; D1-20B; D1-30; D1-30B; D2-40; D2-40B; D1-13F; D1-20F; D1-30F; D2-40F

Information:


Table 1
Diagnostic Trouble Codes
CDL Code Code Description
(code descriptions may vary) Comments
100-13 Engine Oil Pressure Sensor : Out of Calibration During key on, the signal voltage from the engine oil pressure sensor indicated an engine oil pressure greater than +/- 54 kPa (8 psi) from the atmospheric pressure sensor.
Reference sensor : Atmospheric Pressure Sensor
101-13 Crankcase Air Pressure Sensor : Out of Calibration During key on, the signal voltage from the crankcase air pressure sensor indicated a crankcase air pressure greater than +/- 1.5 kPa (0.2 psi).
There is not a reference sensor for this sensor
274-13 Atmospheric Pressure Sensor : Out of Calibration During key on, the signal voltage from the atmospheric pressure sensor indicated an atmospheric pressure other than 0 kPa (0 psi).
This sensor is used as a reference sensor
1785-13 Intake Manifold Pressure Sensor : Out of Calibration During key on, the signal voltage from the Intake Manifold pressure sensor indicated an Intake Manifold pressure greater than +/- 18 kPa (3 psi) from the Atmospheric Pressure sensor.
Reference sensor : Atmospheric Pressure Sensor
Table 2
Troubleshooting Test Steps Values Results
1. Check for Diagnostic Trouble Codes
The engine coolant temperature must be greater than 0° C (32° F) before beginning this procedure.
A. Establish communication between Cat® Electronic Technician (ET) and the Electronic Control Module (ECM) . Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Download the "Warranty Report" from the engine ECM before performing any troubleshooting or clearing diagnostic trouble codes.
C. Wait at least 30 seconds in order for the diagnostic codes to become active.
Look for an active -13 code or for a logged -13 code.
Diagnostic Trouble Codes
Result: There is an active or there is a logged -13 code.
Proceed to Test Step 2.
2. Check for Debris
A. Turn the keyswitch to the OFF position.
B. Check the suspect sensor for debris.
C. If applicable, check the reference sensor for debris.
D. Check the sensor measurement port for blockage by debris.
E. If debris is found, clear the debris from the measurement port and replace the suspect sensor.
F. Turn the keyswitch to the ON position.
G. Check for -13 codes. Wait at least 30 seconds in order for the diagnostic codes to become active.
Debris
Result: The sensor measurement port is not blocked by debris.
Proceed to Test Step 3.
Result: A -13 code is present, replace the suspect sensor. Verify that the problem is resolved.
Result: If more than one -13 code is present and the codes have a reference sensor, replace the reference sensor. Verify that the problem is resolved.
3. Inspect the Suspect Sensor Connector
A. Turn the keyswitch to the OFF position.
Inspect the suspect sensor connector for moisture and/or corrosion.
Moisture
Result: The suspect sensor connector has moisture and/or corrosion.
Proceed to Test Step 4.
Result: The suspect sensor connector does not have moisture and/or corrosion.
Proceed to Test Step 5.
4. Remove any moisture and/or corrosion
A. Disconnect the suspect sensor connector.
B. Remove any moisture and/or corrosion from the outside of the connector. Check for moisture and corrosion inside the connector. Verify that the seals for the wires are sealing correctly. Refer to Troubleshooting, "Electrical Connectors - Inspect", if necessary.
C. If necessary, repair the connector or replace the connector.
D. Reconnect the connector. Verify that the connection is secure.
E. Turn the keyswitch to the ON position.
F. Monitor the diagnostic codes on Cat ET. Check for -13 codes. Wait at least 30 seconds in order for the diagnostic codes to become active.
Moisture
Result: A -13 code is not present, return the unit to service.
Result: A -13 code is present, replace the suspect sensor. Verify that the problem is resolved.
Result: If more than one -13 code is present and the codes have a reference sensor, replace the reference sensor. Verify that the problem is resolved.
5. Check for Moisture and/or Corrosion in the Circuit
A. Check all of the connectors in the circuit for moisture and/or corrosion.
B. Check for corrosion inside the connector. Verify that the seals for the wires are sealing correctly. Refer to Troubleshooting, "Electrical Connectors - Inspect", if necessary.
C. If necessary, repair the connector or replace the connector.
D. Reconnect the connector. Verify that the connection is secure.
E. Turn the keyswitch to the ON position.
F. Monitor the diagnostic codes on Cat ET. Check for -13 codes. Wait at least 30 seconds in order for the diagnostic codes to become active.
Moisture
Result: A -13 code is not present, return the unit to service.
Result: A -13 code is present, repair or replace the wiring for the suspect sensor. Verify that the problem is resolved.
Result: If more than one -13 code is present and the codes have a reference sensor, replace the reference sensor. Verify that the problem is resolved.
Contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).


Parts flange Volvo Penta:

965185
 
965185 Flange screw
120S-A; 120S-B; 120S-D, 130S; 130S-B; 130SR-A, 150S; 150S-B; 150SR, 2001; 2001B; 2001AG, 8.1Gi-E; 8.1Gi-EF; 8.1GXi-D, 8.1Gi-F; 8.1Gi-FF; 8.1GXi-E, 8.1Gi-G; 8.1Gi-GF; 8.1GXi-F, 8.1Gi-H; 8.1Gi-HF; 8.1GXi-G, 8.1Gi-J; 8.1Gi-JF; 8.1OSi-J, 8.1GiC-400-J; 8.
945407
Flange nut
945407 Flange nut
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C
948645
Flange lock nut
948645 Flange lock nut
2001; 2001B; 2001AG, 4.3GLMMDA; 4.3GLPMDA; 4.3GSPMDA, 4.3GLPBYC; 4.3GSPBYC; 4.3GIPBYCCE, 4.3GLPHUB; 4.3GSPHUB; 4.3GSPHUS, 4.3GLPLKD; 4.3GLPLKE; 4.3GSPLKD, 4.3GLPNCA; 4.3GLPNCB; 4.3GLPNCS, 5.0FIPHUBCE; 5.0FIPHUCCE; 5.0FIPHUECE, 5.0FiPMDA; 5.0FiPMDM; 5
968476
 
968476 Flange screw
2001; 2001B; 2001AG, 8.1IPSCE-JF; 8.1IPSCE-MF, 8.1IPSCE-PF; 8.1IPSCE-Q; 8.1IPSCE-P, 8.1IPSE-JF, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D1-13; D1-13B; D1-20, D2-55; D2-55B; D2-55C, D2-75; D2-75B; D2-75C, D3-110I-A; D3
971098
Flange lock nut
971098 Flange lock nut
3.0GLM-C; 3.0GLP-C, 3.0GLP-A; 3.0GLP-B; 3.0GLM-A, 3.0GLP-D, 3.0GLP-E, 3.0GLP-J; 3.0GLP-N, 3.0GSPBYCCE; 3.0GSPEFS; 3.0GSMEFS, 3.0GXiC-J; 3.0GXi-J, 4.3GL-A; 4.3GL-B; 4.3GL-C, 4.3GL-E; 4.3GL-EF, 4.3GL-G; 4.3GL-GF, 4.3GL-J; 4.3GL-JF, 4.3GXi-C; 4.3GXi-CF;
21246409
 
21246409 Flange nut
D1-13; D1-13B; D1-20, D2-55; D2-55B; D2-55C, D2-75; D2-75B; D2-75C
990939
Flange nut
990939 Flange nut
1372, D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D1
984753
 
984753 Flange screw
1372, D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A MP; D13C2-A MP; D13C3-A MP, D16C-
Back to top