823378 Flange Volvo.Penta
MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A
Flange
Price: query
Rating:
Compatible models:
MD100A; TMD100A; TMD100AK
MD120A; MD120AK; TMD120A
Volvo.Penta
Volvo Penta entire parts catalog list:
MD120A; MD120AK; TMD120A; TMD120AK; TAMD120A; TAMD120AK; TMD120B; TAMD120B; TAMD120B-CC
Information:
Illustration 1 g01624718
Typical example
Illustration 2 g01321419
P1 ECM connector
(P1-34) J1939 data link −
(P1-42) J1939 shield
(P1-50) J1939 data link +
Illustration 3 g01624283
Terminal locations for the following connectors A-C92/F-C1/F-C2/G-C6 Connectors for a RH Control panel and C-C17/F-C1/F-C2/G-C6 Connectors for a LH Control panel
(Terminal 5) J1939 data link +
(Terminal 6) J1939 data link −
(Terminal 7) J1939 shield
Illustration 4 g01321422
C-C18/(TB-C1 customer or L-C1/L-C2 EMCP 3) connectors
(Terminal BT) J1939 shield
(Terminal BU) J1939 data link −
(Terminal BV) J1939 data link +
Illustration 5 g01624670
Service tool connector
(Terminal C) J1939 shield
(Terminal F) J1939 data link −
(Terminal G) J1939 data link +
Illustration 6 g01622856
Connector locations
(1) A-C1/E-C2/E-C1 Right hand cross over harness
(2) A-C2/J-C2/J-C1 Right hand cross over harness
(3) A-C90/P-C1 Connectors for the power distribution panel
(4) A-C91/P-C2 Connectors for the power distribution panel
(5) A-C60 Connector for the prelube motor
(6) A-C92/F-C1/F-C2/G-C6 Connectors for a RH Control panel
(7) C-C22 Primary ECM connector P2
(8) C-C15 Primary ECM connector P1
(9) C-C28 Secondary ECM connector P2
(10) C-C29 Secondary ECM connector P1
(11) C-C47 Connector for the power relay panel
(12) C-C17/F-C1/F-C2/G-C6 Connectors for a LH Control panel
(13) C-C18/(TB-C1 customer or L-C1/L-C2 EMCP 3) connectors
(14) C-C2/J-C1/J-C2 Left hand cross over harness
(15) C-C1/E-C1/E-C2 Left hand cross over harness Test Step 1. Inspect Electrical Connectors and Wiring
Remove power from the ECM.
Thoroughly inspect the J1/P1 ECM connector and the J2/P2 ECM connector. Inspect all of the connectors that are associated with the circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connectors that are associated with the circuit.
Check the allen head screw on each ECM connector for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.
Check the harness and wiring for abrasion and for pinch points. Expected Result:All connectors, pins and sockets are completely coupled and/or inserted. The harness and wiring are free of corrosion, of abrasion or of pinch points.Results:
OK - The harness and wiring appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem in the wiring harness.Repair: Perform the following repair:Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled. Refer to Troubleshooting, "Electrical Connectors - Inspect".Verify that the repair eliminates the problem.STOPTest Step 2. Verify the Proper Installation of the Data Link Circuit
Disconnect any module that is connected to the CAN data link.
Disconnect J1/P1 ECM connector and measure the resistance between P1-50 (CAN data link +) and P1-34 (CAN data link -). Expected Result:The resistance is between 57 and 63 Ohms.Results:
OK - The resistance is within the range. Proceed to Test Step 5.
Not OK - The range of the resistance is 114 Ohms to 126 Ohms. A terminating resistor is missing.Repair: Verify that two terminating resistors exist on the data link. One resistor must be located on each end of the data link.STOP
Not OK - Resistance is less than 57 Ohms. Proceed to Test Step 3.
Not OK - Resistance is greater than 126 Ohms. Proceed to Test Step 4.Test Step 3. Check for a Short Circuit
Remove the terminating resistors from the CAN data link.
Measure the resistance from the following pins to every pin on ECM connector P1 and to engine ground.
P1-50 (CAN data link +)
P1-34 (CAN data link -)Expected Result:Each resistance measurement indicates an open circuit.Results:
OK - There are no shorts. Proceed to Test Step 4.
Not OK - A short exists in the wiring harness.Repair: Make the necessary repairs.Verify that the repair eliminates the problem.STOPTest Step 4. Check for an Open Circuit
Make sure that all connections remain disconnected.
Fabricate a jumper wire. Use the jumper wire in order to short pin F to pin G on the service tool connector.
Measure the resistance between P1-50 (CAN data link +) and P1-34 (CAN data link -) at the ECM connector.
Remove the wire short. Expected Result:The resistance measurement indicates a short circuit.Results:
OK - There is not an open circuit. Proceed to Test Step 5.
Not OK - An open circuit exists in the wiring harness.Repair: Make the necessary repairs.Verify that the repair eliminates the problem.STOPTest Step 5. Check the Module on the CAN Data Link
Connect the module to another engine.
If the module operates properly on a different engine, there may be a problem with the ECM.
If the module does not function properly on the different engine, replace the module. Expected Result:The module operates properly.Results:
OK - The module operates properly on another engine.Repair: The problem may be intermittent. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - The module does not operate properly on another engine.Repair: Replace the module. Verify that the repair corrects the problem.STOP
Parts flange Volvo Penta:
834480
834480 Flange
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 4.3GXi-G; 4.3GXi-GF; 4.3OSi-G, 4.3GXi-J; 4.3GXi-JF; 4.3OSi-J, 4.3GXiE-225-R, 4.3GXiE-M, 4.3GXiE-P; 4.3GXiE-Q, 430; 430A; 430B, 5.0GXi-G; 5.0GXi-GF; 5.0OSi-G, 5.0GXi-J; 5.0GXi-JF; 5.0OSi-J, 5.0GXiCE-270-R;
469324
469324 Flange
AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, D70B; D70B PP; D70B K, D70CHC; D70CRC; TD70CHC, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAD
820915
820915 Flange
AQD70D; TAMD70D; TAMD70E, D120A; D120AK; TD120A, MD120A; MD120AK; TMD120A, TAMD60C, TAMD61A; TAMD62A, TAMD71A; TAMD72A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TMD102A; TAMD102A; TAMD102D
820905
820905 Flange
AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D42A; D42A PP, D70B; D70B PP; D70B K, D70CHC; D70CRC; TD70CHC, MD100A; TMD100A; TMD100AK, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAMD60A; TAMD60B, TAMD60C, TAMD61A; T
807625
807625 Flange
AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, MD100A; TMD100A; TMD100AK, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1030P, TAD12
422067
422067 Flange screw
D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, DH10A; DH10A 285; DH10A 360, MD100A; TMD100A; TMD100AK, TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1030P, TAMD103A, TD100CHC; TD100CRC; TD121CHC, TD100G-87; TD1030ME; TWD1030ME,
836328
836328 Flange
D100A; D100AK; D100B, D70B; D70B PP; D70B K, MD100A; TMD100A; TMD100AK, MD70B; MD70BK; TMD70B
944012
944012 Flange screw
AQ190A; AQ240A, D100A; D100AK; D100B, D120A; D120AK; TD120A, D70B; D70B PP; D70B K, MD120A; MD120AK; TMD120A, TD120C, TD120HPP; TID120HPP, TD60A; TD60B; TD60B PP, TD60D; TD60D-83; TD60DPP-83, TD70G; TD70G-83; TD70GPP, TID120FPP; TID120FG; TD120G