968854 Flange screw Volvo.Penta
230A; 230B; 250A
Flange
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$14.99
06-09-2024
CN: Garden Bowels
New Fresh 10pcs Rafflesia Plants Seeds Generic
Generic ✅ ABOUT PRODUCT- This package contains New Fresh Rafflesia Plants seeds Generic , SEEDS ONLY, no live plants.The photos show are the mature plant in the future, not the actual plant you will receive || ✅ PREMIUM TREE SEED MIXTURES -Premium Seed Mix is a blend of high quality ingredients and fertilisers designed specifically for germinating and growing from seeds with vigorous || ✅QUALITY - All seeds packaged by Seed Needs are intended for the current and the following growing seasons. All seeds are stored in a temperature controlled facility that is free of significant amounts of moisture. || ✅GERMINATION - Seed Needs packets contain some of the freshest seed available. Direct from the growers. If sown correctly, you will begin seeing results in only a matter of days || ✅ REACH US -If you do not satisfy with the products, please do not leave negative/neutral feedback. You can contact us for solution. We will try our best to fix the problem as soon as possible
Generic ✅ ABOUT PRODUCT- This package contains New Fresh Rafflesia Plants seeds Generic , SEEDS ONLY, no live plants.The photos show are the mature plant in the future, not the actual plant you will receive || ✅ PREMIUM TREE SEED MIXTURES -Premium Seed Mix is a blend of high quality ingredients and fertilisers designed specifically for germinating and growing from seeds with vigorous || ✅QUALITY - All seeds packaged by Seed Needs are intended for the current and the following growing seasons. All seeds are stored in a temperature controlled facility that is free of significant amounts of moisture. || ✅GERMINATION - Seed Needs packets contain some of the freshest seed available. Direct from the growers. If sown correctly, you will begin seeing results in only a matter of days || ✅ REACH US -If you do not satisfy with the products, please do not leave negative/neutral feedback. You can contact us for solution. We will try our best to fix the problem as soon as possible
Compatible models:
230A; 230B; 250A
Volvo.Penta
Volvo Penta entire parts catalog list:
Information:
Illustration 1 g00814279
Typical schematicTest Step 1. Check for Connector Damage.
Turn the circuit breaker for the battery to the OFF position.
Turn the keyswitch to the OFF position.
Disconnect the main power.
Thoroughly inspect the ECM connectors J1/P1 and J2/P2. Inspect all of the other connectors. Refer to Troubleshooting, "Inspecting Electrical Connectors" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque of 6.0 N m (55 lb in).
Check the customer connector (allen head screw) for the proper torque of 2.25 0.25 N m (20 2 lb in).
Check the harness and the wiring for abrasion and pinch points.Expected Result:The connectors and wiring should be free of the following problems: damage, corrosion, abrasion and incorrect attachment.Results:
OK - The connectors and the wiring are okay. Proceed to test step 2.
Not OK - The connectors and/or wiring need repair.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Stop.Test Step 2. Check the Status of the Ground Level Shutdown Switch on the ET.
Install the ET to the service tool connector.
Turn the keyswitch to the ON position. The engine should be off.
Monitor the status of the ground level shutdown switch on the ET with the switch in the RUN position.
Operate the ground level shutdown switch by changing the switch position to the SHUTDOWN position. Monitor the status for the ground level shutdown switch on the ET.Expected Result:The status of the ground level shutdown switch should read "OFF" when the ground level shutdown switch is in the RUN position. The status of the ground level shutdown switch should read "ON" with the ground level shutdown switch in the SHUTDOWN position.Results:
OK - The status of the ground level shutdown switch reads "ON" with the ground level shutdown switch in the SHUTDOWN position. The status of the ground level shutdown switch reads "OFF" when the ground level shutdown switch is in the RUN position.Repair: The circuit for the ground level shutdown switch is operating correctly. Stop.
Not OK - The status of the ground level shutdown switch does not read "OFF" when the ground level shutdown switch is in the RUN position. The status of the ground level switch does not read "ON" with the ground level shutdown switch in the SHUTDOWN position. The circuit for the ground level shutdown switch is not operating correctly. Proceed to test step 3.Test Step 3. Short the Ground Level Shutdown Switch at the ECM.
Disconnect the ECM connector J1/P1.
Remove wire F709-BU from P1-34 at ECM connector P1. Remove wire F708-YL from P1-28 at ECM connector P1. Remove wire 998-BR from P1-29 at ECM connector P1. Use a 151-6320 Wire Removal Tool .
Insert a jumper wire with socket terminals at each end into the connector P1 on pins P1-28 and P1-29.
Reconnect all the connectors.
Turn the keyswitch to the ON position. The engine should be off.Note: The digital return will no longer be connected to the other sensors and switches. Additional diagnostic codes will be generated from the ECM. Clear the codes after you complete this test.
Monitor the status of the ground level shutdown switch on the ET.
Turn the keyswitch to the OFF/RESET position.
Disconnect the ECM connector J1/P1.
Remove the wire short.
Insert a jumper wire with socket terminals at each end into the ECM connector P1 on pins P1-34 and P1-29.
Reconnect all of the connectors.
Turn the keyswitch to the ON position. The engine should be off.
Observe the status of the ground level shutdown switch on the ET.
Turn the keyswitch to the OFF/RESET position.
Remove the wire short and replace all wires.Expected Result:The status should read "OFF" when the wire short is inserted between pins P1-28 and P1-29. The status should read "ON" when the wire short is inserted between pins P1-34 and P1-29.Results:
OK - The status reads "OFF" when the wire short is inserted between pins P1-28 and P1-29. The status reads "ON" when the wire short is inserted between pins P1-34 and P1-29. The status is correct on the ET. Proceed to test step 4.
Not OK - The status does not read "OFF" when the wire short is inserted between pins P1-28 and P1-29. The status does not read "ON" when the wire short is inserted between pins P1-34 and P1-29. The status is incorrect on the ET.Repair: Replace the ECM. Refer to Troubleshooting, "Replacing the ECM". Stop.Test Step 4. Check for an Open Circuit in the Wires that go to the Engine Shutdown Switch.
Turn the keyswitch to the OFF/RESET position.
Disconnect ECM connector J1/P1.
Install a jumper wire at the engine shutdown switch between wire F708-YL on terminal 3 and wire F709-BU on terminal 1.
Measure the
Parts flange Volvo Penta:
945407
945407 Flange nut
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C
945444
945444 Flange screw
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 4.3GL-E; 4.3GL-EF, 4.3GLMMDA; 4.3GLPMDA; 4.3GSPMDA, 4.3GLPBYC; 4.3GSPBYC; 4.3GIPBYCCE, 4.3GLPHUB; 4.3GSPHUB; 4.3GSPHUS, 4.3GLPLKD; 4.3GLPLKE; 4.3GSPLKD, 4.3GLPNCA; 4.3GLPNCB; 4.3GLPNCS, 4.3GXi-B; 4.3GXi-BF
965175
965175 Flange screw
2001; 2001B; 2001AG, 230A; 230B; 250A, 3.0GSPBYCCE; 3.0GSPEFS; 3.0GSMEFS, 3.0GXiC-J; 3.0GXi-J, 4.3GLPEFS; 4.3GiPEFS, 430; 430A; 430B, 5.0GLPEFS; 5.0GiPEFS; 5.7GSPEFS, 5.0GXi-270-R, 5.0GXi-P, 5.0GXiC-270-R; 5.0GiC-225-S, 5.0GXiC-J; 5.0GXiC-JF; 5.0GiC-
834480
834480 Flange
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 4.3GXi-G; 4.3GXi-GF; 4.3OSi-G, 4.3GXi-J; 4.3GXi-JF; 4.3OSi-J, 4.3GXiE-225-R, 4.3GXiE-M, 4.3GXiE-P; 4.3GXiE-Q, 430; 430A; 430B, 5.0GXi-G; 5.0GXi-GF; 5.0OSi-G, 5.0GXi-J; 5.0GXi-JF; 5.0OSi-J, 5.0GXiCE-270-R;
827265
827265 Flange
230A; 230B; 250A, 251A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B
968458
968458 Flange cap nut
230A; 230B; 250A, 251A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ131A; AQ131B; AQ131C, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, KAD32P; TAMD42WJ-A; KAD43P-A, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, KAD42P-A;
966862
966862 Flange screw
230A; 230B; 250A, AQ131A; AQ131B; AQ131C, TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1030P, TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TAD1630P; TWD1630P; TWD1630PP, TAD1630V; TWD1630V, TAMD162C-C; TAMD163A-A;
856297
856297 Flange
230A; 230B; 250A, 251A, AQ131A; AQ131B; AQ131C, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C