985030 Volvo.Penta Flange screw


985030 Flange screw Volvo.Penta MD2010-C; MD2010-D; MD2020-C, MD2010A; MD2020A; MD2030A, MD2010B; MD2020B; MD2030B Flange
985030 Flange screw Volvo Penta
Rating:
43

Buy Flange screw 985030 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
 
$98.00
 

29-08-2017

Axis - MVP: Axis - MVP Group
Axis - MVP Group 985030 MAIN BOARD FX44
MAIN BOARD FX44
 
$98.00
 

29-08-2017

Hydra Kool: Hydra Kool - MVP
Hydra Kool - MVP 985030 MAIN BOARD FX44
MAIN BOARD FX44
 
$98.00
 

29-08-2017

Jet Tech -: Jet Tech - MVP Group
Jet Tech - MVP Group 985030 MAIN BOARD FX44
MAIN BOARD FX44
Number on catalog scheme: 6
 

Volvo Penta entire parts catalog list:

MD2010-C; MD2010-D; MD2020-C; MD2020-D; MD2030-C; MD2030-D; MD2040-C; MD2040-D; 120S-D; 120S-E
MD2010A; MD2020A; MD2030A; MD2040A; MS2B-R; MS2A-D; MS2A-E; MS2L-D; MS2L-E; 120S-D; 120S-E; MD2010; MD2030; MD2040; MD2020
MD2010B; MD2020B; MD2030B; MD2040B; MS2L-D; MS2A-D; 120S-D; MS2B-R; MS2A-E; MS2L-E

Information:


Use of commercially available cooling system cleaners may cause damage to cooling system components. Use only cooling system cleaners that are approved for Caterpillar engines.
Note: Inspect the water pump and the water temperature regulator after the cooling system has been drained. This is a good opportunity to replace the water pump, the water temperature regulator, and the hoses, if necessary. Drain
Pressurized System: Hot coolant can cause serious burns. To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pressure.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap.
Open the cooling system drain valve (if equipped). If the cooling system is not equipped with a drain valve, remove one of the drain plugs. Note: If equipped, be sure to drain the heater and any related supply and return lines.Allow the coolant to drain.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
For information regarding the disposal and the recycling of used coolant, consult your Cat dealer or consult Caterpillar Dealer Service Tool Group:Outside Illinois 1-800-542-TOOL
Inside Illinois 1-800-541-TOOL
Canada 1-800-523-TOOL
Flush
Flush the cooling system with clean water in order to remove any debris.
Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to the Specifications Manual, SENR3130, "Torque Specifications" for more information on the proper torques.
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the cooling system filler cap.
Start and run the engine at low idle for a minimum of 30 minutes. The coolant temperature should be at least 82 °C (180 °F).
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. If equipped, be sure to flush the heater and any related supply and return lines. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to the Specifications Manual, SENR3130, "Torque Specifications" for more information on the proper torques. Cooling Systems with Heavy Deposits or Plugging
Note: For the following procedure to be effective, there must be some active flow through the cooling system components.
Flush the cooling system with clean water in order to remove any debris. Note: If equipped, be sure to flush the heater and any related supply and return lines.
Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to the Specifications Manual, SENR3130, "Torque Specifications" for more information on the proper torques.
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 3.8 to 7.6 L (1 to 2 US gal) of the cooling system capacity. Install the cooling system filler cap.
Start and run the engine at low idle for a minimum of 90 minutes. The coolant temperature should be at least 82 °C (180 °F).
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to the Specifications Manual, SENR3130, "Torque Specifications" for more information on the proper torques. Fill
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Fill the cooling system with coolant/antifreeze. Refer to the Operation and Maintenance Manual, "Refill Capacities" and this Operation and Maintenance Manual, "Fluid Recommendations" topic for more information on cooling system specifications. Do not install the cooling system filler cap.
Start and run the engine at low idle. Increase the engine rpm to 1500 rpm. Run the engine at high idle for 1 minute in order to purge the air from the cavities of the engine block. Stop the engine.
Check the coolant level. Maintain the coolant level within 13 mm (0.5 inch) below the bottom of the pipe for filling. Maintain the coolant level within 13 mm (0.5 inch) to the proper level on the sight glass (if equipped).
Clean the cooling system filler cap. Inspect the gasket that is on the cooling system filler cap. If the gasket that is on the cooling system filler cap is damaged, dis


Parts flange Volvo Penta:

946934
 
946934 Flange screw
251A, 3.0GXiC-J; 3.0GXi-J, 4.3GXi-B; 4.3GXi-BF; 4.3OSi-B, 430; 430A; 430B, 5.0GXi-B; 5.0GXi-BF; 5.0OSi-B, 5.0GXiC-J; 5.0GXiC-JF; 5.0GiC-J, 5.7GiC-300-J; 5.7GiC-300-JF; 5.7GXiC-J, 740A; BB740A, 8.1Gi-J; 8.1Gi-JF; 8.1OSi-J, 8.1GiC-400-J; 8.1GiC-400-JF;
965184
 
965184 Flange screw
2001; 2001B; 2001AG, 230A; 230B; 250A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, D5A-T; D5A-TA; D5
945407
Flange nut
945407 Flange nut
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C
948645
Flange lock nut
948645 Flange lock nut
2001; 2001B; 2001AG, 4.3GLMMDA; 4.3GLPMDA; 4.3GSPMDA, 4.3GLPBYC; 4.3GSPBYC; 4.3GIPBYCCE, 4.3GLPHUB; 4.3GSPHUB; 4.3GSPHUS, 4.3GLPLKD; 4.3GLPLKE; 4.3GSPLKD, 4.3GLPNCA; 4.3GLPNCB; 4.3GLPNCS, 5.0FIPHUBCE; 5.0FIPHUCCE; 5.0FIPHUECE, 5.0FiPMDA; 5.0FiPMDM; 5
949874
Flange lock nut
949874 Flange lock nut
2001; 2001B; 2001AG, 3.0GLM-C; 3.0GLP-C, 3.0GLP-A; 3.0GLP-B; 3.0GLM-A, 3.0GLP-D, 3.0GLP-E, 3.0GLP-J; 3.0GLP-N, 3.0GXiC-J; 3.0GXi-J, 4.3GL-A; 4.3GL-B; 4.3GL-C, 4.3GL-E; 4.3GL-EF, 4.3GL-G; 4.3GL-GF, 4.3GL-J; 4.3GL-JF, 4.3GL-P, 4.3GXi-225-R; 4.3Gi-200-R
946441
Flange screw
946441 Flange screw
2001; 2001B; 2001AG, 230A; 230B; 250A, 8.1Gi-A; 8.1Gi-B; 8.1Gi-BF, 8.1Gi-E; 8.1Gi-EF; 8.1GXi-D, 8.1Gi-F; 8.1Gi-FF; 8.1GXi-E, 8.1Gi-G; 8.1Gi-GF; 8.1GXi-F, 8.1Gi-H; 8.1Gi-HF; 8.1GXi-G, 8.1Gi-J; 8.1Gi-JF; 8.1OSi-J, 8.1GiC-400-J; 8.1GiC-400-JF; 8.1GiC-40
948217
 
948217 Flange screw
251A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D2-55; D2-55B; D2-55C, D3-110I-A; D3-110I-B; D3-110I-C, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-22
965183
 
965183 Flange screw
AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, D12D-A MG; D12D-E MG, D12D-A MH; D12D-B MH; D12D-C MH, D2-75; D2-75B; D2-75C, D4-180I-B; D4-180I-C; D4-180I-D, D4-180I-F; D4-225A-F; D4-225I-F, DH10A; DH10A 285; DH10A 360, IPS-
Back to top