Information:

this procedure if the engine shuts down immediately after starting.Note: The engine must be equipped with an electric starting motor.Test Step 1. Inspect Electrical Connectors and Wiring
Turn the main disconnect switch to the OFF position.
Thoroughly inspect all of the connectors that are associated with the circuit.Expected Result:All connectors, pins and sockets are completely coupled and/or inserted and the harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The harness and connectors appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem with the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled.Verify that the repair eliminates the problem.STOPTest Step 2. Start the Engine
Turn the main disconnect switch to the ON position and start the engine. View the engine "Status Control Module (SCM)".Expected Result:The engine is running. There were no active fault indicators.Results:
OK - The engine is running. There were no active fault indicators.Repair: The problem is no longer present. If the problem is intermittent, inspect the electrical connectors and wiring.If necessary, repair the connectors or wiring and/or replace the connectors or wiring.Verify that the repair eliminates the problem.STOP
Not OK - The engine does not crank. The SCM shows a blank screen, regardless of the position of the "Engine Control Switch (ECS)". Proceed to Test Step 3.
Not OK - The engine does not crank. All of the fault indicators are illuminated.Repair: Proceed to Troubleshooting, "Engine Shutdown Unexpected and All Fault Indicators Are Flashing".STOP
Not OK - The engine does not crank. A fault indicator(s) is illuminated.Repair: Proceed to the appropriate diagnostic procedure in Troubleshooting.STOP
Not OK - The engine does not crank. There are no fault indicators. Allow the "CB2" to cool down for five minutes. Proceed to Test Step 4.Test Step 3. Check the Voltage at the SCM
Turn the ECS to the STOP position.
Measure the voltage between terminal 1 and terminal F at the SCM.Note: Place the positive meter lead on terminal F and place the negative meter lead on terminal 1.Expected Result:The voltage should be between 15 VDC and 45 VDC. The polarity is correct.Results:
OK - The voltage is between 15 VDC and 45 VDC.Repair: Replace the SCM.STOP
NOT OK - The voltage is below 15 VDC. The polarity is correct.Repair: Measure the voltage at the battery posts. Check the wiring and/or connectors between the SCM and the battery.Repair the connectors or wiring and/or replace the connectors or wiring. Replace the battery, if necessary.Verify that the repair eliminates the problem.STOP
NOT OK - The polarity is not correct. Correct any improper connections in the wiring. Proceed to Test Step 4.Test Step 4. View the Battery Voltage Displayed on the SCM
View the battery voltage displayed on the SCM.Expected Result:The voltage is above 20 VDC.Results:
OK - The voltage is above 20 VDC. Proceed to Test Step 5.
NOT OK - The voltage is less than 20 VDC.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Replace the battery, if necessary.Verify that the repair eliminates the problem.STOPTest Step 5. Check the Starting Circuit
Momentarily connect a wire between terminal 25 and the +Battery terminal at the SCM.Expected Result:The engine cranks.Results:
OK - The engine cranks. Proceed to Test Step 6.
NOT OK - The engine does not crank.Repair: Proceed to Testing and Adjusting, "Starting Motor Magnetic Switch - Test".Troubleshoot the pinion solenoid and troubleshoot the starting motor. If necessary, repair components or replace components.Verify that the repair eliminates the problem.STOPTest Step 6. Check the Voltage at the SCM
Turn the ECS to the MANUAL/START position.
Measure the voltage between terminal 25 and the −Battery at the SCM.
Measure the voltage between terminal W and the −Battery at the SCM.
Measure the voltage between the +Battery and the −Battery at the SCM.Expected Result:The +Battery voltage is greater than 20 VDC.Results:
OK - The +Battery voltage is greater than 20 VDC.Repair: The problem is no longer present. If the problem is intermittent, inspect the electrical connectors and wiring.STOP
NOT OK - The +Battery voltage checks are all less than 20 VDC.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. If necessary, replace the battery.Verify that the repair eliminates the problem.STOP
NOT OK - The +Battery voltage is less than 20 VDC on terminal 25.Repair: Troubleshoot the starting motor relay. Proceed to Testing and Adjusting, "Relay Module - Test".STOP
NOT OK - The +Battery voltage is less than 20 VDC on terminal 25. The +Battery voltage is less than 20 VDC on terminal W. The +Battery voltage is greater than 20 VDC.Repair: Check the F8 fuse.Check the connectors or wiring. If necessary, replace parts or repair parts.Verify that the repair eliminates the problem.STOP


Parts flywheel Volvo Penta:

846348
 
846348 Flywheel housing
D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, TD120AHC; TD120ARC; TAD120AHC, TD120C, TD120HPP; TID120HPP, TID120FPP; TID120FG; TD120G, TMD100C
7742140_002
 
7742140_002 flywheel housing
D100A; D100AK; D100B
821791
Flywheel housing
821791 Flywheel housing
D100A; D100AK; D100B, D120A; D120AK; TD120A, TD120C, TID120FPP; TID120FG; TD120G
821244
 
821244 Flywheel housing
D100A; D100AK; D100B, TD100G-87; TD1030ME; TWD1030ME, TD100G; TD100G-85; TD100G-87
467523
Flywheel housing
467523 Flywheel housing
D100A; D100AK; D100B
823212
 
823212 Flywheel
D100A; D100AK; D100B
422023
Flywheel
422023 Flywheel
D100A; D100AK; D100B
846700
 
846700 Flywheel
D100A; D100AK; D100B, TD100G-87; TD1030ME; TWD1030ME, TD100G; TD100G-85; TD100G-87
Back to top