957178 Volvo.Penta Gasket


957178 Gasket Volvo.Penta 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ145A; BB145A, AQ175A, AQ190A; AQ240A, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ2 Gasket
957178 Gasket Volvo Penta
Rating:
63

Buy Gasket 957178 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 19
 

Compatible models:

2001; 2001B; 2001AG   230A; 230B; 250A   251A   AD30A; AQAD30A; MD30A   AD31D; AD31D-A; AD31XD   AD41D; D41D; TAMD41D   AQ115A; AQ115B; AQ130   AQ120B; AQ125A; AQ140A   AQ145A; BB145A   AQ175A   AQ190A; AQ240A   AQ200D; AQ200F; 280B   AQ225D; AQ225E; AQ225F   AQ260A; AQ260B; BB260A   AQ290A   AQD70D; TAMD70D; TAMD70E   D100A; D100AK; D100B   D100BHC; D100BRC; TD100AHC   D120A; D120AK; TD120A   D12D-A MG; D12D-E MG   D12D-A MH; D12D-B MH; D12D-C MH   D2-55; D2-55B; D2-55C   D2-75; D2-75B; D2-75C   D42A; D42A PP   D5A-T; D5A-TA; D5A-B TA   D70B; D70B PP; D70B K   D70CHC; D70CRC; TD70CHC   DH10A; DH10A 285; DH10A 360   KAD42A; KAMD42A; HS1A   KAD42B; KAMD42B; TAMD42B   KAD42P-A; KAMD42P-A; HS1A   MB10A   MD100A; TMD100A; TMD100AK   MD11; MD11C; MD11D   MD120A; MD120AK; TMD120A   MD1B; MD2B; AQD2B   MD2010-C; MD2010-D; MD2020-C   MD2010A; MD2020A; MD2030A   MD2010B; MD2020B; MD2030B   MD21B; AQD21B   MD22A; MD22A-A; MD22L-A   MD22L; MD22P; MD22L-B   MD31A; TMD31A; TMD31B   MD31A; TMD31B; TAMD31B   MD40A; TMD40A; TMD40B   MD5A; MD5B; MD5C   MD6; MD6A; MD6B   MD70B; MD70BK; TMD70B   MD70C; TMD70C; TAMD70C   TAD1030G; TD1010G; TWD1010G   TAD1630P; TWD1630P; TWD1630PP   TAD1630V; TWD1630V   TAD520GE; TAD720GE; TAD721GE   TAMD103A   TAMD122A; TMD122A; TAMD122P-A   TAMD162A; TAMD162B; TAMD162C   TAMD162C-C; TAMD163A-A; TAMD163P-A   TAMD165A; TAMD165C; TAMD165P   TAMD60A; TAMD60B   TAMD60C   TAMD71B; TAMD73P-A; TAMD73WJ-A   TAMD74A; TAMD74A-A; TAMD74A-B   TD100CHC; TD100CRC; TD121CHC   TD100G; TD100G-85; TD100G-87   TD120AHC; TD120ARC; TAD120AHC   TD120C   TD120HPP; TID120HPP   TD164KAE   TD520GE; TAD530GE; TAD531GE   TD60A; TD60B; TD60B PP   TD60D; TD60D-83; TD60DPP-83   TD70G; TD70G-83; TD70GPP   TID120FPP; TID120FG; TD120G   TID121FG   TID162AG; TID162AGP; TID162AP   TMD102A; TAMD102A; TAMD102D   TMD121C; TAMD121C; TAMD121D   TMD41A; TMD41B; D41A   TMD41B; D41B; TAMD41B   TWD1620G; TWD1630G; TAD1630G   Volvo.Penta

Volvo Penta entire parts catalog list:

2001; 2001B; 2001AG; 2001BG; 2002; 2002B; 2002D; 2002AG; 2002BG; 2003; 2003B; 2003D; 2003AG; 2003BG; 2003T; 2003TB; 2003 SOLAS; 2003B SOLAS; 2003T
230A; 230B; 250A; 250B
251A
AD30A; AQAD30A; MD30A; TAMD30A; TMD30A; AD30; AQAD30; MD30; TAMD30; TMD30
AD31D; AD31D-A; AD31XD; TAMD31D; TMD31D
AD41D; D41D; TAMD41D; TMD41D; HS1A
AQ115A; AQ115B; AQ130; AQ130A; AQ130B; AQ130C; AQ130D; AQ165A; AQ170A; AQ170B; AQ170C; AQD21A; BB115A; BB115B; BB115C; BB165A; BB170A; BB170B; BB1
AQ120B; AQ125A; AQ140A; BB140A
AQ145A; BB145A
AQ175A
AQ190A; AQ240A

Information:

Polarity is negative ground or insulated.Circuit ... A(1) Cutout relay: Air gap between armature and core ... .017 in.(0.43 mm)Point gap ... .032 in.(0.81 mm)Voltage closing range ... 22.8 to 25.2 V(2) Current regulator: Air gap between armature and core ... .068 to .082 in.(1.73 to 2.08 mm)Current setting range ... 14 to 16 A(3) Voltage regulator: Air gap between armature and core ... .067 in.(1.70 mm)Point gap ... .016 in.(0.41 mm)Voltage setting range at 85° F (29° C): Upper contacts ... 27.4 to 29.4 VLower contacts ... .2 to .6V less than upper contacts(4) Torque for bolt ... 36 6 lb. in.(4.1 0.7 N m)4M9349 24V 20A (Delco-Remy Number 1119653)
Polarity is negative ground or insulated.Circuit ... A(1) Cutout relay: Air gap between armature and core ... .015 to .019 in.(0.38 to 0.48 mm)Point gap ... .032 in.(0.81 mm)Voltage closing range ... 22.8 to 25.2 V(2) Current regulator: Air gap between armature and core ... .068 to .082 in.(1.73 to 2.08 mm)Current setting range ... 19 to 21 A(3) Voltage regulator: Air gap between armature and core ... .067 in.(1.70 mm)Point gap ... .016 in.(0.41 mm)Voltage setting range at 85° F (29° C): Upper contacts ... 27.4 to 29.4 VLower contacts ... .2 to .6V less than upper contacts.(4) Torque for bolt ... 36 6 lb. in.(4.1 0.7 N m)3S5028 24V 25A (Delco-Remy Number 1119306 and 1119306-E)
Polarity is negative ground.Circuit ... A(1) Cutout relay: Air gap between armature and core ... .015 to .019 in.(0.38 to 0.48 mm)Point gap ... .032 in.(0.81 mm)Voltage closing range ... 24 to 27 V(2) Current regulator: Air gap between armature and core ... .068 to .082 in.(1.73 to 2.08 mm)Current setting range ... 23 to 27 A(3) Voltage regulator: Air gap between armature and core ... .060 in.(1.52 mm)Voltage setting range at 85° F (29° C) ... 27.5 to 29.5 V(4) Torque for bolts ... 36 6 lb. in.(4.1 0.7 N m)3A1874 24 V (Paris-Rhone Number 2T216)
(1) Cutout relay: Air gap between armature and core ... .027 in.(0.69 mm)Point gap ... .031 in.(0.79 mm)Closing range when cold ... 24.0 to 26.0 V(2) Current regulator: Air gap between armature and core ... .039 in.(0.99 mm)Current setting range ... 14 to 15 A(3) Voltage regulator: Air gap between armature and core ... .043 in.(1.09 mm)Voltage setting range at 85° F (29° C) ... 26.8 to 28.2 V(4) Torque for bolts ... 36 6 lb. in.(4.1 0.7 N m)5A3061 (Mitsubishi Number RW-3B)
Cutout relay: Air gap between armature and core ... .043 to .055 in.(1.09 to 1.40 mm)Back gap ... .030 to .047 in.(0.76 to 1.19 mm)Point gap ... .020 to .032 in.(0.51 to 0.81 mm)Switch in ... 24.5 1 VReverse current (less than) ... 7 AVoltage regulator: Air gap between armature and core ... .039 to .047 in.(0.99 to 1.19 mm)Back gap ... .029 to 0.43 in.(0.74 to 1.09 mm)Regulator setting (no load) at 3000 rpm ... 27.5 to 29.5 VCurrent regulator: Air gap between armature and core ... .047 to .055 in.(1.19 to 1.40 mm)Back gap ... .029 to .043 in.(0.74 to 1.09 mm)Current limiter setting range at 3000 rpm ... 14 to 16 A5A7385 (Mitsubishi Number RT4342E)
Cutout relay: Air gap between armature and core ... .051 in.(1.30 mm)Point gap ... .016 to .024 in.(0.41 to 0.61 mm)Switch in ... 26 to 27 VReverse current (less than) ... 10 AVoltage regulator: Air gap between armature and core ... .079 to .087 in.(2.01 to 2.21 mm)Regulator setting (no load) at 3000 rpm ... 28 to 29 VCurrent regulator: Air gap between armature and core ... .051 to .069 in.(1.30 to 1.75 mm)Current limiter setting range at 4000 rpm ... 24 to 26 A


Parts gasket Volvo Penta:

947620
Gasket
947620 Gasket
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQD70D; TAMD70D; TAMD70E, D1-13; D1-13B; D1-20, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, D12D-A MG; D
969011
Gasket
969011 Gasket
1372, 2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ125B, AQ131A; AQ131B; AQ131C, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, D1-13; D1-13B; D1-20, D11A-A; D11A-B; D11A-C,
957173
Gasket
957173 Gasket
2001; 2001B; 2001AG, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ145A; BB145A, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A, AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD12
829487
Gasket
829487 Gasket
AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, KAD32P; TAMD42WJ-A; KAD43P-A, KAD42A; KAMD42A; HS1A, KAD42B; KAMD42B; TAMD42B, KAD42P-A; KAMD42P-A; HS1A, MD31A; TMD31A; TMD31B, MD31A; TMD31B; TAMD31B, M
947282
Gasket
947282 Gasket
AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQD70D; TAMD70D; TAMD70E, D11A-A; D11A-B; D11A-C, D11B1-A MP; D11B2-A MP, D11B3-A MP; D11B4-A MP, D2-55; D2-55B; D2-55C, D2-75; D2-75B; D2-75C, D3-110I-A;
833598
Gasket
833598 Gasket
MD11; MD11C; MD11D, MD1B; MD2B; AQD2B
1378864
Gasket
1378864 Gasket
230A; 230B; 250A, 251A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C
824677
Gasket
824677 Gasket
230A; 230B; 250A, 251A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C
Back to top