22227298 Volvo.Penta Gear housing, complete


22227298 Gear housing, complete Volvo.Penta SX-A; DPS-A; DPS-B Gear
22227298 Gear housing, complete Volvo Penta
Rating:
48

Buy Gear housing, complete 22227298 Volvo Penta genuine, new aftermarket parts with delivery
Number on catalog scheme: 2
 

Compatible models:

SX-A; DPS-A; DPS-B   Volvo.Penta

Volvo Penta entire parts catalog list:

SX-A; DPS-A; DPS-B; DPS-B1; DPS-A OXi; DPS-B OX; DPS-B1 OX; FWD; SX-A 1.43; SX-A 1.51; SX-A 1.60; SX-A 1.66; SX-A 1.79; SX-A 1.89; SX-A 1.97; S

Information:


Table 1
Default    Minimum    Maximum    
8 km/h (5 mph)    
0 km/h (0 mph)    
204 km/h (127 mph)    "Aftertreatment Regeneration Disable Switch Configuration"
This parameter identifies the Engine Control Module (ECM) connection for the "Aftertreatment Regeneration Disable Switch".
Table 2
Default    Alternatives    
Not Programmed     J1/P1-6, 7, 22, 23, 45, 40, 44, 45, 46, 47, 56, 58, 59, 60
J1939 Body Controller
J1939 Cab Controller
J1939 Instrument Cluster    "Aftertreatment Regeneration Force Switch Configuration"
This parameter identifies the ECM connection for the "Aftertreatment Regeneration Force Switch".
Table 3
Default    Alternatives    
Not Programmed     J1/P1-6, 7, 22, 23, 45, 40, 44, 45, 46, 47, 56, 58, 59, 60
J1939 Body Controller
J1939 Cab Controller
J1939 Instrument Cluster    "Diesel Particulate Filter Lamp Configuration"
This parameter identifies the ECM connection for the "Diesel Particulate Filter Lamp".
Table 4
Default    Alternatives    Output    
J1/P1:31     J1/P1: 10, 11, 12, 13, 19, 20     High Side Driver    
J1/P1: 29, 30, 31 Low Side Driver    "Diesel Particulate Filter Lamp Vehicle Speed Threshold"
The "Diesel Particluate Filter Lamp" and the "High Exhaust Temperature Lamp" are illuminated when the vehicle speed falls below the value of this parameter.Add additional paras for detailed operation.
Table 5
Default    Minimum    Maximum    
32 km/h (20 mph)    
32 km/h (20 mph)    
204 km/h (127 mph)    "High Exhaust System Temperature Lamp Configuration"
This parameter identifies the ECM connection for the "High Exhaust System Temperature Lamp".
Table 6
Default    Alternatives    Output    
J1/P1:30     J1/P1: 10, 11, 12, 13, 19, 20     High Side Driver    
J1/P1: 29, 30, 31 Low Side Driver    "High Exhaust System Temperature Lamp Diesel Particulate Filter Outlet Temperature Threshold"
The "High Exhaust System Temperature Lamp" is illuminated whenever the outlet temperature of the diesel particulate filter exceeds the value of this parameter.
Table 7
Default    Minimum    Maximum    
400 °C (752 °F)    
400 °C (752 °F)    
750 °C (1382 °F)    "High Exhaust System Temperature Lamp Strategy"
This parameter defines the operation of the "High Exhaust System Temperature Lamp"."Diesel Particulate Filter Outlet Temperature" - The "High Exhaust System Temperature Lamp" is illuminated whenever the outlet temperature of the particulate filter exceeds the value of the "High Exhaust System Temperature Lamp Diesel Particulate Filter Outlet Temperature Threshold" parameter."Regeneration Only" - The "High Exhaust System Temperature Lamp" is illuminated only during an active regeneration.
Table 8
Default    Alternative    
Diesel Particulate Filter Outlet Temperature     Regeneration Only    "Aftertreatment Regeneration Device Fan Enable Vehicle Speed Threshold"
The cooling fan will operate when the vehicle speed goes below the value of this parameter and an active regeneration is occurring.Note: The ECM must control the cooling fan in order for this parameter to affect the operation of the cooling fan.
Table 9
Default    Minimum    Maximum    
32 km/h (20 mph)    
32 km/h (20 mph)    
204 km/h (127 mph)    "Aftertreatment Regeneration Device Stationary Regeneration Strategy"
This parameter allows the operator to force an active regeneration when the vehicle's speed is zero.Disabled - The operator cannot force an active regeneration when the vehicle's speed is zero. However, an active regeneration can be forced via the Caterpillar Electronic Technician (ET).Enabled - The operator can force an active regeneration when the vehicle's speed is zero.
Table 10
Default    Alternative    
Disabled     Enabled    "Aftertreatment Regeneration Device Programmable Regeneration Monitoring System"
This parameter determines the level of action that is taken by the ECM if there is a possible problem with the particulate filter.


Parts gear Volvo Penta:

21658888
 
21658888 Gear housing, complete
D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H, SX-A; DPS-A; DPS-B
21658892
 
21658892 Gear housing, complete
D3-110I-G; D3-140A-G; D3-140I-G, D3-110I-H; D3-140A-H; D3-140I-H, SX-A; DPS-A; DPS-B
21120518
Gear housing
21120518 Gear housing
SX-A; DPS-A; DPS-B
21747724
 
21747724 Gear housing kit
SX-A; DPS-A; DPS-B
3842607
 
3842607 Gear housing
SX-A; DPS-A; DPS-B
3860904
 
3860904 Gear set
SX-A; DPS-A; DPS-B, XDP-B; TSK X-B; TSK X-BLT
3883621
 
3883621 Gear set
SX-A; DPS-A; DPS-B
3883622
 
3883622 Gear set
SX-A; DPS-A; DPS-B
Back to top