Information:
Table 1
J1939 Code and Description CDL Code and Description Comments
1761-1
Aftertreatment #1 DEF Tank Level : Low - most severe (3) E954 (3)
Low Aftertreatment #1 DEF Tank #1 Level The Electronic Control Module (ECM) detects that the remote Diesel Exhaust Fluid (DEF) tank level is lower than a threshold.
The code is logged.
1761-17
Aftertreatment #1 DEF Tank Level : Low - least severe (1) E954 (1)
Low Aftertreatment #1 DEF Tank #1 Level The ECM detects that the remote DEF tank level is lower than a threshold.
The code is logged.
1761-18
Aftertreatment #1 DEF Tank Level : Low - moderate severity (2) E954 (2)
Low Aftertreatment #1 DEF Tank #1 Level The ECM detects that the remote DEF tank level is lower than a threshold.
The code is logged.
4367-1
Aftertreatment #1 DEF Tank #2 Level : Low - most severe (3) E955 (3)
Low Aftertreatment #1 DEF Tank #2 Level The ECM detects that the DEF buffer tank level is below a threshold.
The code is logged.
4367-7
Aftertreatment #1 DEF Quick Thaw Tank Volume : Not Responding Properly E1589 (1)
Aftertreatment #1 DEF Tank Refill Not Responding to Command The ECM detects that the DEF buffer tank level is not refilling as fast as expected
The code is logged.
If the 4367–7 is active, the fill solenoid will be disabled until cleared.
4367-17
Aftertreatment #1 DEF Tank #2 Level : Low - least severe (1) E955 (1)
Low Aftertreatment #1 DEF Tank #2 Level The ECM detects that the DEF buffer tank level is below a threshold.
The code is logged.
4367-18
Aftertreatment #1 DEF Tank #2 Level : Low - moderate severity (2) E955 (2)
Low Aftertreatment #1 DEF Tank #2 Level The ECM detects that the DEF buffer tank level is below a threshold.
The code is logged.
4367-31
Aftertreatment #1 DEF Tank #2 Level E1589 (2)
Low Aftertreatment #1 DEF Tank #2 Level The ECM detects that the DEF buffer tank level is not refilling as fast as expected.
The code is logged.
If the 4367-31 code is active, the fill solenoid will be disabled until cleared.
Table 2
Associated Codes
J1939 Code CDL Code Troubleshooting Procedure
4367-3 3131-3 Troubleshooting, "DEF Tank Sensor - Test"
4367-4 3131-4 Troubleshooting, "DEF Tank Sensor - Test"
5434-3 N/A Troubleshooting, "Solenoid Valve - Test"
5434-4 N/A Troubleshooting, "Solenoid Valve - Test"
Illustration 1 g03738409
(1) Remote tank
(2) DEF tank refill valve
(3) Buffer tank
(4) DEF transfer pump (optional)
(5) DEF filter
Illustration 2 g06096192
(6) DEF filterProbable Causes
DEF level
Sensor
DEF lines
DEF filter
Transfer pump (if equipped)
Relay circuitRecommended Actions
Table 3
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Look for active codes that are associated with the system for the event code.
Codes
Result: An associated code is active.
Repair: Troubleshoot any associated codes before continuing with this test.
Result: An E955, E1589, 4367-1, 4367–7, 4367-17, 4367-18, or 4367-31 code is active.
Proceed to Test Step 4.
Result: An E951 (1) or 1761-17 code is active.
Proceed to Test Step 2.
2. Check the Remote Diesel Exhaust Fluid (DEF) Tank Level
A. Visually inspect the level of DEF in the Remote DEF tank.
DEF Level
Result: The remote DEF Tank level is not below the low DEF level switch.
Proceed to Test Step 3.
Result: The remote DEF tank level is below the low DEF level switch.
Repair: Add DEF to the remote DEF tank.
If the problem is not resolved, proceed to Test Step 3.
3. Check for Codes
A. Turn the DC breaker, located in the power distribution box, to the ON position.
B. Connect Cat ET.
C. Determine if a code is active or logged.
Codes
Result: An E951 (1) or 1761-17 code is logged.
Return to service.
Result: An E951 (1) or 1761-17 code is active.
Repair: There is a short to ground in the wiring harness between the remote DEF tank level switch and the Selective Catalyst Reduction (SCR) controller. Repair or replace the wiring harness.
Verify that the repair eliminated the problem.
4. Inspect the Remote Tank and Supply Lines
A. Turn the DC breaker, located in the power distribution box, to the OFF position.
B. Visually inspect the remote tank and all the DEF lines between the remote tank and buffer tank.
C. Inspect the lines to ensure that the lines are connected and routed properly.
DEF Lines
Result: The DEF supply line form the remote tank to the buffer tank are connected and routed properly.
Proceed to Test Step 5.
Result: The DEF supply lines from the remote tank to the buffer tank are not connected or routed properly.
Repair: Repair or replace the damaged DEF line.
If the problem is not resolved, proceed to Test Step 5.
5. Perform a "DEF Tank Refill Solenoid Override"
A. Turn the DC breaker, located in the power distribution box, to the ON position.
B. Connect Cat ET.
C. Use Cat ET to perform the following override:
- "DEF Tank Refill Solenoid Override"
D. Use Cat ET to monitor the following:
- "DEF Tank #2 Level"
Note: After the "DEF Tank #2 Level" reaches 90 percent, the override will automatically turn off.
DEF Level
Result: The "DEF Tank #2 Level" did not increase.
Proceed to Test Step 6.
Result: The "DEF Tank #2 Level" increased.
Verify that the repair eliminated the problem.
6. Replace the DEF Filter and clean the DEF filter screen.
Refer Illustration 2 to locate the filter and filter screen.
A. Replace the DEF filter between the remote tank and the dosing cabinet.
B. Clean or replace the DEF filter screen (6) at the DEF inlet of the dosing cabinet. If the DEF filter screen is damaged, replace the filter screen. Refer to Operation and Maintenance Manual,
Parts gear Volvo Penta:
851434
851434 Gear segment
AD30A; AQAD30A; MD30A, AQ175A, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A, AQ290A, MD31A; TMD31A; TMD31B, MD40A; TMD40A; TMD40B, TMD41A; TMD41B; D41A
897829
897829 Gear yoke
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ175A
832624
832624 Gear set
430; 430A; 430B, 500; 500A; 501A, 571A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ175A, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ205A; AQ205LB, AQ211A; DP-A; SP-A, AQ225D; AQ225E; AQ225F, AQ231A; AQ231B; A
832628
832628 Gear set
430; 430A; 430B, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, MD21B; AQD21B
832632
832632 Gear set
230A; 230B; 250A, 251A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ171A; AQ171C, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, MD21
818030
826708
818032