940186 Volvo.Penta Hexagon screw


940186 Hexagon screw Volvo.Penta 430; 430A; 430B, 500; 500A; 501A, 571A, AQ115A; AQ115B; AQ130, AQ175A, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ205A; AQ205LB, AQ211A; DP-A; SP-A, AQ225D; AQ225E; AQ225F, AQ231A; AQ231B; AQ231LB, AQ260A; AQ260B; Hexagon
940186 Hexagon screw Volvo Penta
Rating:
8

Buy Hexagon screw 940186 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$205.34
 

10-05-2020

-: -
Fidanza Performance 940186 Engine Timing Camshaft Gear Cam Gear Adjustable Ford/Mazda Red
$205.34
 

20-11-2019

-: -
Fidanza Performance 940186 Adjustable Cam Gears
$205.34
 

20-11-2019

-: -
Fidanza Performance 940186 Adjustable Cam Gears Red Engine Timing Camshaft Gear Cam Gear Adjustable Ford/Mazda Red
Number on catalog scheme: 24
 

Compatible models:

430; 430A; 430B   500; 500A; 501A   571A   AQ115A; AQ115B; AQ130   AQ175A   AQ190A; AQ240A   AQ200B; AQ225B   AQ200C; AQ200D; AQ225C   AQ200D; AQ200F; 280B   AQ205A; AQ205LB   AQ211A; DP-A; SP-A   AQ225D; AQ225E; AQ225F   AQ231A; AQ231B; AQ231LB   AQ260A; AQ260B; BB260A   AQ271A; AQ271B; AQ271C   AQ290A   AQ311A; AQ311B   AQD70D; TAMD70D; TAMD70E   BB231A; BB261A   D100A; D100AK; D100B   D100BHC; D100BRC; TD100AHC   D120A; D120AK; TD120A   D42A; D42A PP   D70B; D70B PP; D70B K   D70CHC; D70CRC; TD70CHC   DH10A; DH10A 285; DH10A 360   MB10A   MD100A; TMD100A; TMD100AK   MD120A; MD120AK; TMD120A   MD6; MD6A; MD6B   MD70B; MD70BK; TMD70B   MD70C; TMD70C; TAMD70C   TAD1030G; TD1010G; TWD1010G   TAD1030GE; TAD1031GE; TAD1032GE   TAD1030P   TAD1230G; TD1210G; TWD1210G   TAD1230P; TD121GP-87; TWD1210P   TAD1630P; TWD1630P; TWD1630PP   TAD1630V; TWD1630V   TAMD103A   TAMD122A; TMD122A; TAMD122P-A   TAMD60A; TAMD60B   TAMD60C   TD100CHC; TD100CRC; TD121CHC   TD100G-87; TD1030ME; TWD1030ME   TD100G-87; TD1030VE; TAD1030V   TD100G; TD100G-85; TD100G-87   TD120AHC; TD120ARC; TAD120AHC   TD120C   TD120HP-86; TD121; TD121G   TD120HPP; TID120HPP   TD121G-87; TWD1210V; TWD1211V   TD164KAE   TD30A; TD31ACE; TD40A   TD60A; TD60B; TD60B PP   TD60D; TD60D-83; TD60DPP-83   TD70G; TD70G-83; TD70GPP   TID120FPP; TID120FG; TD120G   TID121FG   TID162AG; TID162AGP; TID162AP   TMD100C   TMD102A; TAMD102A; TAMD102D   TMD121C; TAMD121C; TAMD121D   TWD1230ME   TWD1620G; TWD1630G; TAD1630G   Volvo.Penta

Volvo Penta entire parts catalog list:

430; 430A; 430B; 431A; 431B; 432A; 434A; 500B; 501B; 570A; 572A; 740B; DP-A; DP-A1; DP-A2; DP-C; DP-C1; DP-C1 1.95; DP-C1 2.30; DP-D; DP-D1; DP-D1
500; 500A; 501A
571A
AQ115A; AQ115B; AQ130; AQ130A; AQ130B; AQ130C; AQ130D; AQ165A; AQ170A; AQ170B; AQ170C; AQD21A; BB115A; BB115B; BB115C; BB165A; BB170A; BB170B; BB1
AQ175A
AQ190A; AQ240A
AQ200B; AQ225B
AQ200C; AQ200D; AQ225C; AQ225D; AQ255A; AQ255B
AQ200D; AQ200F; 280B; 290A; 290DP
AQ205A; AQ205LB
AQ211A; DP-A; SP-A; 290A
AQ225D; AQ225E; AQ225F; BB225A; BB225AV; BB225B; BB225C; 275; 280B; 290A; 290DP; MS3B; MS3C; MS4A
AQ231A; AQ231B; AQ231LB; 290A; DP-A; SP-A; 275A; 285A
AQ260A; AQ260B; BB260A; BB260AV; BB260B; BB260C
AQ271A; AQ271B; AQ271C; AQ271D; AQ271LB
AQ290A
AQ311A; AQ311B
AQD70D; TAMD70D; TAMD70E
BB231A; BB261A
D100A; D100AK; D100B; TD100A; TD100AG; TD100AK
D100BHC; D100BRC; TD100AHC; TD100ARC
D120A; D120AK; TD120A; TD120AG; TD120AG PP; TD120AK
D42A; D42A PP
D70B; D70B PP; D70B K; TD70B
D70CHC; D70CRC; TD70CHC; TD70CRC
DH10A; DH10A 285; DH10A 360; DH10A Rail; THD102KD; THD102KB
MB10A
MD100A; TMD100A; TMD100AK; TMD100A-CC; MD100B; MD100BK; MD100B-CC
MD120A; MD120AK; TMD120A; TMD120AK; TAMD120A; TAMD120AK; TMD120B; TAMD120B; TAMD120B-CC
MD6; MD6A; MD6B; MD7; MD7A; MD7B
MD70B; MD70BK; TMD70B; THAMD70B; TAMD70B; AQD70BL; AQD70B

Information:


Illustration 1 g00919872
Test Step 1. Check for Connector Damage.
Turn the battery disconnect switch to the OFF position.
Turn the keyswitch to the OFF position.
Thoroughly inspect the ECM connectors J1/P1 and J2/P2. Inspect all of the other connectors. Refer to the diagnostic functional test Troubleshooting, "Inspecting Electrical Connectors" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque of 6.0 N m (55 lb in).
Check the customer connector (allen head screw) for the proper torque of 2.25 0.25 N m (20 2 lb in).
Check the harness and the wiring for abrasion and for pinch points.Expected Result:The connectors and wiring should be free of the following problems: damage, corrosion, abrasion and incorrect attachment.Results:
OK - The connectors and wiring are okay. Proceed to test step 2.
Not OK - The connectors and/or wiring need repair.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Stop.Test Step 2. Check the ECM Supply Voltage.
Turn the battery disconnect switch to the ON position.
Turn the keyswitch to the ON position. The engine should be off.
Measure the voltage at the ECM connector between P1-4 and P1-11.Expected Result:The voltage should be 24 3 VDC.Results:
OK - The voltage is 24 3 VDC. The voltage is correct. Proceed to test step 3.
Not OK - The voltage is not 24 3 VDC. The voltage is incorrect.Repair: Perform the diagnostic functional test Troubleshooting, "Electrical Power Supply". Stop.Test Step 3. Check for Voltage at the Prelubrication Motor.
Turn the keyswitch to the OFF position.
Connect the Caterpillar Electronic Technician (ET) to the cab service tool connector J42. Start the Cat ET.
Connect a voltmeter between the positive terminal of the prelubrication motor and ground.
Turn the keyswitch to the ON position. The engine should be off.
Access the override for the prelubrication system.
Enable the override for the prelubrication system.
Measure the voltage between the positive terminal of the prelubrication motor and ground.Expected Result:The voltage should be 24 3 VDC.Results:
OK - The voltage is 24 3 VDC. Proceed to test step 4.
Not OK - The voltage is not 24 3 VDC. Proceed to test step 5.Test Step 4. Check the Operation of the Prelubrication Motor.
Turn the keyswitch to the OFF position.
Connect one side of a suitable piece of 10 AWG wire to the + Battery terminal.
For one second, connect the other end of the wire to the positive terminal of the prelubrication motor.Expected Result:The prelubrication motor should start while the wire is connected to the positive terminal of the prelubrication motor.Results:
OK - The prelubrication motor starts. There is a problem in the wiring harness at the prelubrication motor.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Stop.
Not OK - The prelubrication motor did not start.Repair: The problem appears to be in the prelubrication motor. Install a new prelubrication motor. If the condition is no longer present, reinstall the old prelubrication motor. If the original condition returns, replace the prelubrication motor. Stop.Test Step 5. Check the Output Voltage from the Primary Prelube Relay.
Connect a voltmeter between wire 337-WH on terminal 30 of the primary prelube relay and ground.
Turn the keyswitch to the ON position. The engine should be off.
Access the override for the prelubrication system.
Enable the override for the prelubrication system.
Measure the voltage between wire 337-WH on terminal 30 of the primary prelube relay and ground.Expected Result:The voltage should be 24 3 VDC.Results:
OK - The voltage is 24 3 VDC. Proceed to test step 6.
Not OK - The voltage is not 24 3 VDC. Proceed to test step 7.Test Step 6. Check the Voltage to the Coil of the Prelubrication Relay.
Connect a voltmeter between wire 337-WH on the prelubrication relay and ground.
Turn the keyswitch to the ON position. The engine should be off.
Access the override for the prelubrication system.
Enable the override for the prelubrication system.
Measure the voltage between wire 337-WH on the prelubrication relay and ground.Expected Result:The voltage should be 24 3 VDC.Results:
OK - The voltage is 24 3 VDC.Repair: Verify continuity of wire 200-BK between the prelubrication relay and ground. If the wire 200-BK is okay, verify that battery voltage is available to the normally open contacts of the prelubrication relay. If system voltage is available, replace the prelubrication relay. Stop.
Not OK - The voltage is not 24 3 VDC. There is a problem in the wiring harness between the prelubrication relay and the primary prelube relay.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Stop.Test Step 7. Check the Voltage to the Coil of the Primary Prelube Relay.
Connect a voltmeter between wire F709-BU on terminal 86 of the primary prelube relay and ground.
Turn the keyswitch to the ON position. The engine should be off.
Access the override for the prelubrication system.
Enable the override for the prelubrication system.
Measure the voltage between wire F709-BU on terminal 86 of the primary prelube relay and ground.Expected Result:The voltage should be 24 3 VDC.Results:
OK - The voltage is 24 3 VDC. Proceed to test step 8.
Not OK - The voltage is not 24 3 VDC. Proceed to test step 9.Test Step 8. Check the Voltage to the Contacts of the Primary Prelube Relay.
Connect a voltmeter between wire 150-RD on terminal 87 of the primary prelube relay and ground.
Turn the keyswitch to the ON position. The engine should be off.
Measure the voltage between wire 150-RD on terminal 87 of the primary prelube relay and ground.Expected Result:The voltage should be 24 3 VDC.Results:
OK - The voltage is 24 3 VDC.Repair: Verify continuity of wire 200-BK on terminal 85 between the primary prelube relay and ground. If the wire 200-BK is okay, install a new primary prelube relay. Verify that the prelubrication system is operating correctly. Stop.
Not OK - The voltage is not 24 3 VDC. There is a problem with the wiring harness between the primary prelube relay and the battery.Repair: Verify that the circuit breaker for


Parts hexagon Volvo Penta:

955523
Hexagon screw
955523 Hexagon screw
2001; 2001B; 2001AG, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ175A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C,
955270
 
955270 Hexagon screw
2001; 2001B; 2001AG, 430; 430A; 430B, 500; 500A; 501A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ14
955535
Hexagon screw
955535 Hexagon screw
430; 430A; 430B, 5.0GXi-A; 5.7Gi-A; 5.7GXi-A, 5.0GXi-B; 5.0GXi-BF; 5.0OSi-B, 5.7GLPMDA; 5.7GIPMDA; 5.7GIPMDACE, 5.7GLPNCS; 5.7GIPNCACE; 5.7GIPNCSCE, 500; 500A; 501A, 571A, 7.4GLPHUS; 7.4GIPHUSCE; 7.4GSIXHUS, 7.4GLPMDA; 7.4GLPMDM; 8.2GLPMDA, 7.4GLPNCA
955549
 
955549 Hexagon screw
AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, MD100A; TMD100A; TMD100AK, MD40A; TMD40A; TMD40B, TAD1030G; TD1010G; TWD1010G, TAD1030GE; TAD1031GE; TAD1032GE, TAD1030P, TAD1230G;
940092
Hexagon nut
940092 Hexagon nut
230A; 230B; 250A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ175A, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ23
959794
Hexagon screw
959794 Hexagon screw
430; 430A; 430B, 571A, AQ190A; AQ240A, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ211A; DP-A; SP-A, AQ225D; AQ225E; AQ225F, AQ231A; AQ231B; AQ231LB, AQ260A; AQ260B; BB260A, AQ271A; AQ271B; AQ271C, AQ290A, AQ311A; AQ311B, AQD70D; TAMD70D; TAMD70E
942268
Hexagon screw
942268 Hexagon screw
430; 430A; 430B, 500; 500A; 501A, 571A, AQ175A, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ205A; AQ205LB, AQ211A; DP-A; SP-A, AQ225D; AQ225E; AQ225F, AQ231A; AQ231B; AQ231LB, AQ260A; AQ260B; BB260A, AQ271A; AQ271B; AQ271C, AQ290A, AQ311A; AQ311B
959796
Hexagon screw
959796 Hexagon screw
430; 430A; 430B, AQ205A; AQ205LB, D120A; D120AK; TD120A, TAD1030G; TD1010G; TWD1010G, TAD1230G; TD1210G; TWD1210G, TAD1230P; TD121GP-87; TWD1210P, TAMD103A, TD100G-87; TD1030ME; TWD1030ME, TD100G-87; TD1030VE; TAD1030V, TD100G; TD100G-85; TD100G-87,
Back to top