961126 Volvo.Penta Hexagon nut


961126 Hexagon nut Volvo.Penta D120A; D120AK; TD120A, RAN181; RAN280; RAN480, TD120C Hexagon
961126 Hexagon nut Volvo Penta
Rating:
18

Buy Hexagon nut 961126 Volvo Penta genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$169.02
 

25-04-2024
0.2006[0.09] pounds
Amazon.com
TapeCase Copper Foil Tape with Acrylic Adhesive, Converted from 3M 1126, 6 yd Length, 9" Width, Roll
TapeCase Used for EMI/RFI shielding and cable wrap applications || Suitable for various electronic applications: static discharge draining, seaming shielded rooms, cable wrapping and surface contact to non-solderable materials || Conductive acrylic adhesive || Excellent solderability || 3M Preferred Converter: TapeCase is a 3M Preferred Converter; 3M has partnered with TapeCase to make their products available in a larger assortment of sizes, so that customers can use the tape in a variety of applications.
Number on catalog scheme: 9
 

Compatible models:

Volvo Penta entire parts catalog list:

D120A; D120AK; TD120A; TD120AG; TD120AG PP; TD120AK
RAN181; RAN280; RAN480; RAN480HD
TD120C

Information:


Illustration 1 g02766776
Typical view of the ECM
(1) J1/P1 ECM connector
(2) J2/P2 ECM connector The Electronic Control Module (ECM) has two connectors. The J1/P1 connector (1) is a 70-pin connector, while the J2/P2 connector (2) is a 120-pin connector. Each pin provides a connection point for a signal interface for the ECM.Overview of the Electronic Control System
The electronic control system is designed to control engine operation for optimum performance with minimal emissions.The ECM is the engine control computer for the engines electronic control system. The ECM provides the capacity for the input/output functions, the control functions, the data link communications, and the computational functionality for the system. This functionality is detailed below:Input/Output Functions
The ECM relies on several different types of input devices in order to gather information that is related to the current state of engine operation. The ECM receives the status information from the input devices and the ECM then uses the information to calculate the correct output action. This action is needed to control engine operation. These output actions are based on calculations that are made on cumulative data from other system components, software parameters, and information that is related to desired operation. The ECM utilizes switch inputs, sensor inputs, and data link communications to provide input information from the engine components.The ECM provides the following output functions:
Power supply control for related components
Controller circuits for engine operation
Communications ports for communication mediumThe ECM utilizes outputs as power supplies, outputs for high side ECM drivers (switch to battery circuits), outputs for low side ECM drivers (switch to ground circuits), and data link communications to output command signals to other engine controllers.Control Functions
Control functions are typically commands that are derived internally to the ECM circuitry. Control functions are used in order to calculate the necessary effect on the signal status for the output circuits that control the engine operation. The ECM utilizes the output drivers and data link communications to implement control over engine operation.Data Link Communications
The ECM uses the Can communication protocol for data link communications:This Data link is the main structure for communication between all of the controllers on the engine and on the machine.The CAN data link is used for communications between the engine ECM and controllers and displays that are on the engine and on the machine. The CAN data link may also be used for communications with Cat® Electronic Technician (ET).Computational Functionality
The computational functionality of the ECM is dedicated to all aspects of engine operation and engine monitoring. The ECM is continuously evaluating the engines current state of operation. The results are compared by the ECM to the engines desired state of operation. The ECM evaluates the difference between these two states in order to calculate the necessary control command signals. The ECM then modifies output signals in order to bring the current state of operation closer to the desired state of operation. The ECM also compares the current state of operation to an acceptable range of operation. If the status of any parameter is not within the acceptable range of operation, the ECM communicates the adverse condition to the operator.ECM Software
The ECM software is typically called a flash file. The flash file is a data file that is installed into the ECM. This data file provides the ECM with the software and the data that is needed to run the engine. Occasional updates to the flash file are provided by Caterpillar. The new software files can be downloaded from the Service Information System (SIS) web site. Use Cat ET to download the flash file to the ECM.


Parts hexagon Volvo Penta:

940162
Hexagon screw
940162 Hexagon screw
430; 430A; 430B, 500; 500A; 501A, 571A, AQ115A; AQ115B; AQ130, AQ175A, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ205A; AQ205LB, AQ211A; DP-A; SP-A, AQ225D; AQ225E; AQ225F, AQ231A; AQ231B; AQ231LB, AQ260A; AQ260B;
955536
Hexagon screw
955536 Hexagon screw
430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AQ115A; AQ115B; AQ130, AQ175A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ205A; AQ205LB, AQ211A; DP-A; SP-A, AQ225D; AQ225E; AQ225F, AQ231A; AQ231B; AQ231LB, AQ260A; AQ260B; B
955827
 
955827 Hexagon nut
430; 430A; 430B, 500; 500A; 501A, 571A, AQ115A; AQ115B; AQ130, AQ175A, AQ190A; AQ240A, AQ200C; AQ200D; AQ225C, AQ225D; AQ225E; AQ225F, AQ260A; AQ260B; BB260A, AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK;
955523
Hexagon screw
955523 Hexagon screw
2001; 2001B; 2001AG, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, AQ175A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C,
955779
 
955779 Hexagon nut
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B,
955270
 
955270 Hexagon screw
2001; 2001B; 2001AG, 430; 430A; 430B, 500; 500A; 501A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ14
955826
Hexagon nut
955826 Hexagon nut
2001; 2001B; 2001AG, 430; 430A; 430B, 500; 500A; 501A, 571A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ145A; BB145A, AQ175A, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ211A; DP-A; SP-
940092
Hexagon nut
940092 Hexagon nut
230A; 230B; 250A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ175A, AQ190A; AQ240A, AQ200B; AQ225B, AQ200C; AQ200D; AQ225C, AQ200D; AQ200F; 280B, AQ225D; AQ225E; AQ225F, AQ23
Back to top