Table 1
Diagnostic Codes for the Sensor Supply
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
3509-3 262-3 5 Volt Sensor DC Power Supply voltage above normal The Electronic Control Module (ECM) detects the following conditions:
The 5 V supply for the sensors is greater than 5.16 V for more than one second.
The ECM has been powered for at least 3 seconds.
Diagnostic code 168-3 is not active.
The ECM sets all of the sensors on the 5 V circuit to the default values.
The engine will be derated.
3509-4 262-4 5 Volt Sensor DC Power Supply voltage below normal The ECM detects the following conditions:
The 5 V supply for the sensors is less than 4.84 V for more than one second.
The ECM has been powered for at least 3 seconds.
Diagnostic code 168-4 is not active.
The ECM sets all of the sensors on the 5 V circuit to the default values.
The engine will be derated.
Follow the troubleshooting procedure in order to identify the root cause of the fault. The following background information is related to this procedure:The ECM supplies regulated +5 V to the following sensors:
Intake manifold air pressure sensor
Fuel pressure sensor
Engine oil pressure sensor
Primary speed/timing sensor
Secondary speed/timing sensorNote: Refer to the Electrical Schematic for the application for information regarding components that are connected to the 5 V supplies on the J1/P1 connector.A diagnostic code can be caused by the following conditions:
A short circuit in the harness
A short circuit to a voltage that is higher than 5.16 V
A faulty sensor
A faulty ECM
An open circuit in the harness
Illustration 1 g06403969
5 V supply circuit
Note: Refer to the Electrical Schematic for the application for information regarding components that are connected to the 5 V supplies on the J1/P1 connector.
Illustration 2 g06404281
P2 pin locations for the sensor circuits
(3) Fuel rail pressure sensor signal
(8) Intake manifold pressure sensor signal
(18) Oil pressure sensor signal
(36) Fuel rail pressure sensor supply
(58) Fuel rail pressure sensor return
(69) Oil pressure sensor/IMAP supply
(91) Oil pressure sensor/IMAP return
Illustration 3 g03374231
Fuel rail pressure sensor
(1) Ground
(2) Signal
(3) 5 V Supply
Illustration 4 g01170310
Typical example of an engine pressure sensor
(1) 5 V Supply
(2) Ground
(3) Signal
Illustration 5 g06404682
Typical example of a speed/timing sensor
(1) Signal
(2) Ground
(3) Sensor Supply
Table 2
Troubleshooting Test Steps Values Results
1. Determine the Code
A. Connect the electronic service tool to the service tool connector. Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Turn the keyswitch to the ON position.
C. Determine if a diagnostic trouble code is present.
Diagnostic Codes
Result: A -3 or -4 code is present.
Note which sensor supply has the active diagnostic code.
Proceed to Test Step 2.
2. Check for a Failed Sensor
A. Connect to the electronic service tool.
B. Turn the keyswitch to the ON position.
C. Disconnect a sensor on the suspect sensor supply circuit.
D. Monitor the electronic service tool while the sensor is disconnected to see if the active code changes to logged.
E. Connect the suspect sensor to the wiring harness
F. Repeat steps C through E for each sensor on the suspect sensor supply.
Note: Refer to the Electrical Schematic for the application for information regarding components that are connected to the 5 V supplies on the J1/P1 connector.
Failed Sensor
Result: The suspect sensor supply active code changes to logged when a sensor is unplugged.
Repair: Replace the failed sensor.
Verify that the repair resolved the problem.
Result: The suspect sensor supply active code remains active after all sensors on the sensor supply circuit have been checked.
Repair: A failed wiring harness has been detected. Repair or replace the wiring harness.
Verify that the repair resolved the problem.
If the procedure did not correct the fault, contact the Dealer Solutions Network (DSN).


Parts hose Volvo Penta:

943480
 
943480 Hose clamp
430; 430A; 430B, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, D12D-A MG; D12D-E MG, D16C-A MG, D3-110I-A; D3-110I-B; D3-110I-C, D42A; D4
952973
 
952973 Hose
430; 430A; 430B, 740A; BB740A, AQD70D; TAMD70D; TAMD70E, D100BHC; D100BRC; TD100AHC, D120A; D120AK; TD120A, D13B-E MH; D13B-E MH (FE); D13B-N MH, D16C-A MG, D9A2A; D9A2A MG; D9A2A D9A-MG, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD40A; TM
1674223
Hose clamp
1674223 Hose clamp
1372, D13B-A MP; D13B-B MP; D13B-C MP, D13B-E MH; D13B-E MH (FE); D13B-N MH, D13B-F MG; D13B-E MG; D13B-E MG (FE), D13C1-A MP; D13C2-A MP; D13C3-A MP, TAD1030GE; TAD1031GE; TAD1032GE, TAD1140VE; TAD1141VE; TAD1142VE, TAD1150VE; TAD1151VE; TAD1152VE,
949931
Hose
949931 Hose
1372, D13C1-A MP; D13C2-A MP; D13C3-A MP, TAD1140VE; TAD1141VE; TAD1142VE, TAD1150VE; TAD1151VE; TAD1152VE, TAD1170VE; TAD1171VE; TAD1172VE, TAD1340VE; TAD1341VE; TAD1342VE, TAD1341GE; TAD1342GE; TAD1343GE, TAD1350VE, TAD1351VE; TAD1352VE; TAD1353VE,
20435760
Hose clamp
20435760 Hose clamp
1372, D16C-A MG, D16C-A MH; D16C-B MH; D16C-C MH, D16C-D MH, D9A2A; D9A2A D9-425; D9A2A D9-500, D9A2A; D9A2A MG; D9A2A D9A-MG, TAD1030GE; TAD1031GE; TAD1032GE, TAD1240GE; TAD1241GE; TAD1242GE, TAD1340VE; TAD1341VE; TAD1342VE, TAD1341GE; TAD1342GE; TA
3885183
 
3885183 Hose connection
D16C-A MG, TAD1640GE; TAD1641GE; TAD1642GE
976923
 
976923 Hose nipple
1372, DH10A; DH10A 285; DH10A 360, TAD1340VE; TAD1341VE; TAD1342VE, TAD1350VE, TAD1351VE; TAD1352VE; TAD1353VE, TAD1352VE, TAD1360VE, TAD1361VE, TAD1363VE, TAD1371VE; TAD1372VE; TAD1373VE, TAD1641VE; TAD1642VE; TAD1643VE, TAD1643VE-B, TAD1650VE-B; TA
21618092
 
21618092 Hose, red
TAD1640GE; TAD1641GE; TAD1642GE
Back to top