813644 Hose attachment Volvo.Penta
AQD70D; TAMD70D; TAMD70E, D12D-A MH; D12D-B MH; D12D-C MH, D9A2A; D9A2A D9-425; D9A2A D9-500, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAMD103A, TAMD122A; TMD122A; TAMD122P-A, TAMD162A; TAMD1
Hose
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$25.95
01-12-2023
2.29[1.03] pounds
US: Race-Driven Inc
Sprocket for Honda Nighhawk 750 CB750SC 1982 1983 45T Rear by Race-Driven
Race-Driven Brand New 45 Tooth Rear Steel Sprocket || Race-Driven sprockets are manufactured to exceed OEM specifications || Race-driven sprockets are produced using hardened S45C steel || Fits: 1982 1983 Honda Nighhawk 750 CB750SC
Race-Driven Brand New 45 Tooth Rear Steel Sprocket || Race-Driven sprockets are manufactured to exceed OEM specifications || Race-driven sprockets are produced using hardened S45C steel || Fits: 1982 1983 Honda Nighhawk 750 CB750SC
Compatible models:
AQD70D; TAMD70D; TAMD70E
D12D-A MH; D12D-B MH; D12D-C MH
D9A2A; D9A2A D9-425; D9A2A D9-500
MD100A; TMD100A; TMD100AK
MD120A; MD120AK; TMD120A
MD70B; MD70BK; TMD70B
MD70C; TMD70C; TAMD70C
TAMD103A
TAMD122A; TMD122A; TAMD122P-A
TAMD162A; TAMD162B; TAMD162C
TAMD162C-C; TAMD163A-A; TAMD163P-A
TAMD165A; TAMD165C; TAMD165P
TAMD61A; TAMD62A
TAMD71A; TAMD72A
TMD100C
TMD102A; TAMD102A; TAMD102D
TMD121C; TAMD121C; TAMD121D
Volvo.Penta
Volvo Penta entire parts catalog list:
D12D-A MH; D12D-B MH; D12D-C MH; D12D-E MH; D12D-G MH; D12C-A MP; D12D-A MP; D12D-B MP; D12D-C MP; D12D-D MP; D12D-E MP; D12D-F MP; D12D-G M
D9A2A; D9A2A D9-425; D9A2A D9-500; D9A2A D9-500 (R4); D9A2A D9-575; D9A2B D9-425; D9A2B D9-500 (R5); D9A2B D9-575; D9A2C D9-425; D9A2D D9
MD100A; TMD100A; TMD100AK; TMD100A-CC; MD100B; MD100BK; MD100B-CC
MD120A; MD120AK; TMD120A; TMD120AK; TAMD120A; TAMD120AK; TMD120B; TAMD120B; TAMD120B-CC
MD70B; MD70BK; TMD70B; THAMD70B; TAMD70B; AQD70BL; AQD70B
- Keel Cooling System, Earlier Prod: A
- Keel Cooling System, Earlier Prod: A
- Keel Cooling System, Earlier Prod: B
TAMD103A
TAMD122A; TMD122A; TAMD122P-A; TAMD122P-B; TAMD122P-C; TMD122A/C; TAMD122AF
- Wet Exhaust Elbow 6'' (150mm)
- Wet Exhaust Line 7'' (175mm)
- Bilge Pump 2''
- Bilge Pump 2'', High Installation
- Flushing Pump 2''
- Wet Exhaust Line 7'' (175mm)
- Separately Mounted (Central-) Heat Exchanger: SN-1101042002/ XXXXX
- Separately Mounted (Central-) Heat Exchanger: SN 1101042003/ XXXXX-1101051030/XXXXX
- Bilge Pump 2''
- Flushing Pump 2''
TAMD165A; TAMD165C; TAMD165P; TAMD165A-A; TAMD165C-A; TAMD165P-A
- Wet Exhaust Line 7'' (175mm)
- Wet Exhaust Line 8'' (200mm)
- Bilge Pump 2''
- Flushing Pump 2''
TAMD71A; TAMD72A
TMD100C
- FLUSHING PUMP 2'' AND INSTALLATION INSTALLATION COMPONENTS
- BILGE PUMP 2'' AND INSTALLATION COMPONENTS
- Wet Exhaust Elbow 6'' 7''
- Bilge Pump 2''
- Bilge Pump 2'', High Installation
- Flushing Pump 2''
Information:
Engine Rating Parameter
Rating Number
The rating number is the selected rating within a power rating family. The flash file defines the power rating family. The flash file can contain one to four ratings. The rating number defines the power rating that is used within the power rating family.
Table 1
Minimum    Maximum    Default    
1     4     1    Low/High Idle Parameters
Low Idle Speed
The "Low Idle Speed" is the minimum engine rpm.
Table 2
Minimum    Maximum    Default    
700 rpm     1200 rpm     750 rpm    High Idle Speed
The "High Idle Speed" is the maximum engine rpm.
Table 3
Minimum    Maximum    Default    
1900 rpm     2900 rpm     2650 rpm    ECM Identification Parameter
Equipment ID
"Equipment ID" is the identification of the equipment that is assigned by the customer. The "Equipment ID" is only for reference by the customer. The "Equipment ID" is not required by the Electronic Control Module (ECM).
Table 4
Value    Default    
17 digits
The available characters are dependent on the service tool that is being used.     Not programmed    PTO and Throttle Lock Parameters
Throttle Lock Feature Installation Status
The "Throttle Lock Feature Installation Status" is used to turn on the throttle lock features. When this parameter is changed to "Installed", the "PTO engine Speed Setting", the "Throttle Lock Increment Speed Ramp Rate" and the "Throttle Lock Engine Set Speed Increment" parameters are active and the parameters can be programmed.
Table 5
Value    Default    
Not Installed
Installed     Not Installed    PTO Engine Speed Setting
The "PTO Engine Speed Setting" is the engine speed that is attained when the PTO switch is moved to the ON position. If the "PTO Engine Speed Setting" parameter is programmed, the feature is turned off. If the "PTO Engine Speed Setting" parameter is set to a value that is between "1" and the low idle speed, the parameter is set to the low idle speed value. If the "PTO Engine Speed Setting" parameter is set to a value that is higher than the high idle speed, the parameter is set to the high idle speed value.
Table 6
Minimum    Maximum    Default    
0 rpm     3000 rpm     0 rpm    Throttle Lock Increment Speed Ramp Rate
The "Throttle Lock Increment Speed Ramp Rate" is the rate of engine acceleration when the PTO switch is held in the ACCELERATE position. If this parameter is set to "0", the feature is turned off.
Table 7
Minimum    Maximum    Default    
0 rpm/sec     600 rpm/sec     400 rpm/sec    Throttle Lock Engine Set Speed Increment
The "Throttle Lock Engine Set Speed Increment" controls the increase in engine speed when the PTO switch is briefly operated to ACCELERATE or DECELERATE. If this parameter is set to "0", the feature is turned off.
Table 8
Minimum    Maximum    Default    
0 rpm     200 rpm     10 rpm    Miscellaneous
Monitoring Mode Shutdowns
"Monitoring Mode Shutdowns" controls the shutdown feature that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-3" suffix is detected, the engine will be shut down.
Table 9
Value    Default    
Disabled
Enabled     Disabled    Monitoring Mode Derates
"Monitoring Mode Derates" controls the derate that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-2" is detected, the engine will be derated.
Rating Number
The rating number is the selected rating within a power rating family. The flash file defines the power rating family. The flash file can contain one to four ratings. The rating number defines the power rating that is used within the power rating family.
Table 1
Minimum    Maximum    Default    
1     4     1    Low/High Idle Parameters
Low Idle Speed
The "Low Idle Speed" is the minimum engine rpm.
Table 2
Minimum    Maximum    Default    
700 rpm     1200 rpm     750 rpm    High Idle Speed
The "High Idle Speed" is the maximum engine rpm.
Table 3
Minimum    Maximum    Default    
1900 rpm     2900 rpm     2650 rpm    ECM Identification Parameter
Equipment ID
"Equipment ID" is the identification of the equipment that is assigned by the customer. The "Equipment ID" is only for reference by the customer. The "Equipment ID" is not required by the Electronic Control Module (ECM).
Table 4
Value    Default    
17 digits
The available characters are dependent on the service tool that is being used.     Not programmed    PTO and Throttle Lock Parameters
Throttle Lock Feature Installation Status
The "Throttle Lock Feature Installation Status" is used to turn on the throttle lock features. When this parameter is changed to "Installed", the "PTO engine Speed Setting", the "Throttle Lock Increment Speed Ramp Rate" and the "Throttle Lock Engine Set Speed Increment" parameters are active and the parameters can be programmed.
Table 5
Value    Default    
Not Installed
Installed     Not Installed    PTO Engine Speed Setting
The "PTO Engine Speed Setting" is the engine speed that is attained when the PTO switch is moved to the ON position. If the "PTO Engine Speed Setting" parameter is programmed, the feature is turned off. If the "PTO Engine Speed Setting" parameter is set to a value that is between "1" and the low idle speed, the parameter is set to the low idle speed value. If the "PTO Engine Speed Setting" parameter is set to a value that is higher than the high idle speed, the parameter is set to the high idle speed value.
Table 6
Minimum    Maximum    Default    
0 rpm     3000 rpm     0 rpm    Throttle Lock Increment Speed Ramp Rate
The "Throttle Lock Increment Speed Ramp Rate" is the rate of engine acceleration when the PTO switch is held in the ACCELERATE position. If this parameter is set to "0", the feature is turned off.
Table 7
Minimum    Maximum    Default    
0 rpm/sec     600 rpm/sec     400 rpm/sec    Throttle Lock Engine Set Speed Increment
The "Throttle Lock Engine Set Speed Increment" controls the increase in engine speed when the PTO switch is briefly operated to ACCELERATE or DECELERATE. If this parameter is set to "0", the feature is turned off.
Table 8
Minimum    Maximum    Default    
0 rpm     200 rpm     10 rpm    Miscellaneous
Monitoring Mode Shutdowns
"Monitoring Mode Shutdowns" controls the shutdown feature that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-3" suffix is detected, the engine will be shut down.
Table 9
Value    Default    
Disabled
Enabled     Disabled    Monitoring Mode Derates
"Monitoring Mode Derates" controls the derate that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-2" is detected, the engine will be derated.
Parts hose Volvo Penta:
185501
185501 Hose
2001; 2001B; 2001AG, 230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131C, AQ145A; BB145A, AQ145B, AQ151A; AQ151B; AQ151C, A
853012
853012 Hose clamp
230A; 230B; 250A, 251A, 430; 430A; 430B, 500; 500A; 501A, 571A, 740A; BB740A, AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQ120B; AQ125A; AQ140A, AQ125B, AQ131A; AQ131B; AQ131
943473
943473 Hose clamp
AD30A; AQAD30A; MD30A, AD31D; AD31D-A; AD31XD, AD31L-A; AD31P-A; AD41L-A, AD41D; D41D; TAMD41D, AQ115A; AQ115B; AQ130, AQD70D; TAMD70D; TAMD70E, D100A; D100AK; D100B, D12D-A MG; D12D-E MG, D3-110I-A; D3-110I-B; D3-110I-C, D42A; D42A PP, D5A-T; D5A-TA
961667
961667 Hose clamp
4.3GLMMDA; 4.3GLPMDA; 4.3GSPMDA, 4.3GLPBYC; 4.3GSPBYC; 4.3GIPBYCCE, 4.3GLPHUB; 4.3GSPHUB; 4.3GSPHUS, 4.3GLPLKD; 4.3GLPLKE; 4.3GSPLKD, 4.3GLPNCA; 4.3GLPNCB; 4.3GLPNCS, 430; 430A; 430B, 5.0FIPHUBCE; 5.0FIPHUCCE; 5.0FIPHUECE, 5.0FiPMDA; 5.0FiPMDM; 5.8Fi
821032
821032 Hose connection
AQD70D; TAMD70D; TAMD70E, MD70B; MD70BK; TMD70B, MD70C; TMD70C; TAMD70C, TAMD60A; TAMD60B, TAMD60C
842028
842028 Hose attachment
AQD70D; TAMD70D; TAMD70E, D100BHC; D100BRC; TD100AHC, MD100A; TMD100A; TMD100AK, MD120A; MD120AK; TMD120A, TAMD122A; TMD122A; TAMD122P-A, TAMD61A; TAMD62A, TAMD63L-A; TAMD63P-A, TAMD71A; TAMD72A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD74A; TAMD74A-A; TA
947502
947502 Hose nipple
D12D-A MH; D12D-B MH; D12D-C MH, TAD570VE; TAD571VE; TAD572VE, TAD870VE; TAD871VE; TAD872VE, TAMD60A; TAMD60B, TAMD60C, TAMD61A; TAMD62A, TAMD63L-A; TAMD63P-A, TAMD71A; TAMD72A, TAMD71B; TAMD73P-A; TAMD73WJ-A, TAMD72P-A; TAMD72WJ-A, TD30A; TD31ACE; T
8157557